Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: To determine the unique contribution of geometrical design characteristicsof orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. Methods: Total numberof 100 cylindrical orthodontic mini-implants was used. Geometricaldesign characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-implants (Ortho Easy®, Aarhus, and Dual TopTM) with diameters ranging from 1.4 to 2.0 mm and lengths of 6 and 8 mm were measured. Maximum insertion torque was recorded during manual insertion of mini-implants into bone samples. Cortical bone thickness was measured. Retrieved data were analyzed in a multiple regression model. Results: Significant predictors for higher maximum insertion torque included larger outer diameter of implant, higher lead angle of thread, and thicker cortical bone, and their unique contribution to maximum insertion torque was 12.3%, 10.7%, and 24.7%, respectively. Conclusions: The maximum insertion torque values are best controlled by choosing an implant diameter and lead angle according to the assessed thickness of cortical bone.

Abstract

Objective: To determine the unique contribution of geometrical design characteristicsof orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. Methods: Total numberof 100 cylindrical orthodontic mini-implants was used. Geometricaldesign characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-implants (Ortho Easy®, Aarhus, and Dual TopTM) with diameters ranging from 1.4 to 2.0 mm and lengths of 6 and 8 mm were measured. Maximum insertion torque was recorded during manual insertion of mini-implants into bone samples. Cortical bone thickness was measured. Retrieved data were analyzed in a multiple regression model. Results: Significant predictors for higher maximum insertion torque included larger outer diameter of implant, higher lead angle of thread, and thicker cortical bone, and their unique contribution to maximum insertion torque was 12.3%, 10.7%, and 24.7%, respectively. Conclusions: The maximum insertion torque values are best controlled by choosing an implant diameter and lead angle according to the assessed thickness of cortical bone.

참고문헌 (26)

  1. Kanomi R, "Mini-implant for orthodontic anchorage", J Clin Orthod, 31, pp.763~767 (1997)
  2. Motoyoshi M, "Clinical indices for orthodontic miniimplants", J Oral Sci, 53, pp.407~412 (2011)
  3. Tseng YC, "The application of mini-implants for orthodontic anchorage", Int J Oral Maxillofac Surg, 35, pp.704~707 (2006)
  4. Poggio PM, "“Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch", Angle Orthod, 76, pp.191~197 (2006)
  5. Cheng SJ, "A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage", Int J Oral Maxillofac Implants, 19, pp.100~106 (2004)
  6. Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
  7. Motoyoshi M, "Recommended placement torque when tightening an orthodontic mini-implant", Clin Oral Implants Res, 17, pp.109~114 (2006)
  8. Pithon MM, "In vitro evaluation of insertion and removal torques of orthodontic mini-implants", Int J Oral Maxillofac Surg, 40, pp.80~85 (2011)
  9. Wilmes B, "Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage", Int J Oral Maxillofac Surg, 40, pp.697~703 (2011)
  10. Lim SA, "Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length", Angle Orthodontist, 78(2), pp.234~240 (2008)
  11. Xu Z, "Histomorphometric and biomechanical analyses of the osseointegration of loaded orthodontic microscrews inserted at different cortical bone thickness sites", Oral Surg Oral Med Oral Pathol Oral Radiol (2012)[DOI]
  12. Pithon MM, "Primary stability of orthodontic mini-implants inserted into maxilla and mandible of swine", Oral Surg Oral Med Oral Pathol Oral Radiol, 113, pp.748~754 (2012)
  13. Studenmund AH, "Instructor's manual to accompany. Using econometrics, a practical guide" (1987), Little Brown
  14. Miyawaki S, "Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 124, pp.373~378 (2003)
  15. American Gear Manufacturers Association, "Gear nomenclature, definitions of terms with symbols: AGMA standard" (2005), American Gear Manufacturers Association
  16. Dalstra M, "Load transfer of miniscrews for orthodontic anchorage", Orthodontics, 1, pp.53~62 (2004)
  17. Wilmes B, "Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study", Eur J Orthod, 33, pp.396~401 (2011)
  18. Kondo S, "Thermological study of drilling bone tissue with a high-speed drill", Neurosurgery, 46, pp.1162~1168 (2000)
  19. Brisman DL, "The effect of speed, pressure, and time on bone temperature during the drilling of implant sites", Int J Oral Maxillofac Implants, 11, pp.35~37 (1996)
  20. Toews AR, "Effect of feed rate and drill speed on temperatures in equine cortical bone", Am J Vet Res, 60, pp.942~944 (1999)
  21. 김정식, "Comparison of success rates of orthodontic mini-screws by the insertion method", 대한치과교정학회지, 42(5), pp.242~248 (2012), 대한치과교정학회
  22. 차정열, "즉시 부하 교정용 미니임플랜트의 안정성 평가를 위한 PeriotestⓇ의 유효성", 대한치과교정학회지, 40(3), pp.167~175 (2010), 대한치과교정학회
  23. Aparicio C, "Validity and clinical significance of biomechanical testing of implant", bone interface, 2006, pp.17(Suppl 2), 2~7
  24. Kim SJ, "Temperature change in pig rib bone during implant site preparation by low-speed drilling", JOURNAL OF APPLIED ORAL SCIENCE, 18(5), pp.522~527 (2010)
  25. Marković A, "Heat generation during implant placement in low-density bone: effect of surgical technique, insertion torque and implant macro design", Clin Oral Implants Res, 24, pp.798~805 (2013)
  26. Friberg B, "Evaluation of bone density using cutting resistance measurements and microradiography:an in vitro study in pig ribs", Clin Oral Implants Res, 6, pp.164~171 (1995)

관련 논문AI추천