본문 바로가기
KERD
논문

가습기 폐질환(Humidifier Lung)의 환경적 원인 인자 고찰

Review of Humidifier Lung Cases Caused by Use of Humidifier - Focusing on Probable Environmental Causal Agents -

1

조회

0

다운로드

5

인용

0

참고문헌

키워드

초록

Background: In Korea, there is low awareness of the respiratory health problems caused by the use of humidifiers, leading to a lack of governmental measures. Objectives: The objectives of this study were to review cases of varying degrees of humidifier lung and fever in connection with the use of humidifiers and to summarize the probable environmental agents causing these cases. Methods: We searched all articles reporting on humidifier lung, humidifier fever, and humidifier diseases caused by the use of a humidifier both at home and in the workplace. Results: We summarized a number of cases of varying degrees of respiratory diseases resulting from inhalation of water mist of humidifiers containing various species of bacteria and fungi and their toxins. Type of respiratory disease connected with humidifier lung includes interstitial pneumonitis, hypersensitivity pneumonitis, fever and several respiratory symptoms. Non-tuberculous mycobacteria (NTM), Actinomycetes, endotoxins and contaminated humidifier water were the most commonly suspected probable environmental agents causing humidifier lung. In Korea, the use of humidifier biocide is suspected as a likely cause of fatal lung injury including death and lung transplantation. Conclusion: Governmental policy should be devised and measures including a national surveillance system should be taken to prevent humidifier lung caused by the use of humidifiers.

Abstract

Background: In Korea, there is low awareness of the respiratory health problems caused by the use of humidifiers, leading to a lack of governmental measures. Objectives: The objectives of this study were to review cases of varying degrees of humidifier lung and fever in connection with the use of humidifiers and to summarize the probable environmental agents causing these cases. Methods: We searched all articles reporting on humidifier lung, humidifier fever, and humidifier diseases caused by the use of a humidifier both at home and in the workplace. Results: We summarized a number of cases of varying degrees of respiratory diseases resulting from inhalation of water mist of humidifiers containing various species of bacteria and fungi and their toxins. Type of respiratory disease connected with humidifier lung includes interstitial pneumonitis, hypersensitivity pneumonitis, fever and several respiratory symptoms. Non-tuberculous mycobacteria (NTM), Actinomycetes, endotoxins and contaminated humidifier water were the most commonly suspected probable environmental agents causing humidifier lung. In Korea, the use of humidifier biocide is suspected as a likely cause of fatal lung injury including death and lung transplantation. Conclusion: Governmental policy should be devised and measures including a national surveillance system should be taken to prevent humidifier lung caused by the use of humidifiers.

참고문헌 (65)

  1. Interim Report of Epidemiological Investigation on Lung Injury with Unknown Cause in Korea, "Korea CDC", KCDC, 1~2 (2011)
  2. 최예용, "가습기살균제 피해사건과 교훈", 한국환경보건학회지, 38(02), pp.166~174 (2012), 한국환경보건학회[DOI]
  3. Cases Of health Problems due to the Use of Humidifier Biocide, "KSEH", Korean Society for Environmental Health, ~ (2012)
  4. Banaszak EF, "Hypersensitivity Pneumonitis due to Contamination of an Air Conditioner", New England Journal of Medicine, 283, pp.271~276 (1970)
  5. Fink JN, "Interstitial Pneumonitis due to Hypersensitivity to an Organism Contaminating a Heating System", Annals of Internal Medicine, 74, pp.80~83 (1971)
  6. Pickering C, "Investigation of a Respiratory Disease Associated with an Air?conditioning System", Clinical & Experimental Allergy, 6, pp.109~118 (1976)
  7. Van Assendelft A, "Humidifier-Associated Extrinsic Allergic Alveolitis", Scand J Work Environ Health, 5, pp.35~41 (1979)
  8. Miller MM, "Chronic Hypersensitivity Lung Disease with Recurrent Episodes of Hypersensitivity Pneumonitis due to a Contaminated Central Humidifier", Clinical & Experimental Allergy, 6, pp.451~462 (1976)
  9. Anderson K, "Climate, Intermittent Humidification, and Humidifier Fever", British Journal of Industrial Medicine, 46, pp.671~674 (1989)
  10. Ohinishi H, "Humidifier Lung: Possible Contribution of Endotoxin-Induced Lung Injury", Internal Medicine, 41, pp.1179~1182 (2002)
  11. Rylander R, "Airborne Endotoxins and Humidifier Disease", Clinical & Experimental Allergy, 14, pp.109~112 (1984)
  12. Rylander R, "Humidifier Fever and Endotoxin Exposure", Clinical & Experimental Allergy, 8, pp.511~516 (1978)
  13. Flaherty DK, "A Cytophaga Species Endotoxin as a Putative Agent of Occupation- Related Lung Disease", Infection and Immunity, 43, pp.213~216 (1984)
  14. Daftary AS, "Inhalational Lung Injury Associated with Humidifier “White Dust”", Pediatrics, 127, pp.e509~e512 (2011)
  15. Sweet LC, "Hypersensitivity Pneumonitis Related to a Home Furnace Humidifier", Journal of Allergy and Clinical Immunology, 48, pp.171~178 (1971)
  16. Suda T, "Hypersensitivity Pneumonitis Associated with Home Ultrasonic Humidifiers", Chest, 107, pp.711~717 (1995)
  17. Burke GW, "Allergic Alveolitis Caused by Home Humidifiers", JAMA: The Journal of the American Medical Association, 238, pp.2705~2708 (1977)
  18. Tourville D, "Hypersensitivity Pneumonitis due to Contamination of Home Humidifier", Journal of Allergy and Clinical Immunology, 49, pp.245~251 (1972)
  19. Friend J, "Extrinsic Allergic Alveolitis and Contaminated Cooling-Water in a Factory Machine", The Lancet, 309, pp.297~300 (1977)
  20. Fink JN, "Interstitial Lung Disease due to Contamination of Forced Air Systems", Annals of Internal Medicine, 84, pp.406~413 (1976)
  21. Marras TK, "Hypersensitivity Pneumonitis Reaction to Mycobacterium Avium in Household Water", Chest, 127, pp.664~671 (2005)
  22. Flaherty DK, "Bacterial Endotoxin Isolated from a Water Spray Air Humidification System as a Putative Agent of Occupation-Related Lung Disease", Infection and Immunity, 43, pp.206~212 (1984)
  23. Asan Medical Center., "Hospital Based Case-Control Study on the Lung Injury with Unknown Causes", Public Health Wkly Rep. KCDC, 4, pp.825~829 (2011)
  24. Kane GC, "Hypersensitivity Pneumonitis Secondary to Klebsiella Oxytoca", A New Cause of Humidifier Lung. CHEST Journal, 104, pp.627~629 (1993)
  25. Baur X, "Humidifier Lung and Humidifier Fever", Lung, 166, pp.113~124 (1988)
  26. Edwards J, "Protozoa as Sources of Antigen in ‘humidifier Fever’", ~ (1976)
  27. Seabury J, "Characterization of Thermophilic Actinomycetes Isolated from Residential Heating and Humidification Systems", Journal of Allergy and Clinical Immunology, 51, pp.161~173 (1973)
  28. Pal T, "Lung Function of Workers Exposed to Antigens from a Contaminated Air-Conditioning System", International Archives of Occupational and Environmental Health, 55, pp.253~266 (1985)
  29. Kahana LM, "Mycobacterium Avium Complex Infection in an Immunocompetent Young Adult Related to Hot Tub Exposure", Chest, 111, pp.242~245 (1997)
  30. Speizer FE., "Occupational and Environmental Lung Diseases: An Overview", Environmental Health Perspectives, 108, pp.603~ (2000)
  31. Weiss L, "Respiratory Illness in Workers Exposed to Metalworking Fluid Contaminated with Nontuberculous Mycobacteria-Ohio, 2001", JAMA, 287, pp.3073~3074 (2002)
  32. Embil J, "Pulmonary Illness Associated with Exposure to Mycobacterium-Avium Complex in Hot Tub Water", Chest, 111, pp.813~816 (1997)
  33. Falkinham JO, "Impact of Human Activities on the Ecology of Nontuberculous Mycobacteria", Future Microbiology, 5, pp.951~960 (2010)
  34. Falkinham III JO., "Mycobacterial Aerosols and Respiratory Disease", Emerging Infectious Diseases, 9, pp.763~ (2003)
  35. Falkinham Iii J, "Surrounded by Mycobacteria: Nontuberculous Mycobacteria in the Human Environment", Journal of Applied Microbiology, 107, pp.356~367 (2009)
  36. Falkinham III JO, "Nontuberculous Mycobacteria in the Environment", Clinics in Chest Medicine, 23, pp.529~552 (2002)
  37. Lacey J, "Bioaerosols and Occupational Lung Disease", Journal of Aerosol Science, 25, pp.1371~1404 (1994)
  38. Douwes J, "Bioaerosol Health Effects and Exposure Assessment: Progress and Prospects", Annals of Occupational Hygiene, 47, pp.187~200 (2003)
  39. Rylander R., "The Role of Endotoxin for Reactions After Exposure to Cotton Dust", American Journal of Industrial Medicine, 12, pp.687~697 (1987)
  40. Heederik D, "Towards an Occupational Exposure Limit for Endotoxin?", ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 4, pp.17~19 (1997)
  41. Douwes J, "Bioaerosol Health Effects and Exposure Assessment: Progress and Prospects", Annals of Occupational Hygiene, 47, pp.187~200 (2003)
  42. Jacek D, "Bacteria and Fungi in Organic Dust as Potential Health Hazard", Annals of Agricultural and Environmental Medicine, 4, pp.11~16 (1997)
  43. Freeman A, "Hypersensitivity Pneumonitis in a Machinist", Am J Ind Med, 34, pp.387~392 (1998)
  44. Rosenman KD., "Asthma, Hypersensitivity Pneumonitis and Other Respiratory Diseases Caused by Metalworking Fluids", Current Opinion in Allergy and Clinical Immunology, 9, pp.97~ (2009)
  45. Rosenman KD, "Work- Related Asthma and Respiratory Symptoms among Workers Exposed to Metal-Working Fluids", Am J Ind Med, 32, pp.325~331 (1997)
  46. Hodgson MJ, "Hypersensitivity Pneumonitis in a Metal□working Environment", American Journal of Industrial Medicine, 39, pp.616~628 (2001)
  47. Trout D, "Evaluation of Hypersensitivity Pneumonitis among Workers Exposed to Metal Removal Fluids", Applied Occupational and Environmental Hygiene, 18, pp.953~960 (2003)
  48. Thorne PS, "Metalworking Fluid with Mycobacteria and Endotoxin Induces Hypersensitivity Pneumonitis in Mice", Am J Respir Crit Care Med, 173, pp.759~768 (2006)
  49. Use and Care of Home Humidifier, "US EPA", ~, pp.Indoor Air Facts No 8:ANR-445-W: (1991)
  50. Alvarez-Fernandez J, "Hypersensitivity Pneumonitis due to an Ultrasonic Humidifier", Allergy, 53, pp.210~212 (1998)
  51. Shiue S, "Hypersensitivity Pneumonitis Associated with the use of Ultrasonic Humidifiers", New York State Journal of Medicine, 90, pp.263~265 (1990)
  52. 박동욱, "방수 스프레이 흡입 노출로 인한 급성 호흡기 중독 사례 및 원인 고찰", 한국환경보건학회지, 38(6), pp.451~459 (2012), 한국환경보건학회[DOI]
  53. Miller MM, "Chronic Hypersensitivity Lung Disease with Recurrent Episodes of Hypersensitivity Pneumonitis due to a Contaminated Central Humidifier", Clinical & Experimental Allergy, 6, pp.451~462 (1976)
  54. Kohler PF, "Humidifier Lung Hypersensitivity Pneumonitis Related to Thermotolerant Bacterial Aerosols", CHEST Journal, 69, pp.294~296 (1976)
  55. Suda T, "Hypersensitivity Pneumonitis Associated with Home Ultrasonic Humidifiers", Chest, 107, pp.711~717 (1995)
  56. Marras TK, "Hypersensitivity Pneumonitis Reaction to Mycobacterium Avium in Household Water", Chest, 127, pp.664~671 (2005)
  57. Friend J, "Extrinsic Allergic Alveolitis and Contaminated Cooling-Water in a Factory Machine", The Lancet, 309, pp.297~300 (1977)
  58. Edwards J., "Microbial and Immunological Investigations and Remedial Action After an Outbreak of Humidifier Fever", British Journal of Industrial Medicine, 37, pp.55~62 (1980)
  59. Cockcroft A, "An Investigation of Operating Theatre Staff Exposed to Humidifier Fever Antigens", British Journal of Industrial Medicine, 38, pp.144~151 (1981)
  60. Flaherty DK, "Bacterial Endotoxin Isolated from a Water Spray Air Humidification System as a Putative Agent of Occupation-Related Lung Disease", Infection and Immunity, 43, pp.206~212 (1984)
  61. Burge PS, "Occupational Asthma in a Factory with a Contaminated Humidifier", Thorax, 40, pp.248~254 (1985)
  62. Robertson A, "Extrinsic Allergic Alveolitis Caused by a Cold Water Humidifier", Thorax, 42, pp.32~37 (1987)
  63. Pal TM, "The Clinical Spectrum of Humidifier Disease in Synthetic Fiber Plants", American Journal of Industrial Medicine, 31, pp.682~692 (1997)
  64. Kateman E, "Relationship of Airborne Microorganisms with the Lung Function and Leucocyte Levels of Workers with a History of Humidifier Fever", Scandinavian Journal of Work, Environment & Health, pp.428~433 (1990)

관련 논문AI추천

가습기 살균제 폐 손상 피해자의 살균제 노출 특성 -태아와 임산부 노출을 중심으로 -이은, 김선경, 노현석, 도경현, 류승훈, 박동욱, 배문주, 백도명, 신동천, 안종주, 임흥규, 조재림, 차원석, 최예용, 홍상범, 홍수종한국환경보건학회 · 한국환경보건학회지2016 · 제42권 제3호가습기 살균제 제품의 건강위험 고찰 - 제품 수와 살균제 성분을 중심으로 -김소연, 김지원, 박동욱, 박지훈, 이승희, 임흥규, 조경이한국환경보건학회 · 한국환경보건학회지2020 · 제46권 제5호연도별 가습기 살균제 피해자 분포 고찰 - 폐 손상 중심노현석, 류승훈, 박동욱한국환경보건학회 · 한국환경보건학회지2016 · 제42권 제6호2008년부터 가습기 살균제 건강 피해 급증: 우연인가, 필연인가?박동욱, 박소영, 박주현, 박지훈, 백도명, 홍수종한국환경보건학회 · 한국환경보건학회지2020 · 제46권 제2호Chloromethylisothiazolinone (CMIT)과 Methylisothiazolinone (MIT)의 건강영향에 대한 고찰 - 가습기 살균제 폐 손상을 중심으로 -권정환, 김지원, 류승훈, 박동욱, 박소영, 박지훈, 이소연한국환경보건학회 · 한국환경보건학회지2020 · 제46권 제3호Evaluation report on the causal association between humidifier disinfectants and lung injury박혜숙, 신승수, 이순영, 정해관, 최보율, 하미나, 황승식한국역학회 · Epidemiology and Health2016 · 제38권

이 간행물의 다른 논문 (9건)