본문 바로가기
KERD
논문KCI 등재

Effect of bite force on orthodontic mini-implants in the molar region: Finite element analysis

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: To examine the effect of bite force on the displacement and stress distribution of orthodontic mini-implants (OMIs) in the molar region according to placement site, insertion angle, and loading direction. Methods: Five finite element models were created using micro-computed tomography (microCT) images of the maxilla and mandible. OMIs were placed at one maxillary and two mandibular positions: between the maxillary second premolar and first molar, between the mandibular second premolar and first molar, and between the mandibular first and second molars. The OMIs were inserted at angles of 45° and 90° to the buccal surface of the cortical bone. A bite force of 25 kg was applied to the 10 occlusal contact points of the second premolar, first molar, and second molar. The loading directions were 0°, 5°, and 10° to the long axis of the tooth. Results: With regard to placement site, the displacement and stress were greatest for the OMI placed between the mandibular first molar and second molar, and smallest for the OMI placed between the maxillary second premolar and first molar. In the mandibular molar region, the angled OMI showed slightly less displacement than the OMI placed at 90°. The maximum Von Mises stress increased with the inclination of the loading direction. Conclusions: These results suggest that placement of OMIs between the second premolar and first molar at 45° to the cortical bone reduces the effect of bite force on OMIs.

Abstract

Objective: To examine the effect of bite force on the displacement and stress distribution of orthodontic mini-implants (OMIs) in the molar region according to placement site, insertion angle, and loading direction. Methods: Five finite element models were created using micro-computed tomography (microCT) images of the maxilla and mandible. OMIs were placed at one maxillary and two mandibular positions: between the maxillary second premolar and first molar, between the mandibular second premolar and first molar, and between the mandibular first and second molars. The OMIs were inserted at angles of 45° and 90° to the buccal surface of the cortical bone. A bite force of 25 kg was applied to the 10 occlusal contact points of the second premolar, first molar, and second molar. The loading directions were 0°, 5°, and 10° to the long axis of the tooth. Results: With regard to placement site, the displacement and stress were greatest for the OMI placed between the mandibular first molar and second molar, and smallest for the OMI placed between the maxillary second premolar and first molar. In the mandibular molar region, the angled OMI showed slightly less displacement than the OMI placed at 90°. The maximum Von Mises stress increased with the inclination of the loading direction. Conclusions: These results suggest that placement of OMIs between the second premolar and first molar at 45° to the cortical bone reduces the effect of bite force on OMIs.

참고문헌 (29)

  1. Kanomi R, "Mini-implant for orthodontic anchorage", J Clin Orthod, 31, pp.763~767 (1997)
  2. Bae SM, "Clinical application of micro-implant anchorage", J Clin Orthod, 36, pp.298~302 (2002)
  3. Miyawaki S, "Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 124, pp.373~378 (2003)
  4. Cheng SJ, "A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage", Int J Oral Maxillofac Implants, 19, pp.100~106 (2004)
  5. Lim HJ, "Factors associated with initial stability of miniscrews for orthodontic treatment", Am J Orthod Dentofacial Orthop, 136, pp.236~242 (2009)
  6. Kuroda S, "Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort", Am J Orthod Dentofacial Orthop, 131, pp.9~15 (2007)
  7. Deguchi T, "The use of small titanium screws for orthodontic anchorage", J Dent Res, 82, pp.377~381 (2003)
  8. Chen YJ, "A retrospective analysis of the failure rate of three different orthodontic skeletal anchorage systems", Clin Oral Implants Res, 18, pp.768~775 (2007)
  9. Motoyoshi M, "Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants", Int J Oral Maxillofac Implants, 22, pp.779~784 (2007)
  10. Kuroda S, "Root proximity is a major factor for screw failure in orthodontic anchorage", Am J Orthod Dentofacial Orthop, 131, pp.S68~S73 (2007)
  11. Cattaneo PM, "The transfer of occlusal forces through the maxillary molars: a finite element study", Am J Orthod Dentofacial Orthop, 123, pp.367~373 (2003)
  12. Tanne K, "Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces", Am J Orthod Dentofacial Orthop, 92, pp.499~505 (1987)
  13. Miyaura K, "Rehabilitation of biting abilities in patients with different types of dental prostheses", J Oral Rehabil, 27, pp.1073~1076 (2000)
  14. Molly L, "Bone density and primary stability in implant therapy", Clin Oral Implants Res, 17(Suppl 2), pp.124~135 (2006)
  15. Javed F, "The role of primary stability for successful immediate loading of dental implants. A literature review", J Dent, 38, pp.612~620 (2010)
  16. Provatidis CG, "A comparative FEM-study of tooth mobility using isotropic and anisotropic models of the periodontal ligament. Finite Element Method", Med Eng Phys, 22, pp.359~370 (2000)
  17. Qian H, "The influence of PDL principal fibers in a 3-dimensional analysis of orthodontic tooth movement", Am J Orthod Dentofacial Orthop, 120, pp.272~279 (2001)
  18. Toms SR, "A nonlinear finite element analysis of the periodontal ligament under orthodontic tooth loading", Am J Orthod Dentofacial Orthop, 123, pp.657~665 (2003)
  19. Farnsworth D, "Cortical bone thickness at common miniscrew implant placement sites", Am J Orthod Dentofacial Orthop, 139, pp.495~503 (2011)
  20. Motoyoshi M, "Bone stress for a mini-implant close to the roots of adjacent teeth- 3D finite element analysis", Int J Oral Maxillofac Surg, 38, pp.363~368 (2009)
  21. Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
  22. 변나영, "교정용 미니임플랜트의 직경 및 식립각도에 따른 응력 분포에 관한 3차원 유한요소 분석", 대한치과교정학회지, 36(3), pp.178~187 (2006), 대한치과교정학회
  23. 이남기, "미니플레이트의 골내 고정원 적용 시 초기 안정성에 영향을 주는 요인에 대한 3차원 유한요소법적 연구", 대한치과교정학회지, 38(5), pp.304~313 (2008), 대한치과교정학회
  24. Sugiura T, "Evaluation of threshold stress for bone resorption around screws based on in vivo strain measurement of miniplate", J Musculoskelet Neuronal Interact, 1, pp.165~170 (2000)
  25. Li J, "A mathematical model for simulating the bone remodeling process under mechanical stimulus", Dent Mater, 23, pp.1073~1078 (2007)
  26. Canabarro Sde A, "Medial mandibular flexure and maximum occlusal force in dentate adults", Int J Prosthodont, 19, pp.177~182 (2006)
  27. Goodkind RJ, "Mandibular flexure in opening and closing movements", J Prosthet Dent, 30, pp.134~138 (1973)
  28. Korioth TW, "Deformation of the human mandible during simulated tooth clenching", J Dent Res, 73, pp.56~66 (1994)
  29. 윤현주, "상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구", 대한치과교정학회지, 35(2), pp.137~147 (2005), 대한치과교정학회

관련 논문AI추천

Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability문윤식, 백선혜, 성상진, 차정열, 차현석대한치과교정학회 · 대한치과교정학회지2012 · 제42권 제4호Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length김성훈, 정규림, Bohm Choi, Dong-Ok Lee, Gerald Nelson, Ki-Ho Park, Seong Ho Han, Sung-Seo Mo대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제6호Effects of the Angulation of Orthodontic Mini-Implant as an Indirect Anchorage : A Three-Dimensional Finite Element Analysis김민지, 박선형, 박영진, 전윤식대한턱관절교합학회 · 구강회복응용과학지2011 · 제27권 제3호Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles이기준, 황충주, Sang-Jin Sung, Seong-Jin Kim, Sung-Hwan Choi, Youn-Sic Chun대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제4호Effects of orthodontic mini-implant position in the dragon helix appliance on tooth displacement and stress distribution: a three-dimensional finite element analysis김민지, 김현성, 모성서, 박선형, 성상진, 장강원, 전윤식대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제3호Biomechanical analysis of distalization of mandibular molars by placing a mini-plate: A finite element study나영현, 박명순, 박민봉, 안장훈대한치과교정학회 · 대한치과교정학회지2017 · 제47권 제5호

이 간행물의 다른 논문 (5건)