본문 바로가기
KERD
논문KCI 등재

Effects of orthodontic mini-implant position in the dragon helix appliance on tooth displacement and stress distribution: a three-dimensional finite element analysis

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: The purpose of this study was to investigate the stress distribution on the orthodontic mini-implant (OMI) surface and periodontal ligament of the maxillary first and second molars as well as the tooth displacement according to the OMI position in the dragon helix appliance during scissors-bite correction. Methods: OMIs were placed at two maxillary positions, between the first and the second premolars (group 1) and between the second premolar and the first molar (group 2). The stress distribution area (SDA) was analyzed by three-dimensional finite element analysis. Results: The maximal SDA of the OMI did not differ between the groups. It was located at the cervical area and palatal root apex of the maxillary first molar in groups 1 and 2, respectively, indicating less tipping in group 2. The minimal SDA was located at the root and furcation area of the maxillary second molar in groups 1 and 2, respectively, indicating greater palatal crown displacement in group 2. Conclusions: Placement of the OMI between the maxillary second premolar and the maxillary first molar to serve as an indirect anchor in the dragon helix appliance minimizes anchorage loss while maximizing the effect on scissors-bite correction.

Abstract

Objective: The purpose of this study was to investigate the stress distribution on the orthodontic mini-implant (OMI) surface and periodontal ligament of the maxillary first and second molars as well as the tooth displacement according to the OMI position in the dragon helix appliance during scissors-bite correction. Methods: OMIs were placed at two maxillary positions, between the first and the second premolars (group 1) and between the second premolar and the first molar (group 2). The stress distribution area (SDA) was analyzed by three-dimensional finite element analysis. Results: The maximal SDA of the OMI did not differ between the groups. It was located at the cervical area and palatal root apex of the maxillary first molar in groups 1 and 2, respectively, indicating less tipping in group 2. The minimal SDA was located at the root and furcation area of the maxillary second molar in groups 1 and 2, respectively, indicating greater palatal crown displacement in group 2. Conclusions: Placement of the OMI between the maxillary second premolar and the maxillary first molar to serve as an indirect anchor in the dragon helix appliance minimizes anchorage loss while maximizing the effect on scissors-bite correction.

참고문헌 (23)

  1. "Scissors-bite correction on second molar with a dragon helix appliance", AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 132, pp.842~847
  2. Harper DL, "A case report of a Brodie bite", Am J Orthod Dentofacial Orthop, 108, pp.201~206 (1995)
  3. Orton-Gibbs S, "Eruption of third permanent molars after the extraction of second permanent molars. Part 2: Functional occlusion and periodontal status", Am J Orthod Dentofacial Orthop, 119, pp.239~244 (2001)
  4. Ramsay DS, "Case report MM. Surgical-orthodontic correction of bilateral buccal crossbite (Brodie syndrome)", Angle Orthod, 60, pp.305~311 (1990)
  5. Kucher G, "Goal-oriented positioning of upper second molars using the palatal intrusion technique", Am J Orthod Dentofacial Orthop, 110, pp.466~468 (1996)
  6. Chun YS, "Maxillary molar intrusion with the molar intrusion arch", J Clin Orthod, 34, pp.90~93 (2000)
  7. Legan HL, "Orthodontic planning and biomechanics for transverse distraction osteogenesis", Semin Orthod, 7, pp.160~168 (2001)
  8. Park YC, "Intrusion of posterior teeth using mini-screw implants", Am J Orthod Dentofacial Orthop, 123, pp.690~694 (2003)
  9. Kanomi R, "Mini-implant for orthodontic anchorage", J Clin Orthod, 31, pp.763~767 (1997)
  10. Cope JB, "Temporary anchorage devices in orthodontics: a paradigm shift", Semin Orthod, 11, pp.3~9 (2005)
  11. Celenza F, "Absolute anchorage in orthodontics: direct and indirect implant-assisted modalities", J Clin Orthod, 34, pp.397~402 (2000)
  12. Kyung SH, "Bonding orthodontic attachments to miniscrew heads", J Clin Orthod, 39, pp.348~353 (2005)
  13. Kyung SH, "The use of miniscrew as an anchorage for the orthodontic tooth movement", Korean J Orthod, 31, pp.415~424 (2001)
  14. Bae SM, "Clinical application of micro-implant anchorage", J Clin Orthod, 36, pp.298~302 (2002)
  15. Park HS, "Uprighting second molars with micro-implant anchorage", J Clin Orthod, 38, pp.100~103 (2004)
  16. Park HS, "Orthodontic treatment using micro-implant. 2nd ed", pp.1~414 (2006), Seoul: Daehan Narae Publishing Inc
  17. Wilmes B, "Insertion angle impact on primary stability of orthodontic mini-implants", Angle Orthod, 78, pp.1065~1070 (2008)
  18. Lee KJ, "Computed tomographic analysis of tooth-bearing alveolar bone for orthodontic miniscrew placement", Am J Orthod Dentofacial Orthop, 135, pp.486~494 (2009)
  19. 임주은, "하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구", 대한치과교정학회지, 38(6), pp.397~406 (2008), 대한치과교정학회
  20. 박효상, "CT 이미지를 사용한 Micro-implants 식립을 위한 해부학적 연구", 대한치과교정학회지, 32(6), pp.435~441 (2002), 대한치과교정학회
  21. 김찬년, "골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석", 대한치과교정학회지, 33(5), pp.339~350 (2003), 대한치과교정학회
  22. Cheon OJ, "Three-dimentional finite element analysis of the phenomenon produced during retraction of four maxillary incisors", Korean J Orthod, 25, pp.525~541 (1995)
  23. 윤현주, "상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구", 대한치과교정학회지, 35(2), pp.137~147 (2005), 대한치과교정학회

관련 논문AI추천

Effects of the Angulation of Orthodontic Mini-Implant as an Indirect Anchorage : A Three-Dimensional Finite Element Analysis김민지, 박선형, 박영진, 전윤식대한턱관절교합학회 · 구강회복응용과학지2011 · 제27권 제3호Effect of bite force on orthodontic mini-implants in the molar region: Finite element analysis김민지, 전윤식, Hyeon-Jung Lee, Kyung-Sook Lee대한치과교정학회 · 대한치과교정학회지2013 · 제43권 제5호Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position모성서, Jae-Won Song, Joong-Ki Lim, Kee-Joon Lee, Sang-Jin Sung, Youn-Sic Chun대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제4호Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length김성훈, 정규림, Bohm Choi, Dong-Ok Lee, Gerald Nelson, Ki-Ho Park, Seong Ho Han, Sung-Seo Mo대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제6호Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles이기준, 황충주, Sang-Jin Sung, Seong-Jin Kim, Sung-Hwan Choi, Youn-Sic Chun대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제4호Biomechanical analysis of distalization of mandibular molars by placing a mini-plate: A finite element study나영현, 박명순, 박민봉, 안장훈대한치과교정학회 · 대한치과교정학회지2017 · 제47권 제5호

이 간행물의 다른 논문 (6건)