Objectives Existing cardiovascular simulators are used to evaluate artificial organs such as artificial hearts, prosthetic valves,and artificial blood vessels, and pulses are typically triggered using artificial hearts. However, the forms of pulse waves vary according to the location of arteries, and for precise assessment of artificial blood vessels, the development of simulators that generate diverse pressure pulse waves is necessary. This study developed a novel cardiovascular simulator that generates different forms of pulse waves. Methods This simulator consists of a stepping motor, a slider–crank mechanism that transforms the rotation movement of a motor into the straight-line motion of a piston, a piston that generates pulsatile flows, a water tank that supplies fluids, an elastic tube made of silicon, and a device that adjusts the terminal resistance of fluids. Results & Conclusion This study examined motor rotation and its operation under conditions similar to the physiological conditions of the heart. The simulator developed in this study produced diverse forms of waves, and the generated pressure waves well satisfied physiological conditions.
Abstract
Objectives Existing cardiovascular simulators are used to evaluate artificial organs such as artificial hearts, prosthetic valves,and artificial blood vessels, and pulses are typically triggered using artificial hearts. However, the forms of pulse waves vary according to the location of arteries, and for precise assessment of artificial blood vessels, the development of simulators that generate diverse pressure pulse waves is necessary. This study developed a novel cardiovascular simulator that generates different forms of pulse waves. Methods This simulator consists of a stepping motor, a slider–crank mechanism that transforms the rotation movement of a motor into the straight-line motion of a piston, a piston that generates pulsatile flows, a water tank that supplies fluids, an elastic tube made of silicon, and a device that adjusts the terminal resistance of fluids. Results & Conclusion This study examined motor rotation and its operation under conditions similar to the physiological conditions of the heart. The simulator developed in this study produced diverse forms of waves, and the generated pressure waves well satisfied physiological conditions.
참고문헌 (11)
- 신상훈, "중국의 맥진 객관화 연구동향", 대한한의진단학회지, 8, pp.45~56 (2004)
- 강희정, "맥 진단기기의 요소기술 및 제품화동향", 전자공학회지, 37, pp.22~31 (2010)
- SH Shin, "Effects of changes in the physical properties of the central elastic artery on haemodynamic characteristics during ageing", JEIM, 223, pp.525~535 (2009)
- 신상훈, "심혈관 노화가 脈象에 미치는 영향", 대한한의진단학회지, 9, pp.59~68 (2005)
- Timms, D.L., "A complete mock circulation loop for the evaluation of left- right- and biventricular assist devices", Artificial Organs, 29, pp.564~571 (2005)
- Marx TI, "A cardiovascular simulator for the evaluation of prosthetic aortic valve", J. Thoracic and Cardiovas. Surg, 38, pp.412~418 (1959)
- Legendre D, "Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases", Artificial Organs, 32, pp.461~467 (2008)
- 이주연, "맥진연구를 위한 심혈관계 시뮬레이터의 개발", 대한한의진단학회지, 16(1), pp.19~26 (2012), 대한한의진단학회
- Kiechl S, "The natural course of atherosclerosis. Part II: vascular remodeling", Arteriosclerosis, Thrombosis, Vascular Biology, 19, pp.1491~1498 (1999)
- Franklin SS, "Hemodynamic Patterns of Age-Related Changes in Blood Pressure. The Framingham Heart Study", Circulation, 96, pp.308~315 (1997)
- Mitchell GF, "Changes in arterial stiffness and wave reflection with advancing age in healthy men and women: the Framingham heart study", Hypertension, 43, pp.1239~1245 (2004)