본문 바로가기
KERD
논문KCI 등재

Effects of reversing the coiling direction on the force-deflection characteristics of nickel-titanium closed-coil springs

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: To investigate the effects of reversing the coiling direction of nickeltitanium closed-coil springs (NiTi-CCSs) on the force-deflection characteristics. Methods: The samples consisted of two commercially available conventional NiTi-CCS groups and two reverse-wound NiTi-CCS groups (Ormco-Conventional vs. Ormco-Reverse; GAC-Conventional vs. GAC-Reverse; n = 20 per group). The reverse-wound NiTi-CCSs were directly made from the corresponding conventional NiTi-CCSs by reversing the coiling direction. Tensile tests were performed for each group in a temperature-controlled acrylic chamber (37 ± 1oC). After measuring the force level, the range of the deactivation force plateau (DFP) and the amount of mechanical hysteresis (MH), statistical analyses were performed. Results: The Ormco-Reverse group exhibited a significant shift of the DFP end point toward the origin point (2.3 to 0.6 mm), an increase in the force level (1.2 to 1.3 N) and amount of MH (1.0 to 1.5 N) compared to the Ormco-Conventional group (all p < 0.001), which indicated that force could be constantly maintained until the end of the deactivation curve. In contrast, the GAC-Reverse group exhibited a significant shift of the DFP-end point away from the origin point (0.2 to 3.3 mm), a decrease in the force level (1.1 to 0.9 N) and amount of MH (0.6 to 0.4 N) compared to the GAC-Conventional group (all p < 0.001), which may hinder the maintenance of force until the end of the deactivation curve. Conclusions: The two commercially available NiTi-CCS groups exhibited different patterns of change in the force-deflection characteristics when the coiling direction was reversed.

Abstract

Objective: To investigate the effects of reversing the coiling direction of nickeltitanium closed-coil springs (NiTi-CCSs) on the force-deflection characteristics. Methods: The samples consisted of two commercially available conventional NiTi-CCS groups and two reverse-wound NiTi-CCS groups (Ormco-Conventional vs. Ormco-Reverse; GAC-Conventional vs. GAC-Reverse; n = 20 per group). The reverse-wound NiTi-CCSs were directly made from the corresponding conventional NiTi-CCSs by reversing the coiling direction. Tensile tests were performed for each group in a temperature-controlled acrylic chamber (37 ± 1oC). After measuring the force level, the range of the deactivation force plateau (DFP) and the amount of mechanical hysteresis (MH), statistical analyses were performed. Results: The Ormco-Reverse group exhibited a significant shift of the DFP end point toward the origin point (2.3 to 0.6 mm), an increase in the force level (1.2 to 1.3 N) and amount of MH (1.0 to 1.5 N) compared to the Ormco-Conventional group (all p < 0.001), which indicated that force could be constantly maintained until the end of the deactivation curve. In contrast, the GAC-Reverse group exhibited a significant shift of the DFP-end point away from the origin point (0.2 to 3.3 mm), a decrease in the force level (1.1 to 0.9 N) and amount of MH (0.6 to 0.4 N) compared to the GAC-Conventional group (all p < 0.001), which may hinder the maintenance of force until the end of the deactivation curve. Conclusions: The two commercially available NiTi-CCS groups exhibited different patterns of change in the force-deflection characteristics when the coiling direction was reversed.

참고문헌 (20)

  1. Wichelhaus A, "Mechanical behavior and clinical application of nickeltitanium closed-coil springs under different stress levels and mechanical loading cycles", Am J Orthod Dentofacial Orthop, 137, pp.671~678 (2010)
  2. Bezrouk A, "Thermomechanical properties of nickel-titanium closed-coil springs and their implications for clinical practice", Am J Orthod Dentofacial Orthop, 146, pp.319~327 (2014)
  3. Burstone CJ, "Chinese NiTi wire--a new orthodontic alloy", Am J Orthod, 87, pp.445~452 (1985)
  4. Miura F, "The superelastic property of the Japanese NiTi alloy wire for use in orthodontics", Am J Orthod Dentofacial Orthop, 90, pp.1~10 (1986)
  5. Miura F, "The superelastic Japanese NiTi alloy wire for use in orthodontics. Part III. Studies on the Japanese NiTi alloy coil springs", Am J Orthod Dentofacial Orthop, 94, pp.89~96 (1988)
  6. Maganzini AL, "Forces of various nickel titanium closed coil springs", Angle Orthod, 80, pp.182~187 (2010)
  7. Manhartsberger C, "Force delivery of Ni-Ti coil springs", Am J Orthod Dentofacial Orthop, 109, pp.8~21 (1996)
  8. Ravipati RR, "An adjustment in NiTi closed coil spring for an extended range of activation", Int J Orthod Milwaukee, 25, pp.21~22 (2014)
  9. Vidoni G, "Combined aging effects of strain and thermocycling on unload deflection modes of nickel-titanium closed-coil springs : an in-vitro comparative study", Am J Orthod Dentofacial Orthop, 138, pp.451~457 (2010)
  10. Alavi S, "The effects of aging process and preactivation on mechanical properties of nickeltitanium closed coil springs", Dent Res J(Isfahan), 12, pp.231~234 (2015)
  11. Segner D, "Properties of superelastic wires and their relevance to orthodontic treatment", Eur J Orthod, 17, pp.395~402 (1995)
  12. Bartzela TN, "Load-deflection characteristics of superelastic nickel-titanium wires", Angle Orthod, 77, pp.991~998 (2007)
  13. Jee KK, "Method to provide initial tension for coil spring and its application. United States Patent US 8,186,060", ~ (2012)
  14. Jee KK, "Improvement of actuating properties of a SMA coil spring by change in coil orientation", Mater Sci Forum, 738-739, pp.589~594 (2013)
  15. Santoro M, "Pseudoelasticity and thermoelasticity of nickel-titanium alloys:a clinically oriented review. Part I: temperature transitional ranges", Am J Orthod Dentofacial Orthop, 119, pp.587~593 (2001)
  16. Vieira CI, "Superelasticity and force plateau of nickel-titanium springs : an in vitro study", Dental Press J Orthod, 21, pp.46~55 (2016)
  17. Martins RP, "Group A T-loop for differential moment mechanics : an implant study", Am J Orthod Dentofacial Orthop, 135, pp.182~189 (2009)
  18. von Fraunhofer JA, "Force generation by orthodontic coil springs", Angle Orthod, 63, pp.145~148 (1993)
  19. Tripolt H, "Force characteristics of nickel-titanium tension coil springs", Am J Orthod Dentofacial Orthop, 115, pp.498~507 (1999)
  20. Vieira CIV, "Deformation of nickel-titanium closed coil springs : an in vitro study", Dental Press J Orthod, 22, pp.38~46 (2017)

관련 논문AI추천

수종의 니켈-티타늄 폐쇄형 코일 스프링의 하중-변위 특성 및 소성 변형 비교손아영, 임성훈대한치과교정학회 · 대한치과교정학회지2009 · 제39권 제5호Thermo-mechanical properties in bending of a multizone nickel-titanium archwire: A retrieval analysisChristoph Bourauel, Iosif Sifakakis, Ioulia-Maria Mylonopoulou, Panagiotis Roulias, Theodore Eliades대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제2호Effect of activation and preactivation on the mechanical behavior and neutral position of stainless steel and beta-titanium T-loopsAfonso Pinhão Ferreira, Ana Cristina Braga, Maria Cristina Pollmann, Rui Moreira, Saúl Matos de Castro대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제4호Comparison of transition temperature range and phase transformation behavior of nickel-titanium wires백승학, 임범순, Cheol-We Kim, Yong-Keun Lee, Yu-Hyun Lee대한치과교정학회 · 대한치과교정학회지2010 · 제40권 제1호Effects of prestretch on stress relaxation and permanent deformation of orthodontic synthetic elastomeric chains김경호, 김광만, 유형석, 장지혜, 차정열, 황충주대한치과교정학회 · 대한치과교정학회지2018 · 제48권 제6호Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets김윤미, 유형석, 차정열, 황충주, Seon Gun Tahk대한치과교정학회 · 대한치과교정학회지2014 · 제44권 제4호

이 간행물의 다른 논문 (7건)