본문 바로가기
KERD
논문KCI 등재

Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: The aims of this study were to investigate mandibular deformation under clenching and to estimate its effect on the stability of orthodontic mini-implants (OMI). Methods: Three finite element models were constructed using computed tomography (CT) images of 3 adults with different mandibular plane angles (A, low; B, average; and C, high). An OMI was placed between #45 and #46 in each model. Mandibular deformation under premolar and molar clenching was simulated. Comparisons were made between peri-orthodontic mini-implant compressive strain (POMI-CSTN) under clenching and orthodontic traction forces (150 g and 200 g). Results: Three models with different mandibular plane angles demonstrated different functional deformation characteristics. The compressive strains around the OMI were distributed mesiodistally rather than occlusogingivally. In model A, the maximum POMI-CSTN under clenching was observed at the mesial aspect of #46 (1,401.75 microstrain [μE]), and similar maximum POMI-CSTN was observed under a traction force of 150 g (1,415 μE). Conclusions: The maximum POMI-CSTN developed by clenching failed to exceed the normally allowed compressive cortical bone strains; however, additional orthodontic traction force to the OMI may increase POMI-CSTN to compromise OMI stability.

Abstract

Objective: The aims of this study were to investigate mandibular deformation under clenching and to estimate its effect on the stability of orthodontic mini-implants (OMI). Methods: Three finite element models were constructed using computed tomography (CT) images of 3 adults with different mandibular plane angles (A, low; B, average; and C, high). An OMI was placed between #45 and #46 in each model. Mandibular deformation under premolar and molar clenching was simulated. Comparisons were made between peri-orthodontic mini-implant compressive strain (POMI-CSTN) under clenching and orthodontic traction forces (150 g and 200 g). Results: Three models with different mandibular plane angles demonstrated different functional deformation characteristics. The compressive strains around the OMI were distributed mesiodistally rather than occlusogingivally. In model A, the maximum POMI-CSTN under clenching was observed at the mesial aspect of #46 (1,401.75 microstrain [μE]), and similar maximum POMI-CSTN was observed under a traction force of 150 g (1,415 μE). Conclusions: The maximum POMI-CSTN developed by clenching failed to exceed the normally allowed compressive cortical bone strains; however, additional orthodontic traction force to the OMI may increase POMI-CSTN to compromise OMI stability.

참고문헌 (26)

  1. Creekmore TD, "The possibility of skeletal anchorage", J Clin Orthod, 17, pp.266~269 (1983)
  2. Kanomi R, "Mini-implant for orthodontic anchorage", J Clin Orthod, 31, pp.763~767 (1997)
  3. Kuroda S, "Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort", Am J Orthod Dentofacial Orthop, 131, pp.9~15 (2007)
  4. Miyawaki S, "Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 124, pp.373~378 (2003)
  5. Chen Y, "Critical factors for the success of orthodontic mini-implants: a systematic review", Am J Orthod Dentofacial Orthop, 135, pp.284~291 (2009)
  6. Cheng SJ, "A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage", Int J Oral Maxillofac Implants, 19, pp.100~106 (2004)
  7. Korioth TW, "Deformation of the human mandible during simulated tooth clenching", J Dent Res, 73, pp.56~66 (1994)
  8. 모성서, "폐쇄성 수면무호흡 환자의 상기도 형태의 특징과 압력강하에 관한 3차원 전산유체역학해석", 대한치과교정학회지, 40(2), pp.66~76 (2010), 대한치과교정학회
  9. Sung SJ, "Effective enmasse retraction design with orthodontic miniimplant anchorage: a finite element analysis", Am J Orthod Dentofacial Orthop, 137, pp.648~657 (2010)
  10. Bonnet AS, "Biomechanical study of mandible bone supporting a four-implant retained bridge: finite element analysis of the influence of bone anisotropy and foodstuff position", Med Eng Phys, 31, pp.806~815 (2009)
  11. Gray H, "Anatomy of the human body. 30th ed" (1985), Lea & Febiger
  12. Gilroy AM, "Atlas of Anatomy" (2008), Thieme
  13. Hylander WL, "The functional significance of primate mandibular form", J Morphol, 160, pp.223~240 (1979)
  14. O’Mahony AM, "Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading", Clin Oral Implants Res, 12, pp.648~657 (2001)
  15. Tsunori M, "Relationship between facial types and tooth and bone characteristics of the mandible obtained by CT scanning", Angle Orthod, 68, pp.557~562 (1998)
  16. Sato H, "Relationship between masticatory function and internal structure of the mandible based on computed tomography findings", Am J Orthod Dentofacial Orthop, 128, pp.766~773 (2005)
  17. Masumoto T, "Relationships among facial type, buccolingual molar inclination, and cortical bone thickness of the mandible", Eur J Orthod, 23, pp.15~23 (2001)
  18. Moon CH, "Relationship between vertical skeletal pattern and success rate of orthodontic mini-implants", Am J Orthod Dentofacial Orthop, 138, pp.51~57 (2010)
  19. Proffit WR, "Occlusal forces in normal- and long-face adults", J Dent Res, 62, pp.566~570 (1983)
  20. Braun S, "A study of bite force, part 2: Relationship to various cephalometric measurements", Angle Orthod, 65, pp.373~377 (1995)
  21. van Spronsen PH, "Long-face craniofacial morphology: Cause or effect of weak masticatory musculature?", Semin Orthod, 16, pp.99~117 (2010)
  22. Frost HM, "Suggested fundamental concepts in skeletal physiology", Calcif Tissue Int, 52, pp.1~4 (1993)
  23. Frost HM, "Transient-steady state phenomena in microdamage physiology: a proposed algorithm for lamellar bone", Calcif Tissue Int, 44, pp.367~381 (1989)
  24. Frost HM, "Wolff ’s Law and bone’s structural adaptations to mechanical usage: an overview for clinicians", Angle Orthod, 64, pp.175~188 (1994)
  25. 김광덕, "교정용 마이크로 임플란트의 나사산 디자인 최적화", 대한치과교정학회지, 41(1), pp.25~35 (2011), 대한치과교정학회
  26. Wawrzinek C, "Microdamage in cortical bone due to the overtightening of orthodontic microscrews", J Orofac Orthop, 69, pp.121~134 (2008)

관련 논문AI추천

Effect of bite force on orthodontic mini-implants in the molar region: Finite element analysis김민지, 전윤식, Hyeon-Jung Lee, Kyung-Sook Lee대한치과교정학회 · 대한치과교정학회지2013 · 제43권 제5호Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length김성훈, 정규림, Bohm Choi, Dong-Ok Lee, Gerald Nelson, Ki-Ho Park, Seong Ho Han, Sung-Seo Mo대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제6호A three-dimensional finite element analysis of the relationship between masticatory performance and skeletal malocclusion박정철, 박종태, 신현승, 차정열대한치주과학회 · Journal of Periodontal & Implant Science2015 · 제45권 제1호Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles이기준, 황충주, Sang-Jin Sung, Seong-Jin Kim, Sung-Hwan Choi, Youn-Sic Chun대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제4호Effects of the Angulation of Orthodontic Mini-Implant as an Indirect Anchorage : A Three-Dimensional Finite Element Analysis김민지, 박선형, 박영진, 전윤식대한턱관절교합학회 · 구강회복응용과학지2011 · 제27권 제3호Biomechanical analysis of distalization of mandibular molars by placing a mini-plate: A finite element study나영현, 박명순, 박민봉, 안장훈대한치과교정학회 · 대한치과교정학회지2017 · 제47권 제5호

이 간행물의 다른 논문 (7건)