초록

The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

Abstract

The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

참고문헌 (17)

  1. Townsend DW, "Multimodality imaging of structure and function", Physics in Medicine and Biology, 53(4), pp.R1~R9 (2008)
  2. Boellaard R, "Qauality control for quantitative multicenter whole-body PET", MR studies : A NEMA image quality phantom study with three current PET, Medical Physics, pp.2015, 42[DOI]
  3. Grant AM, "NEMA NU 2-2012 performance studies for the SiPM-basd ToF PET component of the GE SIGNA PET", MR system, 2016, pp.43, 2334~2343
  4. Teuho J, "Comparison of single-scatter simulation and Monte Carlo single-scatter simulation on Philips Ingenuity TF PET", MR, MIC)[DOI]
  5. Zaidi H, "Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system", Physics in Medicine and Biology, 56, pp.3091~3106 (2011)
  6. Delso G, "PET", MRI system design, 2009, pp.36, S86~S92
  7. Hofmann M, "Towards quantitative PET", MRI: A review of MR-based attenuation correction techniques, 2009, pp.36, S93~S104
  8. Sharma A, "Image denoising using spatial domain filters : A quantitative study", IEEE 6th International Congress on Image and Signal Processing, 1, pp.293~298 (2013)
  9. 서강현, "The Effects of Total Variation (TV) Technique for Noise Reduction in Radio-Magnetic X-ray Image: Quantitative Study", Journal of Magnetics, 21(4), pp.593~598 (2016), 한국자기학회
  10. 이민석, "저선량 X-ray 영상의 잡음 제거를 위한 확률 거리 기반 3차원 비지역적 평균 알고리즘", 전자공학회논문지, 54(4), pp.61~67 (2017), 대한전자공학회
  11. Goldstein JS, "A multistage representation of the wiener filter based on orthogonal projections", IEEE Transactions on Information Theory, 44(7), pp.2943~2959 (1998)
  12. Borsdorf A, "Wavelet based noise reduction in CT-images using correlation analysis", IEEE Transactions on Medical Imaging, 27(12), pp.1685~1703 (2008)
  13. Kalender WA, "An algorithm for noise suppression in dual energy CT material density images", IEEE Transactions on Medical Imaging, 7(3), pp.218~224 (1988)
  14. 주성욱, "시뮬레이션된 성인 남성 인체모형 팬텀을 이용한 전산화단층촬영에서의 노이즈 제거를 위한 Median Modified Wiener 필터", 한국방사선학회논문지, 15(1), pp.21~28 (2021), 한국방사선학회[DOI]
  15. Park CR, "Optimization of mask size with median modified Wiener filter algorithm for gamma images using pixelated semiconductor detecor : Monte Carlo simulation study", Nuclear Instruments and Methods in Physics Research A, 980, pp.1~6 (2020)
  16. 이용기, "적층 제조형 방식의 3D 프린터로 제작한 뇌 팬텀의 유용성", 방사선기술과학, 43(6), pp.453~460 (2020), 대한방사선과학회
  17. 정의환, "핵의학 감마카메라 정도관리의 딥러닝 적용", 방사선기술과학, 43(6), pp.461~467 (2020), 대한방사선과학회

관련 논문AI추천

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition김재영, 박찬록, 안창현, 이영진한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제1호PET 영상의 잡음개선을 위한 적응적 공간 필터 개발최용, 김병태, 김상은, 박장춘, 송태용, 우상근, 이경한, 정진호, 최연성대한의용생체공학회 · 의공학회지2002 · 제23권 제3호Experimental study of noise level optimization in brain single-photon emission computed tomography images using non-local means approach with various reconstruction methods강성현, 이승완, 이영진한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제5호노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화김이준, 박수빈, 박수연, 서강현, 오윤지, 이영진, 이우석, 정하선대한방사선과학회 · Journal of Radiological Science and Technology2024 · 제47권 제1호Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain김규범, 김규석, 김연경, 이수환한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제10호자기 지도 학습훈련 기반의 Noise2Void 네트워크를 이용한 PET 영상의 잡음 제거 평가: 팬텀 실험박찬록, 윤석환대한방사선과학회 · Journal of Radiological Science and Technology2021 · 제44권 제6호