Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Objective: The purpose of this study was to analyze stress distributions in the roots, periodontal ligaments (PDLs), and bones around cylindrical and tapered miniscrews inserted at different angles using a finite element analysis. Methods: We created a three-dimensional (3D) maxilla model of a dentition with extracted first premolars and used 2 types of miniscrews (tapered and cylindrical) with 1.45-mm diameters and 8-mm lengths. The miniscrews were inserted at 30o, 60o, and 90o angles with respect to the bone surface. A simulated horizontal orthodontic force of 2 N was applied to the miniscrew heads. Then, the stress distributions, magnitudes during miniscrew placement, and force applications were analyzed with a 3D finite element analysis. Results: Stresses were primarily absorbed by cortical bone. Moreover, very little stress was transmitted to the roots, PDLs, and cancellous bone. During cylindrical miniscrew insertion, the maximum von Mises stress increased as insertion angle decreased. Tapered miniscrews exhibited greater maximum von Mises stress than cylindrical miniscrews. During force application, maximum von Mises stresses increased in both groups as insertion angles decreased. Conclusions: For both cylindrical and tapered miniscrew designs, placement as perpendicular to the bone surface as possible is recommended to reduce stress in the surrounding bone. [Korean J Orthod 2016;46(4):189-198]
Abstract
Objective: The purpose of this study was to analyze stress distributions in the roots, periodontal ligaments (PDLs), and bones around cylindrical and tapered miniscrews inserted at different angles using a finite element analysis. Methods: We created a three-dimensional (3D) maxilla model of a dentition with extracted first premolars and used 2 types of miniscrews (tapered and cylindrical) with 1.45-mm diameters and 8-mm lengths. The miniscrews were inserted at 30o, 60o, and 90o angles with respect to the bone surface. A simulated horizontal orthodontic force of 2 N was applied to the miniscrew heads. Then, the stress distributions, magnitudes during miniscrew placement, and force applications were analyzed with a 3D finite element analysis. Results: Stresses were primarily absorbed by cortical bone. Moreover, very little stress was transmitted to the roots, PDLs, and cancellous bone. During cylindrical miniscrew insertion, the maximum von Mises stress increased as insertion angle decreased. Tapered miniscrews exhibited greater maximum von Mises stress than cylindrical miniscrews. During force application, maximum von Mises stresses increased in both groups as insertion angles decreased. Conclusions: For both cylindrical and tapered miniscrew designs, placement as perpendicular to the bone surface as possible is recommended to reduce stress in the surrounding bone. [Korean J Orthod 2016;46(4):189-198]
참고문헌 (32)
- Reynders R, "Mini-implants in orthodontics: a systematic review of the literature", Am J Orthod Dentofacial Orthop, 135, pp.564.e1~564.e19 (2009)
- Cha JY, "Strain of bone-implant interface and insertion torque regarding different miniscrew thread designs using an artificial bone model", Eur J Orthod, 37, pp.268~274 (2015)
- Miyawaki S, "Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 124, pp.373~378 (2003)
- Cheng SJ, "A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage", Int J Oral Maxillofac Implants, 19, pp.100~106 (2004)
- Park HS, "Factors affecting the clinical success of screw implants used as orthodontic anchorage", Am J Orthod Dentofacial Orthop, 130, pp.18~25 (2006)
- Papadopoulos MA, "Clinical effectiveness of orthodontic miniscrew implants: a meta-analysis", J Dent Res, 90, pp.969~976 (2011)
- Cha JY, "The effect of miniscrew taper morphology on insertion and removal torque in dogs", Int J Oral Maxillofac Implants, 25, pp.777~783 (2010)
- Višnja Katić, "Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque", 대한치과교정학회지, 44(4), pp.177~183 (2014), 대한치과교정학회
- Lim SA, "Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length", Angle Orthod, 78, pp.234~240 (2008)
- Choi SH, "Surface changes of anodic oxidized orthodontic titanium miniscrew", Angle Orthod, 82, pp.522~528 (2012)
- Young-Chae Cho, "Biologic stability of plasma ion-implanted miniscrews", 대한치과교정학회지, 43(3), pp.120~126 (2013), 대한치과교정학회
- Motoyoshi M, "The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone", Int J Oral Maxillofac Surg, 38, pp.13~18 (2009)
- 김정훈, "Evaluation of mandibular cortical bone thickness for placement of temporary anchorage devices (TADs)", 대한치과교정학회지, 42(3), pp.110~117 (2012), 대한치과교정학회[DOI]
- 김정식, "Comparison of success rates of orthodontic mini-screws by the insertion method", 대한치과교정학회지, 42(5), pp.242~248 (2012), 대한치과교정학회
- Jasmine MI, "Analysis of stress in bone and microimplants during enmasse retraction of maxillary and mandibular anterior teeth with different insertion angulations:a 3-dimensional finite element analysis study", Am J Orthod Dentofacial Orthop, 141, pp.71~80 (2012)
- Perillo L, "Finite element analysis of miniscrew placement in mandibular alveolar bone with varied angulations", Eur J Orthod, 37, pp.56~59 (2015)
- Kyung HM, "Development of orthodontic micro-implants for intraoral anchorage", J Clin Orthod, 37, pp.321~328 (2003)
- Zhao L, "Effect of placement angle on the stability of loaded titanium microscrews: a microcomputed tomographic and biomechanical analysis", Am J Orthod Dentofacial Orthop, 139, pp.628~635 (2011)
- Wilmes B, "Insertion angle impact on primary stability of orthodontic mini-implants", Angle Orthod, 78, pp.1065~1070 (2008)
- Woodall N, "Effect of miniscrew angulation on anchorage resistance", Am J Orthod Dentofacial Orthop, 139, pp.e147~e152 (2011)
- Andrews LF, "The six keys to normal occlusion", Am J Orthod, 62, pp.296~309 (1972)
- Kronfeld R, "Histologic study of the influence of function on the human periodontal membrane", J Am Dent Assoc, 18, pp.1242~1274 (1931)
- Coolidge E, "The thickness of the human periodontal membrane", J Am Dent Assoc, 24, pp.1260~1270 (1937)
- Tominaga JY, "Effect of bracket slot and archwire dimensions on anterior tooth movement during space closure in sliding mechanics: a 3-dimensional finite element study", Am J Orthod Dentofacial Orthop, 146, pp.166~174 (2014)
- Reimann S, "Biomechanical finite-element investigation of the position of the centre of resistance of the upper incisors", Eur J Orthod, 29, pp.219~224 (2007)
- Ammar HH, "Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement", Am J Orthod Dentofacial Orthop, 139, pp.e59~e71 (2011)
- Liu TC, "Finite element analysis of miniscrew implants used for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 141, pp.468~476 (2012)
- Yoo SH, "A comparison of tapered and cylindrical miniscrew stability", Eur J Orthod, 36, pp.557~562 (2014)
- Ueda M, "Relationship between insertion torque and removal torque analyzed in fresh temporal bone", Int J Oral Maxillofac Implants, 6, pp.442~447 (1991)
- Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
- Deguchi T, "Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants", Am J Orthod Dentofacial Orthop, 129, pp.721.e7~721.e12 (2006)
- Lin TS, "Factorial analysis of variables affecting bone stress adjacent to the orthodontic anchorage mini-implant with finite element analysis", Am J Orthod Dentofacial Orthop, 143, pp.182~189 (2013)
