본문 바로가기
KERD
논문KCI 등재

Newly-designed adaptive non-blind deconvolution with structural similarity index in single-photon emission computed tomography

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Single-photon emission computed tomography SPECT image reconstruction methods have a significant influence on image quality, with filtered back projection (FBP) and ordered subset expectation maximization (OSEM) being the most commonly used methods. In this study, we proposed newly-designed adaptive non-blind deconvolution with a structural similarity (SSIM) index that can take advantage of the FBP and OSEM image reconstruction methods. After acquiring brain SPECT images, the proposed image was obtained using an algorithm that applied the SSIM metric, defined by predicting the distribution and amount of blurring. As a result of the contrast to noise ratio (CNR) and coefficient of variation evaluation (COV), the resulting image of the proposed algorithm showed a similar trend in spatial resolution to that of FBP, while obtaining values similar to those of OSEM. In addition, we confirmed that the CNR and COV values of the proposed algorithm improved by approximately 1.69 and 1.59 times, respectively, compared with those of the algorithm involving an inappropriate deblurring process. To summarize, we proposed a new type of algorithm that combines the advantages of SPECT image reconstruction techniques and is expected to be applicable in various fields

Abstract

Single-photon emission computed tomography SPECT image reconstruction methods have a significant influence on image quality, with filtered back projection (FBP) and ordered subset expectation maximization (OSEM) being the most commonly used methods. In this study, we proposed newly-designed adaptive non-blind deconvolution with a structural similarity (SSIM) index that can take advantage of the FBP and OSEM image reconstruction methods. After acquiring brain SPECT images, the proposed image was obtained using an algorithm that applied the SSIM metric, defined by predicting the distribution and amount of blurring. As a result of the contrast to noise ratio (CNR) and coefficient of variation evaluation (COV), the resulting image of the proposed algorithm showed a similar trend in spatial resolution to that of FBP, while obtaining values similar to those of OSEM. In addition, we confirmed that the CNR and COV values of the proposed algorithm improved by approximately 1.69 and 1.59 times, respectively, compared with those of the algorithm involving an inappropriate deblurring process. To summarize, we proposed a new type of algorithm that combines the advantages of SPECT image reconstruction techniques and is expected to be applicable in various fields

참고문헌 (33)

  1. 김규석, "Improvement of signal and noise performance using single image super-resolution based on deep learning in single photon-emission computed tomography imaging system", Nuclear Engineering and Technology, 53(7), pp.2341~2347 (2021), 한국원자력학회[DOI]
  2. Philipp Ritt, "Recent Developments in SPECT", CT, 2022, pp.52(3), 276~285[DOI]
  3. Laetitia Imbert, "CZT cameras: A technological jump for myocardial perfusion SPECT", Journal of Nuclear Cardiology, 23(4), pp.894~896 (2016), Elsevier BV[DOI]
  4. Dayong Wu, "Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure", Journal of Nuclear Cardiology, 26(2), pp.443~452 (2019), Elsevier BV[DOI]
  5. 이영진, "Comparison of Photon Counting and Conventional Scintillation Detectors in a Pinhole SPECT System for Small Animal Imaging: Monte Carlo Simulation Studies", Journal of the Korean Physical Society, 62(9), pp.1317~1322 (2013), 한국물리학회
  6. Jan V. Hoffmann, "Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging", EJNMMI Physics, 7(1), pp.64~ (2020), Springer Science and Business Media LLC[DOI]
  7. 야마모토 토모아키, "Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT", 방사선기술과학, 31(4), pp.389~400 (2008), 대한방사선과학회
  8. Maria Lyra, "Filtering in SPECT Image Reconstruction", International Journal of Biomedical Imaging, 2011, pp.1~14 (2011), Hindawi Limited[DOI]
  9. A. Katua, "Optimization of ordered subset expectation maximization reconstruction for reducing urinary bladder artifacts in single-photon emission computed tomography imaging", World Journal of Nuclear Medicine, 10(01), pp.3~8 (2011), Georg Thieme Verlag KG[DOI]
  10. O. H. Winz, "Image quality and data quantification in dopamine transporter SPECT:advantage of 3-dimensional OSEM reconstruction?", Clin. Nucl. Med, 37, pp.866~871 (2012)[DOI]
  11. Gengsheng L. Zeng, "A filtered backprojection algorithm with characteristics of the iterative landweber algorithm", Medical Physics, 39(2), pp.603~607 (2012), Wiley[DOI]
  12. K. Van Laere, "Image filtering in single-photon emission computed tomography: principles and applications", Computerized Medical Imaging and Graphics, 25(2), pp.127~133 (2001), Elsevier BV[DOI]
  13. Z. Wang, "Image Quality Assessment: From Error Visibility to Structural Similarity", IEEE Transactions on Image Processing, 13(4), pp.600~612 (2004), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
  14. Wufeng Xue, "Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index", IEEE Transactions on Image Processing, 23(2), pp.684~695 (2014), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
  15. J. R. Dame Carroll, "Airway dimensions measured from micro-computed tomography and high-resolution computed tomography", European Respiratory Journal, 28(4), pp.712~720 (2006), European Respiratory Society (ERS)[DOI]
  16. Kihwan Choi, "Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)", Medical Physics, 37(9), pp.5113~5125 (2010), Wiley[DOI]
  17. Martijn M. A. Dietze, "Accelerated SPECT image reconstruction with FBP and an image enhancement convolutional neural network", EJNMMI Physics, 6(1), pp.14~ (2019), Springer Science and Business Media LLC[DOI]
  18. A. P. Dempster, "Maximum Likelihood from Incomplete Data Via the <i>EM<", i> Algorithm, 1977, pp.39(1), 1~22[DOI]
  19. L. A. Shepp, "Maximum Likelihood Reconstruction for Emission Tomography", IEEE Transactions on Medical Imaging, 1(2), pp.113~122 (1982), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
  20. C. Kamphuis, "Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm", IEEE Transactions on Medical Imaging, 17(6), pp.1101~1105 (1998), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
  21. H Erdogan, "Ordered subsets algorithms for transmission tomography", Physics in Medicine and Biology, 44(11), pp.2835~2851 (1999), IOP Publishing[DOI]
  22. Freek J Beekman, "Ordered subset reconstruction for x-ray CT", Physics in Medicine and Biology, 46(7), pp.1835~1844 (2001), IOP Publishing[DOI]
  23. T.F. Chan, "Active contours without edges", IEEE Transactions on Image Processing, 10(2), pp.266~277 (2001), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
  24. Ross T. Whitaker, "A level-set approach to 3D reconstruction from range data", International Journal of Computer Vision, 29(3), pp.203~231 (1998), Springer Science and Business Media LLC[DOI]
  25. P. Soille, "Morphological Image Analysis: Principles and Applications", pp.173~174 (1999), Springer-Verlag
  26. Cécile Louchet, "Total Variation as a Local Filter", SIAM Journal on Imaging Sciences, 4(2), pp.651~694 (2011), Society for Industrial & Applied Mathematics (SIAM)[DOI]
  27. Min-Hee Lee, "Image restoration algorithm incorporating methods to remove noise and blurring from positron emission tomography imaging for Alzheimer's disease diagnosis", Physica Medica, 103, pp.181~189 (2022), Elsevier BV[DOI]
  28. Stanley H. Chan, "An augmented Lagrangian method for video restoration", 2011 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), 20, pp.3097~3111 (2011), IEEE
  29. Jung Hun Lee, "Coefficient of variation on Gd-EOB MR imaging: Correlation with the presence of early-stage hepatocellular carcinoma in patients with chronic hepatitis B", European Journal of Radiology, 102, pp.95~101 (2018), Elsevier BV[DOI]
  30. M Koutalonis, "Contrast-to-noise ratio in magnification mammography: a Monte Carlo study", Physics in Medicine and Biology, 52(11), pp.3185~3199 (2007), IOP Publishing[DOI]
  31. Floris H P van Velden, "Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for High-Resolution Research Tomograph studies: effects of randoms estimation methods", Physics in Medicine and Biology, 53(12), pp.3217~3230 (2008), IOP Publishing[DOI]
  32. G A Kastis, "Evaluation of a spline reconstruction technique: Comparison with FBP, MLEM and OSEM", IEEE Nuclear Science Symposuim &amp; Medical Imaging Conference (2010), IEEE
  33. octreotate in patients with neuroendocrine tumors, "Nucl. Med. Rev. Cent. E Eur", 2013, 9~16, https:

관련 논문AI추천

이 간행물의 다른 논문 (39건)