Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone loss
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective: To develop a method for generating three-dimensional (3D) digital models of the periodontal ligament (PDL) using 3D cone-beam computed tomography (CBCT) reconstruction and to evaluate the accuracy and agreement of the 3D PDL models in the measurement of periodontal bone loss. Methods: CBCT data collected from four patients with skeletal Class III malocclusion prior to periodontal surgery were reconstructed at three voxel sizes (0.2 mm, 0.25 mm, and 0.3 mm), and 3D tooth and alveolar bone models were generated to obtain digital PDL models for the maxillary and mandibular anterior teeth. Linear measurements of the alveolar bone crest obtained during periodontal surgery were compared with the digital measurements for assessment of the accuracy of the digital models. The agreement and reliability of the digital PDL models were analyzed using intra- and interexaminer correlation coefficients and Bland–Altman plots. Results: Digital models of the maxillary and mandibular anterior teeth, PDL, and alveolar bone of the four patients were successfully established. Relative to the intraoperative measurements, linear measurements obtained from the 3D digital models were accurate, and there were no significant differences among different voxel sizes at different sites. High diagnostic coincidence rates were found for the maxillary anterior teeth. The digital models showed high intra- and interexaminer agreement. Conclusions: Digital PDL models generated by 3D CBCT reconstruction can provide accurate and useful information regarding the alveolar crest morphology and facilitate reproducible measurements. This could assist clinicians in the evaluation of periodontal prognosis and establishment of an appropriate orthodontic treatment plan.
Abstract
Objective: To develop a method for generating three-dimensional (3D) digital models of the periodontal ligament (PDL) using 3D cone-beam computed tomography (CBCT) reconstruction and to evaluate the accuracy and agreement of the 3D PDL models in the measurement of periodontal bone loss. Methods: CBCT data collected from four patients with skeletal Class III malocclusion prior to periodontal surgery were reconstructed at three voxel sizes (0.2 mm, 0.25 mm, and 0.3 mm), and 3D tooth and alveolar bone models were generated to obtain digital PDL models for the maxillary and mandibular anterior teeth. Linear measurements of the alveolar bone crest obtained during periodontal surgery were compared with the digital measurements for assessment of the accuracy of the digital models. The agreement and reliability of the digital PDL models were analyzed using intra- and interexaminer correlation coefficients and Bland–Altman plots. Results: Digital models of the maxillary and mandibular anterior teeth, PDL, and alveolar bone of the four patients were successfully established. Relative to the intraoperative measurements, linear measurements obtained from the 3D digital models were accurate, and there were no significant differences among different voxel sizes at different sites. High diagnostic coincidence rates were found for the maxillary anterior teeth. The digital models showed high intra- and interexaminer agreement. Conclusions: Digital PDL models generated by 3D CBCT reconstruction can provide accurate and useful information regarding the alveolar crest morphology and facilitate reproducible measurements. This could assist clinicians in the evaluation of periodontal prognosis and establishment of an appropriate orthodontic treatment plan.
참고문헌 (44)
- Beertsen W, "The periodontal ligament: a unique, multifunctional connective tissue", Periodontol 2000, 13, pp.20~40 (1997)
- de Jong T, "The intricate anatomy of the periodontal ligament and its development : lessons for periodontal regeneration", J Periodontal Res, 52, pp.965~974 (2017)
- Jiang N, "Periodontal ligament and alveolar bone in health and adaptation : tooth movement", Front Oral Biol, 18, pp.1~8 (2016)
- Proffit WR, "Contemporary orthodontics" (2018), Elsevier
- 박사범, "Three-dimensional measurement of periodontal surface area for quantifying inflammatory burden", Journal of Periodontal & Implant Science, 47(3), pp.154~164 (2017), 대한치주과학회
- 이상희, "Assessment of lower incisor alveolar bone width using cone-beam computed tomography images in skeletal Class III adults of different vertical patterns", 대한치과교정학회지, 48(6), pp.349~356 (2018), 대한치과교정학회
- Kook YA, "Comparison of alveolar bone loss around incisors in normal occlusion samples and surgical skeletal class III patients", Angle Orthod, 82, pp.645~652 (2012)
- Fleiner J, "Digital method for quantification of circumferential periodontal bone level using cone beam CT", Clin Oral Investig, 17, pp.389~396 (2013)
- Hong HH, "Incompatible amount of 3-D and 2-D periodontal attachments on micro-CT scanned premolars", PLoS One, 13, pp.e0209206~ (2018)
- Hong HH, "Decreased amount of supporting alveolar bone at single-rooted premolars is under estimated by 2D examinations", Sci Rep, 8, pp.45774~ (2017)
- Klock KS, "Periodontal attachment loss assessed by linear and area measurements in vitro", J Clin Periodontol, 20, pp.443~447 (1993)
- Gu Y, "Measurement of root surface area of permanent teeth with root variations in a Chinese population-a micro-CT analysis", Arch Oral Biol, 63, pp.75~81 (2016)
- Al-Rawi B, "Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans", J Oral Rehabil, 37, pp.352~358 (2010)
- Wang Y, "Accuracy of volumetric measurement of simulated root resorption lacunas based on cone beam computed tomography", Orthod Craniofac Res, 16, pp.169~176 (2013)
- Jintana Tasanapanont, "Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography", Imaging Science in Dentistry, 47(2), pp.117~122 (2017), 대한영상치의학회
- Palkovics D, "Digital three-dimensional visualization of intrabony periodontal defects for regenerative surgical treatment planning", BMC Oral Health, 20, pp.351~ (2020)
- Tayman MA, "Comparison of linear and volumetric measurements obtained from periodontal defects by using cone beam-CT and micro-CT : an in vitro study", Clin Oral Investig, 23, pp.2235~2244 (2019)
- Mito T, "Cervical vertebral bone age in girls", Am J Orthod Dentofacial Orthop, 122, pp.380~385 (2002)
- Vasir NS, "Dental and skeletal changes following sagittal split osteotomy for correction of mandibular prognathism", Eur J Orthod, 13, pp.134~142 (1991)
- Forst D, "Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols", Prog Orthod, 15, pp.69~ (2014)
- Jing WD, "Periodontal soft-and hard-tissue changes after augmented corticotomy in Chinese adult patients with skeletal Angle Class III malocclusion : a nonrandomized controlled trial", J Periodontol, 91, pp.1419~1428 (2020)
- Scarfe WC, "The emerging role of maxillofacial radiology in the diagnosis and management of patients with complex periodontitis", Periodontol 2000, 74, pp.116~139 (2017)
- Kim DM, "When is cone-beam computed tomography imaging appropriate for diagnostic inquiry in the management of inflammatory periodontitis? An American Academy of Periodontology best evidence review", J Periodontol, 88, pp.978~998 (2017)
- Isabela Goulart Gil Choi, "Comparison of conventional imaging techniques and CBCT for periodontal evaluation: A systematic review", Imaging Science in Dentistry, 48(2), pp.79~86 (2018), 대한영상치의학회
- Spin-Neto R, "Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry : a systematic review", J Digit Imaging, 26, pp.813~820 (2013)
- Maret D, "Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT", Dentomaxillofac Radiol, 41, pp.649~655 (2012)
- Dong T, "Detection of alveolar bone defects with three different voxel sizes of cone-beam computed tomography : an in vitro study", Sci Rep, 9, pp.8146~ (2019)
- Sang YH, "Accuracy assessment of three-dimensional surface reconstructions of in vivo teeth from conebeam computed tomography", Chin Med J(Engl), 129, pp.1464~1470 (2016)
- Patcas R, "Accuracy of cone-beam computed tomography at different resolutions assessed on the bony covering of the mandibular anterior teeth", Am J Orthod Dentofacial Orthop, 141, pp.41~50 (2012)
- Sun Z, "Effect of bone thickness on alveolar bone-height measurements from cone-beam computed tomography images", Am J Orthod Dentofacial Orthop, 139, pp.e117~e127 (2011)
- Wood R, "Factors affecting the accuracy of buccal alveolar bone height measurements from cone-beam computed tomography images", Am J Orthod Dentofacial Orthop, 143, pp.353~363 (2013)
- de-Azevedo-Vaz SL, "Detection of periimplant fenestration and dehiscence with the use of two scan modes and the smallest voxel sizes of a cone-beam computed tomography device", Oral Surg Oral Med Oral Pathol Oral Radiol, 115, pp.121~127 (2013)
- Icen M, "Comparison of CBCT with different voxel sizes and intraoral scanner for detection of periodontal defects : an in vitro study", Dentomaxillofac Radiol, 49, pp.20190197~ (2020)
- Pauwels R, "Effect of exposure parameters and voxel size on bone structure analysis in CBCT", Dentomaxillofac Radiol, 44, pp.20150078~ (2015)
- Harris BT, "Creation of a 3-dimensional virtual dental patient for computer-guided surgery and CAD-CAM interim complete removable and fixed dental prostheses : a clinical report", J Prosthet Dent, 117, pp.197~204 (2017)
- Lim Seung-Weon, "Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root", 대한치과교정학회지, 50(4), pp.229~237 (2020), 대한치과교정학회[DOI]
- Lee RJ, "Three-dimensional monitoring of root movement during orthodontic treatment", Am J Orthod Dentofacial Orthop, 147, pp.132~142 (2015)
- Lee RJ, "Monitoring of typodont root movement via crown superimposition of single cone-beam computed tomography and consecutive intraoral scans", Am J Orthod Dentofacial Orthop, 145, pp.399~409 (2014)
- Wang T, "Evaluation of tooth root surface area using a threedimensional scanning technique and cone beam computed tomographic reconstruction in vitro", Arch Oral Biol, 84, pp.13~18 (2017)
- Kuralt M, "The precision of gingival recession measurements is increased by an automated curvature analysis method", BMC Oral Health, 21, pp.505~ (2021)
- Pini-Prato G, "Classification of dental surface defects in areas of gingival recession", J Periodontol, 81, pp.885~890 (2010)
- Maret D, "Comparison of the accuracy of 3-dimensional cone-beam computed tomography and micro-computed tomography reconstructions by using different voxel sizes", J Endod, 40, pp.1321~1326 (2014)
- Gu Y, "Measurement of root surface area of permanent teeth in a Chinese population", Arch Oral Biol, 81, pp.26~30 (2017)
- Damstra J, "Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes", Am J Orthod Dentofacial Orthop, 137, pp.16~ (2010)
