Objective: This study aimed to compare the mechanical and thermal properties in the anterior and posterior segments of new and retrieved specimens of a commercially available multizone superelastic nickel-titanium (NiTi) archwire. Methods: The following groups of 0.016 × 0.022-inch Bioforce NiTi archwires were compared: a) anterior and b) posterior segments of new specimens and c) anterior and d) posterior segments of retrieved specimens. Six specimens were evaluated in each group, by three-point bending and bend and free recovery tests. Bending moduli (Eb) were calculated. Furthermore, the new specimens were evaluated with scanning electron microscopy/energy-dispersive X-ray spectrometry. A multiple linear regression model with a random intercept at the wire level was applied for data analysis. Results: The forces in the posterior segments or new specimens were higher than those recorded in the anterior segments or retrieved specimens, respectively. Accordingly, Eb also varied. Higher austenite start and austenite finish (Af) temperatures were recorded in the anterior segments. No statistically significant differences were found for these temperatures between retrieved and new wires. The mean elemental composition was (weight percentage): Ni, 52.6 ± 0.5; Ti, 47.4 ± 0.5. Conclusions: The existence of multiple force zones was confirmed in new and retrieved Bioforce archwires. The retrieved archwires demonstrated lower forces during the initial stages of deactivation in three-point bending tests, compared with new specimens. The Af temperature of these archwires may lie higher than the regular intraoral temperature. Even at 2 mm deflections, the forces recorded from these archwires may lie beyond biologically safe limits.

Abstract

Objective: This study aimed to compare the mechanical and thermal properties in the anterior and posterior segments of new and retrieved specimens of a commercially available multizone superelastic nickel-titanium (NiTi) archwire. Methods: The following groups of 0.016 × 0.022-inch Bioforce NiTi archwires were compared: a) anterior and b) posterior segments of new specimens and c) anterior and d) posterior segments of retrieved specimens. Six specimens were evaluated in each group, by three-point bending and bend and free recovery tests. Bending moduli (Eb) were calculated. Furthermore, the new specimens were evaluated with scanning electron microscopy/energy-dispersive X-ray spectrometry. A multiple linear regression model with a random intercept at the wire level was applied for data analysis. Results: The forces in the posterior segments or new specimens were higher than those recorded in the anterior segments or retrieved specimens, respectively. Accordingly, Eb also varied. Higher austenite start and austenite finish (Af) temperatures were recorded in the anterior segments. No statistically significant differences were found for these temperatures between retrieved and new wires. The mean elemental composition was (weight percentage): Ni, 52.6 ± 0.5; Ti, 47.4 ± 0.5. Conclusions: The existence of multiple force zones was confirmed in new and retrieved Bioforce archwires. The retrieved archwires demonstrated lower forces during the initial stages of deactivation in three-point bending tests, compared with new specimens. The Af temperature of these archwires may lie higher than the regular intraoral temperature. Even at 2 mm deflections, the forces recorded from these archwires may lie beyond biologically safe limits.

참고문헌 (51)

  1. Miura F, "The superelastic property of the Japanese NiTi alloy wire for use in orthodontics", Am J Orthod Dentofacial Orthop, 90, pp.1~10 (1986)
  2. Bradley TG, "Differential scanning calorimetry(DSC)analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires", Am J Orthod Dentofacial Orthop, 109, pp.589~597 (1996)
  3. Aghili H, "Load deflection characteristics of nickel titanium initial archwires", J Dent(Tehran), 12, pp.695~704 (2015)
  4. Khier SE, "Bending properties of superelastic and nonsuperelastic nickel-titanium orthodontic wires", Am J Orthod Dentofacial Orthop, 99, pp.310~318 (1991)
  5. Andreasen G, "A review of superelastic and thermodynamic nitinol wire", Quintessence Int, 16, pp.623~626 (1985)
  6. Kusy RP, "A review of contemporary archwires : their properties and characteristics", Angle Orthod, 67, pp.197~207 (1997)
  7. Kusy RP, "Thermal and mechanical characteristics of stainless steel, titanium-molybdenum, and nickel-titanium archwires", Am J Orthod Dentofacial Orthop, 131, pp.229~237 (2007)
  8. Barwart O, "An evaluation of the transition temperature range of super-elastic orthodontic NiTi springs using differential scanning calorimetry", Eur J Orthod, 21, pp.497~502 (1999)
  9. Brantley WA, "Orthodontic materials: scientific and clinical aspects" (2001), Goerge Thieme Verlag
  10. Duerig TW, "Engineering aspects of shape memory alloys", pp.13~20 (1990), Butterworth-Heinemann
  11. Meling TR, "The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bending", Am J Orthod Dentofacial Orthop, 119, pp.263~273 (2001)
  12. Bartzela TN, "Load-deflection characteristics of superelastic nickel-titanium wires", Angle Orthod, 77, pp.991~998 (2007)
  13. Lombardo L, "The effect of temperature on the mechanical behavior of nickel-titanium orthodontic initial archwires", Angle Orthod, 83, pp.298~305 (2013)
  14. Nakano H, "Mechanical properties of several nickel-titanium alloy wires in three-point bending tests", Am J Orthod Dentofacial Orthop, 115, pp.390~395 (1999)
  15. Sakima MT, "How does temperature influence the properties of rectangular nickeltitanium wires?", Eur J Orthod, 28, pp.282~291 (2006)
  16. Mirabella AD, "Risk factors for apical root resorption of maxillary anterior teeth in adult orthodontic patients", Am J Orthod Dentofacial Orthop, 108, pp.48~55 (1995)
  17. Cannon JL, "Dual-flex archwires", J Clin Orthod, 18, pp.648~649 (1984)
  18. Thompson WJ, "Combination anchorage technique : an update of current mechanics", Am J Orthod Dentofacial Orthop, 93, pp.363~379 (1988)
  19. Sanders E, "Comparison of multiforce nickel-titanium wires to multistrand wires without force zones in bending and torque measurements", J Orofac Orthop, 83, pp.382~394 (2022)
  20. Lombardo L, "Mechanical properties of multi-force vs. conventional NiTi archwires", J Orofac Orthop, 80, pp.57~67 (2019)
  21. ASTM International, "ASTM F2082", F2082M-16. Standard test method for determination of transformation temperature of nickel-titanium shape memory alloys by bend and free recovery, 2016
  22. ASTM International, "ASTM F2004-17. Standard test method for transformation temperature of nickeltitanium alloys by thermal analysis", ASTM, ~ (2017)
  23. Nespoli A, "Non-conventional techniques for the study of phase transitions in NiTi-based alloys", J Mater Eng Perform, 23, pp.2491~2497 (2014)
  24. Silness J, "Periodontal disease in pregnancy. II. Correlation between oral hygiene and periodontal condtion", Acta Odontol Scand, 22, pp.121~135 (1964)
  25. Bourauel C, "An experimental apparatus for the simulation of three-dimensional movements in orthodontics", J Biomed Eng, 14, pp.371~378 (1992)
  26. DIN Dentistry, "Wires for use in orthodontics (ISO 15841:2014", Amd 1:2020), 2020
  27. ASTM International, "ASTM F2082-06. Standard test method for determination of transformation temperature of nickel-titanium shape memory alloys by bend and free recovery", ASTM, ~ (2016)
  28. Sifakakis I, "Laboratory evaluation of orthodontic biomechanics : the clinical applications revisited", Semin Orthod, 23, pp.382~389 (2017)
  29. Krishnan V, "Mechanical properties and surface characteristics of three archwire alloys", Angle Orthod, 74, pp.825~831 (2004)
  30. Pelton AR, "Fatigue testing of diamond-shaped specimens", International Conference on Shape Memory and Superelastic Technologies, SMST-2003 (2004)
  31. Theodorou CI, "Optimal force magnitude for bodily orthodontic tooth movement with fixed appliances : a systematic review", Am J Orthod Dentofacial Orthop, 156, pp.582~592 (2019)
  32. Proffit W, "Contemporary orthodontics", pp.278~ (2018), Elsevier Mosby
  33. Sifakakis I, "A comparative assessment of the forces and moments generated at the maxillary incisors between conventional and self-ligating brackets using a reverse curve of Spee NiTi archwire", Aust Orthod J, 26, pp.127~133 (2010)
  34. Ibe DM, "Superelastic materials displaying different force levels within one archwire", J Orofac Orthop, 59, pp.29~38 (1998)
  35. Elayyan F, "Ex vivo surface and mechanical properties of coated orthodontic archwires", Eur J Orthod, 30, pp.661~667 (2008)
  36. Bradley TG, "Reduction of mechanical properties of NiTi wires due to clinical use", J Dent Res, 82(special issue A) (2003)
  37. Obaisi NA, "Comparison of the transformation temperatures of heat-activated Nickel-Titanium orthodontic archwires by two different techniques", Dent Mater, 32, pp.879~888 (2016)
  38. Mehta ASK, "Thermomechanical characterization of variable force NiTi orthodontic archwires", Master's, pp.2015
  39. Chen JT, "An apparatus to measure the shape memory properties of Nitinol tubes for medical applications", J Phys IV, 5(C8), pp.1247~1252 (1995)
  40. Butler J, "Probing martensitic transition in Nitinol wire: a comparison of X‐ray diffraction and other techniques", International Conference on Advances in Materials and Processing Technologies. AIP Conference Proceedings (2010), American Institute of Physics
  41. Norwich DW, "A Study of the properties of a high temperature binary Nitinol alloy above and below its martensite to austenite transformation temperature" (2010), SAES Memry Corporation
  42. Pelton AR, "Optimisation of processing and properties of medical grade Nitinol wire", Minim Invasive Ther Allied Technol, 9, pp.107~118 (2000)
  43. Longman CM, "Variations in tooth surface temperature in the oral cavity during fluid intake", Biomaterials, 8, pp.411~414 (1987)
  44. Otsuka K, "Engineering aspects of shape memory alloys", pp.36~45 (1990), Butterworth-Heinemann Ltd
  45. Biermann MC, "Thermal analysis of as-received and clinically retrieved copper-nickel-titanium orthodontic archwires", Angle Orthod, 77, pp.499~503 (2007)
  46. Fariborz Amin, "Variations in surface roughness of seven orthodontic archwires: an SEM-profi lometry study", 대한치과교정학회지, 42(3), pp.129~137 (2012), 대한치과교정학회[DOI]
  47. Usui T, "Mechanical and frictional properties of aesthetic orthodontic wires obtained by hard chrome carbide plating", J Dent Sci, 13, pp.151~159 (2018)
  48. Pelsue BM, "Structure, composition, and mechanical properties of Australian orthodontic wires", Angle Orthod, 79, pp.97~101 (2009)
  49. Brantley W, "Orthodontic materials" (2001), Thieme
  50. Thompson SA, "An overview of nickel-titanium alloys used in dentistry", Int Endod J, 33, pp.297~310 (2000)
  51. Kusy RP, "Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states", Angle Orthod, 63, pp.164~ (1993)

관련 논문AI추천

이 간행물의 다른 논문 (6건)