Effect of rotation bump on removal torque of orthodontic mini-implants

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. Materials and Methods: This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirty-two mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits and were removed after two weeks and four weeks, respectively. The maximum insertion torque (MIT), maximum removal torque (MRT), torque ratio (TR) of MRT to MIT and removal angular momentum (RAM) were all measured at the time of removal. Results: There were no significant differences between the two groups in MIT and MRT at two weeks or four weeks. However, TR and RAM at four weeks in the RB group were significantly higher than in the control group (P<0.05). TR of the RB group was significantly increased at four weeks (P<0.05). In both groups, RAM at four weeks was significantly higher than at two weeks (P<0.05). Conclusion: These results suggest that RB of the mini-implant could provide resistance to the removal rotation, although it did not increase the MRT.

Abstract

Objectives: This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. Materials and Methods: This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirty-two mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits and were removed after two weeks and four weeks, respectively. The maximum insertion torque (MIT), maximum removal torque (MRT), torque ratio (TR) of MRT to MIT and removal angular momentum (RAM) were all measured at the time of removal. Results: There were no significant differences between the two groups in MIT and MRT at two weeks or four weeks. However, TR and RAM at four weeks in the RB group were significantly higher than in the control group (P<0.05). TR of the RB group was significantly increased at four weeks (P<0.05). In both groups, RAM at four weeks was significantly higher than at two weeks (P<0.05). Conclusion: These results suggest that RB of the mini-implant could provide resistance to the removal rotation, although it did not increase the MRT.

참고문헌 (17)

  1. Chen Y, "Mechanical properties of self-drilling orthodontic micro-implants with different diameters", Angle Orthod, 80, pp.821~827 (2010)
  2. Kim YK, "Effects of the taper shape, dual-thread, and length on the mechanical properties of mini-implants", Angle Orthod, 79, pp.908~914 (2009)
  3. Herrmann I, "Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures", Int J Oral Maxillofac Implants, 20, pp.220~230 (2005)
  4. Reynders R, "Mini-implants in orthodontics: a systematic review of the literature", Am J Orthod Dentofacial Orthop, 135, pp.564.e1~564.e19 (2009)
  5. Kim JW, "Comparison of stability between cylindrical and conical type mini-implants. Mechanical and histological properties", Angle Orthod, 78, pp.692~698 (2008)
  6. Kim TW, "Effects of microgrooves on the success rate and soft tissue adaptation of orthodontic minis crews", Angle Orthod, 78, pp.1057~1064 (2008)
  7. Kim JW, "Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage", Am J Orthod Dentofacial Orthop, 128, pp.190~194 (2005)
  8. Sullivan DY, "The reverse-torque test: a clinical report", Int J Oral Maxillofac Implants, 11, pp.179~185 (1996)
  9. Linkow LI, "The press-fit", tap-in, anti-rotational vent-plant cylinder implant, 1995, pp.21, 40~45
  10. Ueda M, "Relationship between insertion torque and removal torque analyzed in fresh temporal bone", Int J Oral Maxillofac Implants, 6, pp.442~447 (1991)
  11. Consolo U, "Histologic and biomechanical evaluation of the effects of implant insertion torque on peri-implant bone healing", J Craniofac Surg, 24, pp.860~865 (2013)
  12. 이수영, "A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables", The Journal of Advanced of Prosthodontics, 2(4), pp.148~153 (2010), 대한치과보철학회
  13. Kim SH, "Rotational resistance of surface-treated mini-implants", Angle Orthod, 79, pp.899~907 (2009)
  14. Costa A, "Miniscrews as orthodontic anchorage: a preliminary report", Int J Adult Orthodon Orthognath Surg, 13, pp.201~209 (1998)
  15. Kwon TK, "Evaluation of early bone response to fluoride-modified and anodically oxidized titanium implants through continuous removal torque analysis", Implant Dent, 21, pp.427~432 (2012)
  16. Ahn SJ, "Histomorphometric analysis and removal torque of small diameter implants with alternative surface treatments and different designs", J Oral Implantol, 36, pp.263~272 (2010)
  17. Oltramari-Navarro PV, "The impact of healing time before loading on orthodontic mini-implant stability: a histomorphometric study in minipigs", Arch Oral Biol, 58, pp.806~812 (2013)

관련 논문AI추천

이 간행물의 다른 논문 (8건)