Effect of surface anodization on stability of orthodontic microimplant

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: To determine the effect of surface anodization on the interfacial strength between an orthodontic microimplant (MI) and the rabbit tibial bone, particularly in the initial phase aft er placement. Methods: A total of 36 MIs were driven into the tibias of 3 mature rabbits by using the self-drilling method and then removed aft er 6 weeks. Half the MIs were as-machined (n = 18; machined group), while the remaining had anodized surfaces (n = 18; anodized group). Th e peak insertion torque (PIT) and the peak removal torque (PRT) values were measured for the 2 groups of MIs. Th ese values were then used to calculate the interfacial shear strength between the MI and cortical bone. Results: Th ere were no statistical differences in terms of PIT between the 2 groups. However, mean PRT was signifi cantly greater for the anodized implants (3.79 ± 1.39 Ncm) than for the machined ones (2.05 ± 1.07 Ncm) (p < 0.01). The interfacial strengths, converted from PRT, were calculated at 10.6 MPa and 5.74 MPa for the anodized and machined group implants, respectively. Conclusions: Anodization of orthodontic MIs may enhance their early-phase retention capability, thereby ensuring a more reliable source of absolute anchorage.

Abstract

Objective: To determine the effect of surface anodization on the interfacial strength between an orthodontic microimplant (MI) and the rabbit tibial bone, particularly in the initial phase aft er placement. Methods: A total of 36 MIs were driven into the tibias of 3 mature rabbits by using the self-drilling method and then removed aft er 6 weeks. Half the MIs were as-machined (n = 18; machined group), while the remaining had anodized surfaces (n = 18; anodized group). Th e peak insertion torque (PIT) and the peak removal torque (PRT) values were measured for the 2 groups of MIs. Th ese values were then used to calculate the interfacial shear strength between the MI and cortical bone. Results: Th ere were no statistical differences in terms of PIT between the 2 groups. However, mean PRT was signifi cantly greater for the anodized implants (3.79 ± 1.39 Ncm) than for the machined ones (2.05 ± 1.07 Ncm) (p < 0.01). The interfacial strengths, converted from PRT, were calculated at 10.6 MPa and 5.74 MPa for the anodized and machined group implants, respectively. Conclusions: Anodization of orthodontic MIs may enhance their early-phase retention capability, thereby ensuring a more reliable source of absolute anchorage.

참고문헌 (33)

  1. Park HS, "Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion", J Clin Orthod, 35, pp.417~422 (2001)
  2. Bae SM, "Clinical application of micro-implant anchorage", J Clin Orthod, 36, pp.298~302 (2002)
  3. Kyung HM, "Develop ment of orthodontic micro-implants for intraoral anchorage", J Clin Orthod, 37, pp.321~328 (2003)
  4. Kuroda S, "Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort", Am J Orthod Dentofacial Orthop, 131, pp.9~15 (2007)
  5. Baek SH, "Success rate and risk factors associated with mini-implants reinstalled in the maxilla", Angle Orthod, 78, pp.895~901 (2008)
  6. Wu TY, "Factors associated with the stability of mini-implants for orthodontic anchorage: a study of 414 samples in Taiwan", J Oral Maxillofac Surg, 67, pp.1595~1599 (2009)
  7. Kim SH, "Rotational Resistance of Surface-Treated Mini-implants", ANGLE ORTHODONTIST, 79, pp.899~907, MOSBY-ELSEVIER
  8. 전미선, "분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구", 대한치과교정학회지, 38(5), pp.328~336 (2008), 대한치과교정학회
  9. Shibli JA, "Influence of implant surface topography on early osseointegration: a histolo gical study in human jaws", J Biomed Mater Res B Appl Biomater, 80, pp.377~385 (2007)
  10. Ivanoff CJ, "Histologic evaluation of bone response to oxidized and turned titanium micro-implants in human jawbone", Int J Oral Maxillofac Implants, 18, pp.341~348 (2003)
  11. Kieswetter K, "The role of implant surface characteristics in the healing of bone", Crit Rev Oral Biol Med, 7, pp.329~345 (1996)
  12. Cordioli G, "Removal torque and histomorphometric investigation of 4 different titanium surfaces: an experimental study in the rabbit tibia", Int J Oral Maxillofac Implants, 15, pp.668~674 (2000)
  13. Thomas KA, "The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials", J Biomed Mater Res, 21, pp.1395~1414 (1987)
  14. Li D, "Biomechanical comparison of the sandblasted and acid-etched and the machined and acidetched titanium surface for dental implants", J Biomed Mater Res, 60, pp.325~332 (2002)
  15. Cho SA, "A removal torque of the lasertreated titanium implants in rabbit tibia", Biomaterials, 24, pp.4859~4863 (2003)
  16. 설영택, "The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant", BIOMATERIALS, 24, pp.3893~3907, ELSEVIER SCI LTD
  17. Son WW, "In vivo histological response to anodized and anodized", hydrothermally treated titanium implants, 2003, pp.66, 520~525
  18. 설영택, "Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides", CLINICAL ORAL IMPLANTS RESEARCH, 13, pp.252~259 (2002), BLACKWELL PUBLISHING
  19. Jungner M, "Oxidized titanium implants (Nobel Biocare TiUnite) compared with turned titanium implants (Nobel Biocare mark III) with respect to implant failure in a group of consecutive patients treated with early functional loading and two-stage protocol", Clin Oral Implants Res, 16, pp.308~312 (2005)
  20. Suh JY, "Effect of hydrothermally treated anodic oxide films on osteoblast attachment and proliferation", Biomaterials, 24, pp.347~355 (2003)
  21. Roberts WE, "Osseous adaptation to continuous loa ding of rigid endosseous implants", Am J Orthod, 86, pp.95~111 (1984)
  22. Esposito M, "Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology", Eur J Oral Sci, 106, pp.527~551 (1998)
  23. Olmedo D, "Macrophages related to dental implant failure", Implant Dent, 12, pp.75~80 (2003)
  24. Sánchez-Gárces MA, "Periimplantitis", Med Oral Patol Oral Cir Bucal, 9(Suppl), pp.63~74 (2004)
  25. Zhu X, "Surface analysis of anodic oxide films containing phosphorus on titanium", Int J Oral Maxillofac Implants, 17, pp.331~336 (2002)
  26. Zhu X, "Surface characteristics and structure of anodic oxide fi lms containing Ca and P on a titanium implant material", J Biomed Mater Res, 60, pp.333~338 (2002)
  27. Larsson C, "Bone response to surface modified titanium implants - studies on the tissue response after 1 year to machined and electropolished implants with different oxide thicknesses", J Mater Sci Mater Med, 8, pp.721~729 (1997)
  28. Frost HM, "A 2003 update of bone physiology and Wolff ’s Law for clinicians", Angle Orthod, 74, pp.3~15 (2004)
  29. Motoyoshi M, "Recommended placement torque when tightening an orthodontic mini-implant", Clin Oral Implants Res, 17, pp.109~114 (2006)
  30. Kim JW, "Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage", Am J Orthod Dentofacial Orthop, 128, pp.190~194 (2005)
  31. 설영택, "Bone reactions to oxidized titanium implants with electrochemical anion sulphuric acid and phosphoric acid incorporation.", Clinical implant dentistry and related research, 4(2), pp.78~87 (2002), B.C. Decker Inc.
  32. 설영택, "Oxidized titanium screws coated with calcium ions and their performance in rabbit bone", INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 17, pp.625~634 (2002), QUINTESSENCE PUBLISHING CO INC
  33. Morais LS, "Titanium alloy mini-implants for orthodontic anchorage: immediate loa ding and metal ion release", Acta Biomater, 3, pp.331~339 (2007)

관련 논문AI추천

Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implantsHo-Young Kim, Sang-Cheol Kim대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제6호Enhanced compatibility and initial stability of Ti6Al4V alloy orthodontic miniscrews subjected to anodization, cyclic precalcification, and heat treatmentEun-Ju Oh, Jong-Gee Kim, Seung-Youp Lee, Tae-Sung Bae, Thuy-Duong T. Nguyen, Young-Mi Jeon대한치과교정학회 · 대한치과교정학회지2014 · 제44권 제5호Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits고정우, 김성훈, 양재호, 이재봉, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제2호Effect of rotation bump on removal torque of orthodontic mini-implants김영균, 김종완, 김태우, 이종호, 정종화, Odontuya Gansukh대한구강악안면외과학회 · 대한구강악안면외과학회지2013 · 제36권 제6호The comparison of torque values in two types of miniscrews placed in rabbits: tapered and cylindrical shapes - Preliminary study김경호, 유현미, 정주령, Dong-Sung Park, In-Sung Jang, Seung-Hyun Kyung대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제4호Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torqueDavid Blažević, Ervin Kamenar, Stjepan Špalj, Višnja Katić대한치과교정학회 · 대한치과교정학회지2014 · 제44권 제4호

이 간행물의 다른 논문 (6건)