심혈관계 시뮬레이터 개발 동향 분석을 통한 맥파검사용기기 성능평가 시뮬레이터 연구개발 방향 모색
A Study on the Direction of Developing a Simulator for Performance Evaluation of Pulse Wave Detectors Through a Review of the Development Status of Cardiovascular Simulators
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for per- formance evaluation of pulse wave detectors by identifying the development status of domestic and overseas car- diovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular sim- ulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance eval- uation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.
Abstract
In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for per- formance evaluation of pulse wave detectors by identifying the development status of domestic and overseas car- diovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular sim- ulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance eval- uation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.
참고문헌 (126)
- "2019년 사망원인통계 결과", 통계청, ~
- "Traditional Chinese medicine General require-ments of electric radial pulse tonometric devices", ~
- Rosenberg G, "Design and evaluation of the Pennsylvania State University mock circulatory system", ASAIO journal, 4(2), pp.41~49 (1981)
- "ISO 5840-1:2021 Cardiovascular implants - Cardiac valve prosthe-ses - Part 1: General requirements", ~
- Ferrari G, "Mock circula-tory system for in vitro reproduction of the left ventricle, the arterial tree and their interaction with a left ventricular assist device", Journal of medical engineering & technology, 18(3), pp.87~95 (1994)
- Yang TH, "심혈관계 시뮬레이터의 개발 동향", The Magazine of the IEIE, 43(12), pp.49~56 (2016)
- Liu Y, "Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing", Artificial organs, 29(4), pp.341~345 (2005)
- Timms D, "Evaluation of left ventric-ular assist device performance and hydraulic force in a complete mock circulation loop", Artificial organs, 29(7), pp.573~580 (2005)
- Uebelhart B, "Study of a centrifugal blood pump in a mock loop system", Artificial organs, 37(11), pp.946~949 (2013)
- Huang F, "A fast building and effective hydraulic pediatric mock circulatory system for the evaluation of a left ventricular assist device", ASAIO journal, 59(6), pp.575~585 (2013)
- Valdovinos J, "In Vitro Evaluation of an External Compression Device for F ontan Mechanical Assistance", Artificial organs, 38(3), pp.199~207 (2014)
- Pirbodaghi T, "Power consumption of rotary blood pumps : pulsatile versus constant-speed mode", Artificial Organs, 38(12), pp.1024~1028 (2014)
- Stephens AF, "In vitro evaluation of an immediate response Starling-like controller for dual rotary blood pumps", Artifi-cial Organs, 41(10), pp.911~922 (2017)
- Bark Jr DL, "Reynolds shear stress for textile prosthetic heart valves in relation to fabric design", Journal of the mechanical behavior of biomedical materials, 60, pp.280~287 (2016)
- Shehab S, "Right Ventricular Failure Post LVAD Implantation Corrected with Biventricular Support:An In-Vitro Model", The Journal of Heart and Lung Transplanta-tion, 35(4), pp.318~319 (2016)
- Pugovkin AA, "Advances in hemodynamic analysis in cardiovascular diseases investigation of energetic charac-teristics of adult and pediatric sputnik left ventricular assist devices during mock circulation support", Cardiology Research and Practice (2019)
- Kado Y, "The effects of preserving mitral valve function on a left atrial assist device: an in vitro mock circulation loop study", ASAIO Journal, 67(5), pp.567~572 (2020)
- Jurney PL, "Characterization of a pulsatile rotary total artificial heart", Artificial organs, 45(2), pp.135~ (2021)
- Wu Y, "A bridge from short-term to long-term left ventricular assist device—experimental verification of a physiological controller", Artificial organs, 28(10), pp.927~932 (2004)
- Pelletier BA, "Novel optical position sensing for miniaturized applications and validation in a total artificial heart", IEEE Transactions on Biomedical Engineering, 63(3), pp.478~484 (2015)
- Chung JH, "Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device (AnyHeart)", Journal of Biomedical Engineering Research, 22(5), pp.449~458 (2001)
- 강성민, "관형의 구조적 특징을 갖춘 박동형 관형 심실보조장치의 혈류, 혈압 평가", 대한기계학회논문집 B, 35(11), pp.1191~1198 (2011), 대한기계학회
- Vandenberghe S, "In vitro testing of a temporary catheter-based aortic “parachute”valve", ASAIO journal, 54(6), pp.574~577 (2008)
- Schampaert S, "In vitro comparison of support capabil-ities of intra?aortic balloon pump and Impella 2.5 left percu-taneous", Artificial Organs, 35(9), pp.893~901 (2011)
- Ismail M, "In vitro investigation of the hemodynamics of transcath-eter heterotopic valves implantation in the cavo-atrial junc-tion", Artificial Organs, 39(9), pp.803~814 (2015)
- Stock S, "Does undersizing of tran-scatheter aortic valve bioprostheses during valve-in-valve implanta-tion avoid coronary obstruction? An in vitro study", The Thoracic and Cardiovascular Surgeon, 65(03), pp.218~224 (2017)
- Sadri V, "In vitro evalua-tion of a new aortic valved conduit", The Journal of Thoracic and Cardiovascular Surgery, 161(2), pp.581~590 (2021)
- Loree HM, "In vitro study of a medical device to enhance arteriovenous fistula eligibility and maturation", ASAIO Journal, 61(4), pp.480~486 (2015)
- May-Newman K, "Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD", Artificial Organs, 43(9), pp.834~848 (2019)
- Ferrari G, "Experiments on dynamic behaviour of a Dacron aortic graft in a mock circulatory loop", Journal of biomechanics, 86, pp.132~140 (2019)
- Legerer C, "An experimental evaluation of a concept to improve conven-tional aortic prostheses", Journal of Biomechanics, 112, pp.110010~ (2020)
- Haiman G, "Reduction of Cerebral Emboli: In vitro Study with a Novel Cerebral Embolic Protection Device", Medical Devices, 13, pp.67~ (2020)
- 김수홍, "팔뚝형 자동혈압계 평가용 혈압 시뮬레이터 개발", 센서학회지, 24(4), pp.239~246 (2015), 한국센서학회[DOI]
- 도일, "자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발", 의공학회지, 38(3), pp.111~115 (2017), 대한의용생체공학회
- Jun MH, "Develop-ment of a tonometric sensor with a decoupled circular array for precisely measuring radial artery pulse", Sensors, 16(6), pp.768~ (2016)
- Rezaienia M A, "In-vitro investigation of the hemodynamic responses of the cerebral, coronary and renal circulations with a rotary blood pump installed in the descending aorta", Medical engineering & physics, 40, pp.2~10 (2017)
- Sunagawa G, "The contribution to hemody-namics even at very low pump speeds in the HVAD", The Annals of thoracic surgery, 101(6), pp.2260~2264 (2016)
- May-Newman K, "Mitral valve regurgitation in the LVAD-assisted heart studied in a mock circulatory loop", Cardiovascular engineering and technology, 7(2), pp.139~147 (2016)
- Kado Y, "Left atrial assist device func-tion at various heart rates using a mock circulation loop", The International Journal of Artificial Organs, 44(7), pp.465~470 (2021)
- Vandenberghe S, "Hemodynamic modes of ventricular assist with a rotary blood pump: continuous, pulsatile, and failure", Asaio Journal, 51(6), pp.711~718 (2005)
- Garcia MAZ, "The effect of aortic valve incompetence on the hemodynam-ics of a continuous flow ventricular assist device in a mock circulation", ASAIO journal, 54(3), pp.237~244 (2008)
- Shu F, "The importance of dQ", dt on the flow field in a turbodynamic pump with pulsatile flow, 2009, pp.33(9), 757~762
- Shiose A, "Speed modulation of the continuous-flow total artificial heart to simulate a physiologic arterial pressure waveform", ASAIO journal (American Society for Artificial Internal Organs: 1992), 56(5), pp.403~ (2010)
- Timms D, "Atrial versus ventricular cannulation for a rotary ventricular assist device", Artificial organs, 34(9), pp.714~720 (2010)
- Timms D, "Assessment of right pump outflow banding and speed changes on pulmonary hemodynamics during biventricular support with two rotary left ventricular assist devices", Artifi-cial organs, 35(8), pp.807~813 (2011)
- Timms D, "Assessment of right pump outflow banding and speed changes on pulmonary hemodynamics during biventricular support with two rotary left ventricular assist devices", Artifi-cial organs, 35(8), pp.807~813 (2011)
- Tolpen S, "Programmed speed reduction enables aortic valve opening and increased pulsatility in the LVAD-assisted heart", Asaio Journal, 61(5), pp.540~547 (2015)
- Shu F, "Classification of unsteady flow patterns in a rotodynamic blood pump: introduc-tion of non-dimensional regime map", Cardiovascular engi-neering and technolog, 6(3), pp.230~241 (2015)
- Sunagawa G, "In vitro hemodynamic char-acterization of HeartMate II at 6000 rpm: Implications for weaning and recovery", The Journal of thoracic and cardiovascu-lar surgery, 150(2), pp.343~348 (2015)
- Zhuang X, "Pump-ing rate study of a left ventricular assist device in a mock cir-culatory system", ASAIO Journal, 62(4), pp.410~420 (2016)
- Bozkurt S, "Enhancement of arterial pressure pulsatility by controlling continuous-flow left ven-tricular assist device flow rate in mock circulatory system", Jour-nal of Medical and Biological Engineering, 36(3), pp.308~315 (2016)
- Petrou A, "Response of a physiological controller for ventricular assist devices during acute patho-physiological events: an in vitro study", Biomedical Engineering, 2017, pp.62(6), 623~633
- Siewnicka A, "A model for estimating the blood flow of the POLVAD pulsatile ventricular assist device", IEEE Transactions on Biomedical Engineering, 65(11), pp.2552~2559 (2018)
- Ng BC, "Pulsatile operation of a continuous-flow right ventricular assist device (RVAD) to improve vascular pulsatility", PloS one, 13(4), pp.0195975~ (2018)
- Zhu S, "In vitro testing of an intra-ventricular assist device", Computer Assisted Surgery, 24(sup1), pp.89~95 (2019)
- Diedrich M, "Experimental investigation of right-left flow balance concepts for a total artificial heart", Artificial Organs, 45(4), pp.364~372 (2021)
- Tan SGD, "An in vitro investigation into the hemodynamic effects of orifice geom-etry and position on left ventricular vortex formation and tur-bulence intensity", Artificial Organs, 44(12), pp.520~531 (2020)
- Liu GM, "A 3-dimensional-printed left ventricle model incorporated into a mock circulatory loop to investigate hemodynamics inside a severely failing ventricle supported by a blood pump", Artificial Organs, 45(2), pp.143~150 (2021)
- Salaun E, "Effect of oversizing and elliptical shape of aortic annulus on transcatheter valve hemodynamics: An in vitro study", International journal of cardiology, 208, pp.28~35 (2016)
- Evin M, "Localized transvalvular pressure gradients in mitral bileaflet mechanical heart valves and impact on gradient overestima-tion by Doppler", Journal of the American Society of Echo-cardiography, 26(7), pp.791~800 (2013)
- Hartrumpf M, "The hemodynamic performance of standard bileaflet valveis impaired by a tilted implantation position", European jour-nal of cardio-thoracic surgery, 23(3), pp.283~291 (2003)
- Babin-Ebell J, "In-vitro hemodynamics of stented bio-prosthetic heart valves in the tilted implantation position", J Heart Valve Dis, 17(5), pp.566~570 (2008)
- Padala M, "Impact of mitral valve geometry on hemodynamic efficacy of surgical repair in secondary mitral regurgitation", J Heart Valve Dis, 23(1), pp.79~87 (2014)
- Midha PA, "Valve type, size, and deploy-ment location affect hemodynamics in an in vitro valve-in-valve model", JACC: Cardiovascular Interventions, 9(15), pp.1618~1628 (2016)
- Calderan J, "Development of an in vitro model to characterize the effects of transcatheter aortic valve on coronary artery flow", Artificial organs, 40(6), pp.612~619 (2016)
- Li CP, "Role of vortices in cavitation formation in the flow across a mechanical heart valve", The Journal of Heart Valve Disease, 17(4), pp.435~445 (2008)
- Padala M, "Mitral valve hemodynamics after repair of acute posterior leaflet prolapse: quadrangular resection ver-sus triangular resection versus neochordoplasty", The Journal of thoracic and cardiovascular surgery, 138(2), pp.309~315 (2009)
- Casa LD, "Impact of pulmonary hypertension on tricuspid valve function", Annals of biomedical engineering, 41(4), pp.709~724 (2013)
- Bark Jr DL, "Reynolds shear stress for textile prosthetic heart valves in relation to fabric design", Journal of the mechanical behavior of biomedical materials, 60, pp.280~287 (2016)
- Ismail M, "An experimental and computational study on the effect of caval valved stent oversizing", Cardio-vascular Engineering and Technology, 7(3), pp.254~269 (2016)
- Nguyen YN, "Experimental study of right ventricular hemody-namics after tricuspid valve replacement therapies to treat tri-cuspid regurgitation", Cardiovascular engineering and technology, 8(4), pp.401~418 (2017)
- McNally A, "Morphotype-dependent flow characteristics in bicuspid aortic valve ascending aortas: a benchtop particle image velocimetry study", Frontiers in physiol-ogy, 8, pp.44~ (2017)
- Geier A, "Influ-ence of cannulation site on carotid perfusion during extracor-poreal membrane oxygenation in a compliant human aortic model", Annals of biomedical engineering, 45(10), pp.2281~2297 (2017)
- Madukauwa-David ID, "An evaluation of the influence of coronary flow on transcatheter heart valve neo-sinus flow stasis", Annals of Biomedical Engineering, 48(1), pp.169~180 (2020)
- Cabrera Fischer EI, "Endothelium-dependent arterial wall tone elasticity modulated by blood viscosity", Amer-ican Journal of Physiology-Heart and Circulatory Physiology, 282(2), pp.389~394 (2002)
- Bia D, "Regional differences in viscosity, elasticity, and wall buffering function in systemic arteries: pulse wave analysis of the arterial pressure-diameter relationship", Revista Española de Cardiología(English Edition), 58(2), pp.167~174 (2005)
- Vukicevic M, "Mock circulatory system of the Fontan circulation to study respiration effects on venous flow behavior", ASAIO Journa, 59(3), pp.253~ (2013)
- Corazza, "Passive aortic counterpulsation: Biomechanical rationale and bench validation", Journal of Biomechanics, 47(7), pp.1618~1625 (2014)
- Vukicevic M, "Control of respiration-driven retrograde flow in the subdiaphragmatic venous return of the Fontan cir-culation", ASAIO journal, 60(4), pp.391~ (2014)
- Van Cauwenberge J, "Assessing the performance of ultrafast vector flow imaging in the neo-natal heart via multiphysics modeling and in vitro experiments", IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 63(11), pp.1772~1785 (2016)
- Van Cauwenberge J, "Assessing the performance of ultrafast vector flow imaging in the neo-natal heart via multiphysics modeling and in vitro experiments", IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 63(11), pp.1772~1785 (2016)
- Hatoum H, "Spatiotemporal complexity of the aortic sinus vortex as a function of leaflet calcification", Annals of biomedical engineering, 47(4), pp.1116~1128 (2019)
- Ding H, "Simulated coronary arterial hemodynamics of myocardial bridging", Reviews in Cardiovascular Medicine, 20(4) (2019)
- Legendre D, "Mock circulatory system for the evalua-tion of left ventricular assist devices, endoluminal prosthe-ses, and vascular diseases", Artificial organs, 32(6), pp.461~467 (2008)
- Zannoli R, "Mechanical simulator of the cardiovascular system", Physica Medica, 25(2), pp.94~100 (2009)
- Gwak KW, "Feedback linearization con-trol of a cardiovascular circulatory simulator", IEEE Transactions on Control Systems Technology, 23(5), pp.1970~1977 (2018)
- Gwak KW, "Nonlinear Adaptive Control of a Piston Pump Mock Ventricle", IEEE, 2015, pp.20(5), 2403~2412
- Arita M, "Multiple purpose simulator using a natural porcine mitral valve", Asian Cardio-vascular and Thoracic Annals, 12(4), pp.350~356 (2004)
- 곽관웅, "기계적 한계를 고려한 심혈관 순환계 임피던스 시뮬레이터 설계 및 평가", 한국정밀공학회지, 25(1), pp.151~159 (2008), 한국정밀공학회
- Pantalos GM, "Expanded pediatric cardiovascular simulator for research and training", ASAIO Journal, 56(1), pp.67~72 (2010)
- Gwak KW, "Experimental ver-ification of the feasibility of the cardiovascular impedance simulator", IEEE transactions on biomedical engineering, 57(5), pp.1176~1183 (2009)
- Schampaert S, "A mock circula-tion model for cardiovascular device evaluation", Physiologi-cal Measurement, 35(4), pp.687~ (2014)
- Rezaienia MA, "Numerical and in vitro investiga-tion of a novel mechanical circulatory support device installed in the descending aorta", Artificial organs, 39(6), pp.502~513 (2015)
- Gwak KW, "Model-Referenced Cardiovascular Circulatory Simulator: Construction and Control", Artificial Organs, 39(4), pp.309~318 (2015)
- Rezaienia MA, "In-vitro investigation of cerebral-perfusion effects of a rotary blood pump installed in the descending aorta", Journal of biomechanics, 49(9), pp.1865~1872 (2016)
- Piola M, "Design of a simple coronary impedance simu-lator for the in vitro study of the complex coronary hemody-namics", Physiological Measurement, 37(12), pp.2274~ (2016)
- Mueller I, "Design of a right ventricular mock circulation loop as a test bench for right ventricular assist devices", Biomedical Engineering, 2017, pp.62(2), 131~137
- Jansen-Park SH, "A mock heart engineered with helical aramid fibers for in vitro cardiovascular device testing", Biomedical Engineering, 2017, pp.62(2), 139~148
- 민수홍, "박동 혈액 순환 모의 시스템에서 시간 동기화된 혈압 및 혈액의 초음파 영상 측정 및 주기적 분석", 한국음향학회지, 36(5), pp.361~369 (2017), 한국음향학회[DOI]
- 류근택, "감압기를 이용한 동·정맥 침습적 혈압 시뮬레이터에 관한 연구", 전자공학회논문지, 55(12), pp.114~119 (2018), 대한전자공학회
- Petrou A, "A versatile hybrid mock circulation for hydraulic investigations of active and passive cardiovascular implants", Asaio Journal, 65(5), pp.495~ (2019)
- Papolla C, "Impact of mitral regurgitation on the flow in a model of a left ventricle", Car-diovascular Engineering and Technology, 11(6), pp.708~718 (2020)
- 이주연, "혈관계의 특성이 반영된 심혈관계 시뮬레이터의 개발", 대한한의진단학회지, 16(3), pp.33~40 (2012), 대한한의진단학회
- 이주연, "맥진연구를 위한 심혈관계 시뮬레이터의 개발", 대한한의진단학회지, 16(1), pp.19~26 (2012), 대한한의진단학회
- 이주연, "혈압파형에 초점을 맞춘 심혈관계 시뮬레이터의 개발", 의공학회지, 34(1), pp.40~45 (2013), 대한의용생체공학회[DOI]
- 이주연, "맥압조절이 가능한 맥파 연구용 심혈관계 시뮬레이터 개발", 전자공학회논문지, 51(10), pp.204~209 (2014), 대한전자공학회
- 이주연, "심혈관계 시뮬레이터를 이용한 맥파 반사지점 추정방법들의 비교", 대한한의진단학회지, 19(1), pp.47~54 (2015), 대한한의진단학회
- 정창진, "토노메트리 방식 맥파 측정의 가입 각도에 따른 변동성 평가", 센서학회지, 25(2), pp.138~142 (2016), 한국센서학회[DOI]
- Lee JY, "Study on the depth, rate, shape, and strength of pulse with cardiovascular simulator", Evidence-Based Complementary and Alternative Medicine (2017)
- Biglino G, "Using 4D cardiovascular magnetic resonance imaging to validate computational fluid dynam-ics: a case study", Frontiers in pediatrics, 3, pp.107~ (2015)
- Miyamoto T, "Simulated performance of the Cleveland Clinic continuous-flow total artificial heart using the Virtual Mock Loop", ASAIO journal (American Society for Artificial Internal Organs: 1992), 65(6), pp.565~ (2019)
- Padala M, "Hemodynamic comparison of mitral valve repair: tech-niques for a flail anterior leaflet", J Heart Valve Dis, 23(2), pp.171~176 (2014)
- Wong KC, "Effect of inflow cannula tip design on potential parameters of blood compatibility and thrombosis", Artificial Organs, 38(9), pp.810~817 (2014)
- Wong KC, "Effect of rotary blood pump pulsatility on potential parameters of blood compatibility and thrombosis in inflow cannula tips", The International Journal of Artificial Organs, 37(12), pp.875~887 (2014)
- Zhou J, "In vitro assessment of the assisted bidirec-tional Glenn procedure for stage one single ventricle repair", Cardiovascular engineering and technology, (3), pp.256~267 (2015)
- Hang T, "In vitro validation of a multiscale patient-specific Norwood Pallia-tion model", ASAIO Journal, 62(3), pp.317~324 (2016)
- Hirohashi Y, "Sensorless cardiac phase detection for synchronized control of ventricular assist devices using nonlinear kernel regression model", Journal of Artificial Organs, 9(2), pp.114~120 (2016)
- Kolyva C, "Newly shaped intra-aortic balloons improve the performance of counterpulsation at the semirecumbent position: an in vitro study", Artificial Organs, 40(8), pp.146~157 (2016)
- Geier A, "Influence of cannulation site on carotid perfusion during extracorporeal membrane oxygenation in a compliant human aortic model", Annals of biomedical engineering, 45(10), pp.2281~2297 (2017)
- Knoops PG, "A mock circulatory system incorporating a compliant 3D-printed anatomical model to investigate pul-monary hemodynamics", Artificial organs, 41(7), pp.637~646 (2017)
- Fanni BM, "A proof of concept of a non-invasive image-based material characterization method for enhanced patient-specific computational modeling", Cardiovascular Engineer-ing and Technology, 11(5), pp.532~543 (2020)
- Chen PC, "Engineering additive manufacturing and molding techniques to create lifelike willis’ circle simulators with aneurysms for training neurosurgeons", Polymers, 12(12), pp.2901~ (2020)
- Steinlauf S, "Aortic arch aneurysm repair–Unsteady hemodynamics and perfusion at different heart rates", Journal of Biomechanics, 121, pp.110351~ (2021)
- 고기영, "스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성", 방사선기술과학, 30(3), pp.205~212 (2007), 대한방사선과학회
- Bernal M, "Development and evaluation of anisotropic and nonlinear aortic models made from clinical images for in vitro experimentation", Physics in Medicine & Biology, 64(16), pp.165006~ (2019)
- Nicolaas W, "Snapshots of Hemodynamics 3rd Edition", pp.207~, Springer