본문 바로가기
KERD
논문KCI 등재

Experimental study of noise level optimization in brain single-photon emission computed tomography images using non-local means approach with various reconstruction methods

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

The noise reduction algorithm using the non-local means (NLM) approach is very efficient in nuclear medicine imaging. In this study, the applicability of the NLM noise reduction algorithm in single-photon emission computed tomography (SPECT) images with a brain phantom and the optimization of the NLM algorithm by changing the smoothing factors according to various reconstruction methods are investigated. Brain phantom images were reconstructed using filtered back projection (FBP) and ordered subset expectation maximization (OSEM). The smoothing factor of the NLM noise reduction algorithm determined the optimal coefficient of variation (COV) and contrast-to-noise ratio (CNR) results at a value of 0.020 in the FBP and OSEM reconstruction methods. We confirmed that the FBP- and OSEM-based SPECT images using the algorithm applied with the optimal smoothing factor improved the COV and CNR by 66.94% and 8.00% on average, respectively, compared to those of the original image. In conclusion, an optimized smoothing factor was derived from the NLM approach-based algorithm in brain SPECT images and may be applicable to various nuclear medicine imaging techniques in the future.

Abstract

The noise reduction algorithm using the non-local means (NLM) approach is very efficient in nuclear medicine imaging. In this study, the applicability of the NLM noise reduction algorithm in single-photon emission computed tomography (SPECT) images with a brain phantom and the optimization of the NLM algorithm by changing the smoothing factors according to various reconstruction methods are investigated. Brain phantom images were reconstructed using filtered back projection (FBP) and ordered subset expectation maximization (OSEM). The smoothing factor of the NLM noise reduction algorithm determined the optimal coefficient of variation (COV) and contrast-to-noise ratio (CNR) results at a value of 0.020 in the FBP and OSEM reconstruction methods. We confirmed that the FBP- and OSEM-based SPECT images using the algorithm applied with the optimal smoothing factor improved the COV and CNR by 66.94% and 8.00% on average, respectively, compared to those of the original image. In conclusion, an optimized smoothing factor was derived from the NLM approach-based algorithm in brain SPECT images and may be applicable to various nuclear medicine imaging techniques in the future.

참고문헌 (24)

  1. 박훈희, "Usefulness of CT based SPECT Fusion Image in the lung Disease:Preliminary Study", 방사선기술과학, 35(1), pp.59~64 (2012), 대한방사선과학회
  2. 야마모토 토모아키, "Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT", 방사선기술과학, 31(4), pp.389~400 (2008), 대한방사선과학회
  3. W. Zheng, "Sparsity promoting regularization for effective noise suppression in SPECT image reconstruction", Inverse Probl, 35, pp.115011~ (2019)
  4. D. G. Amen, "Brain SPECT imaging in complex psychiatric cases: an evidencebased, underutilized Tool", Open Neuroimaging J, 5, pp.40~48 (2011)
  5. N. A. Nikolov, "Gaussian filter for brain SPECT imaging", Int. Biosyst. and Bioeng, 6, pp.4~15 (2022)
  6. P. P. Bruyant, "Analytic and iterative reconstruction algorithms in SPECT", J. Nucl. Med, 43, pp.1343~1358 (2002)
  7. S. Vandenberghe, "Iterative reconstruction algorithms in nuclear medicine", Comput. Med. Imag. Graph, 25, pp.105~111 (2001)
  8. A. C. Trevisan, "Comparison between OSEM and FBP reconstruction algorithms for the qualitative and quantitative interpretation of brain DAT-SPECT using an anthropomorphic striatal phantom : implications for the practice", Res. on Biomed. Eng, 36, pp.77~88 (2020)
  9. L. I. Ruudin, "Nonlinear total variation based noise removal algorithms", Physica D, 60, pp.259~268 (1992)
  10. H. V. Bhujle, "NLM based magnetic resonance image denoising e a review", Biomed. Signal Process Control, 47, pp.252~261 (2019)
  11. Bae-Guen Kim, "Noise Level and Similarity Analysis for Computed Tomographic Thoracic Image with Fast Non-Local Means Denoising Algorithm", Applied Sciences, 10(21), pp.7455~ (2020), MDPI AG[DOI]
  12. M. Y. Jang, "Experimental study of the fast non-local means noise reduction algorithm using the Hoffman 3D brain phantom in nuclear medicine SPECT image", Optik, 224, pp.165440~ (2020)
  13. Seong-Hyeon Kang, "Application of Fast Non-Local Means Algorithm for Noise Reduction Using Separable Color Channels in Light Microscopy Images", International Journal of Environmental Research and Public Health, 18(6), pp.2903~ (2021), MDPI AG[DOI]
  14. A. Buades, "A Non-local Algorithm for Image Denoising", IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) (2005)
  15. Donghyeok Choi, "Study of the Noise Reduction Algorithm with Median Modified Wiener Filter for T2-weighted Magnetic Resonance Brain Images", Journal of Magnetics, 26(1), pp.50~59 (2021), 한국자기학회
  16. 김규석, "Investigation of a blind-deconvolution framework after noise reduction using a gamma camera in nuclear medicine imaging", Nuclear Engineering and Technology, 52(11), pp.2594~2600 (2020), 한국원자력학회[DOI]
  17. A. Mittal, "Making a “completely blind” image quality analyzer", IEEE Signal Process. Lett, 20, pp.209~212 (2013)
  18. Praveenbalaji Rajendran, "Photoacoustic imaging aided with deep learning: a review", Biomedical Engineering Letters (BMEL), 12(2), pp.155~173 (2022), 대한의용생체공학회[DOI]
  19. L. Gondara, "Medical Image Denoising Using Convolutional Denoising Autoencoders", 2016 IEEE 16th International Conference on Data Mining Workshops (ICDMW) (2017)
  20. N. A. Olia, "Deep learningebased denoising of low-dose SPECT myocardial perfusion images : quantitative assessment and clinical performance", Eur. J. Nucl. Med. Mol. Imag, 49, pp.1508~1522 (2022)
  21. Jang Hyung Lee, "Bone age estimation using deep learning and hand X-ray images", Biomedical Engineering Letters (BMEL), 10(3), pp.323~331 (2020), 대한의용생체공학회[DOI]
  22. Cameron Wright, "Deep learning prediction of non-perfused volume without contrast agents during prostate ablation therapy", Biomedical Engineering Letters (BMEL), 13(1), pp.31~40 (2023), 대한의용생체공학회[DOI]
  23. Afzal Hussain Shahid, "A deep learning approach for prediction of Parkinson’s disease progression", Biomedical Engineering Letters (BMEL), 10(2), pp.227~239 (2020), 대한의용생체공학회[DOI]
  24. Mohamed A. A. Hegazy, "U-net based metal segmentation on projection domain for metal artifact reduction in dental CT", Biomedical Engineering Letters (BMEL), 9(3), pp.375~385 (2019), 대한의용생체공학회[DOI]

관련 논문AI추천

Newly-designed adaptive non-blind deconvolution with structural similarity index in single-photon emission computed tomography김규석, 이영진한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제12호Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain김규범, 김규석, 김연경, 이수환한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제10호노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화김이준, 박수빈, 박수연, 서강현, 오윤지, 이영진, 이우석, 정하선대한방사선과학회 · Journal of Radiological Science and Technology2024 · 제47권 제1호PET/MR 영상에서의 팬텀을 활용한 노이즈 감소를 위한 변형된 중간값 위너필터의 적용 효율성 연구박찬록, 이세정, 이영진, 조영현대한방사선과학회 · Journal of Radiological Science and Technology2021 · 제44권 제3호재구성 알고리즘과 Butterworth 필터 차단 주파수가 핵의학 영상 화질에 미치는 영향: Prominence Processor 기반 시뮬레이션 연구박찬록, 홍승연대한방사선과학회 · Journal of Radiological Science and Technology2025 · 제48권 제5호뇌 관류 SPECT 스캐너의 정도관리-균일도에 따른 팬텀 영상 평가김준, 김정수, 박찬록, 양현진대한방사선과학회 · Journal of Radiological Science and Technology2023 · 제46권 제1호

이 간행물의 다른 논문 (41건)