심혈관계 시뮬레이터의 연구동향
Review of Simulators for Cardiovascular System
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objectives The purpose of this study is to review the simulator for cardiovascular system. Methods & Results Simulators were classified according to the structure and function of cardiovascular system. Heart and blood vessel were selected as the represent of structure. Blood pressure and blood flow were chose as the functional index. With the view points of four keywords, four kinds of simulators were selected: artificial heart, pressure simulator, flow simulator, and pulse simulator. Conclusions This paper discussed the state of the art of research and development of the selected four kinds of simulators.
Abstract
Objectives The purpose of this study is to review the simulator for cardiovascular system. Methods & Results Simulators were classified according to the structure and function of cardiovascular system. Heart and blood vessel were selected as the represent of structure. Blood pressure and blood flow were chose as the functional index. With the view points of four keywords, four kinds of simulators were selected: artificial heart, pressure simulator, flow simulator, and pulse simulator. Conclusions This paper discussed the state of the art of research and development of the selected four kinds of simulators.
참고문헌 (22)
- 선경, "인공심장 연구의 최신동향", 보건산업기술동향, 30, pp.23~30 (2007)
- 김형묵, "인공심장", 대한의학협회지, 299, pp.1087~1090 (1984)
- 박찬영, "인공심장의 연구개발 현황", 한국정밀공학회지, 17, pp.5~16 (2000)
- Lietz K, "Will left-ventricular assistdevice therapy replace heart transplantation inthe foreseeable future", Curr Opin Cardiol, 20, pp.132~137 (2005)
- 최원우, "전류파형분석에 의한 완전이식 인공심장의 심박출량 자동제어 알고리즘", 한국자동제어학술회의논문집, pp.383~391 (1993)
- AAMI, "ANSI", AAMI SP10-1987: American nationalstandard for electronic or automatedsphygmomanometers, 1987
- O'Brien E, "The BritishHypertension Society protocol for the evaluationof automated and semi-automated bloodpressure measuring devices with special referenceto ambulatory systems", J Hypertens, 8, pp.607~619 (1990)
- Hochberg HM, "Automatic blood pressuremeasurement in multi-testing", InternationalHealth Evaluation Association, ~ (1971)
- Ng KG, "Review of methods & simulatorsfor evaluation of noninvasive bloodpressure monitors", J Clin Eng, 17, pp.469~479 (1992)
- Yong P, "A surrogate arm for evaluatingthe accuracy of instruments for indirectmeasurement of blood pressure", BiomedInstrum Technol, 24, pp.130~135 (1990)
- Wang M, "Development of K-sound and oscillometricpulse generating system for NIBP monitor tester", 석사, pp.1990
- Costello LF, "Oscillometric non-invasive bloodpressure simulator", US Patent 5027641, ~ (1991)
- 전세종, "혈류 시뮬레이터를 이용한 초음파 혈류계 교정에 대한 연구", 한국정밀공학회 추계학술대회논문집, pp.637~638 (2009)
- Liebert A, "A calibrationstandard for laser-Doppler perfusionmeasurements", Rev Sci Instrum, 66, pp.5169~5173 (1995)
- 고한우, "자기혼합형 LDF 프로브와 혈류시뮬레이터의 구현", 센서학회지, 8, pp.39~44 (1999)
- 陆小左, "脉图的简单判别", 天津中医学院学报, 22, pp.4~5 (2003)
- 汤伟昌, "中医脉象模拟系统的研究", 中国中医基础医学杂志, 6, pp.62~65 (2000)
- 김은근, "모의 맥파 재현 장치를 이용한 부침맥 구현", 대한전자공학회 하계종합학술대회, pp.1170~1171 (2009)
- Amoore JN, "Evaluation of theCritikon 8100 and Spacelabs 90207 non-invasiveblood pressure monitors using a testsimulator", J Hum Hypertens, 11, pp.163~169 (1997)
