HG-AAS법에 의한 요중 비소의 최적 분석법에 관한 연구
A Study on the Optimal Analytical Method for the Determination of Urinary Arsenic by Hydride Generation-Atomic Absorption Spectrometry
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
This study was carried out to examine the optimal analytical method for determination of urinary toxic arsenic (inorganic arsenic and its metabolites) by HG-AAS (hydride generation-atomic absorption spectrometry). In the analysis of SRMs (standard reference materials), method E (addition of 0.4% L-cysteine to pre-reductant and use 0.04M HCl as carrier acid) showed the most accurate results compared with the reference values. In the analysis of 30 urinary samples, analytical results were significantly different depend on the component of pre-reductant and the concentration of carrier acid. When the concentration of carrier acid was higher, the analytical result was lower. The recovery rates of MMA (monomethylarsonic acid) and DMA (dimethylarsenic acid) were varied by the concentration of pre-treatment acid and carrier acid and hydride generation reagents. When the concentration of carrier acid was 1.62 M (5% HCl), the recovery rates of DMA was 1%. The recovery rates of MMA and DMA in method E (=V) were 102% and 100%, respectively. The results of this study suggest that the component and concentration of pre-reductant and carrier acid must be carefully adjusted in the analysis of urinary arsenic, and method E is recommendable as the most precise analytical method for determination of urinary toxic arsenic.
Abstract
This study was carried out to examine the optimal analytical method for determination of urinary toxic arsenic (inorganic arsenic and its metabolites) by HG-AAS (hydride generation-atomic absorption spectrometry). In the analysis of SRMs (standard reference materials), method E (addition of 0.4% L-cysteine to pre-reductant and use 0.04M HCl as carrier acid) showed the most accurate results compared with the reference values. In the analysis of 30 urinary samples, analytical results were significantly different depend on the component of pre-reductant and the concentration of carrier acid. When the concentration of carrier acid was higher, the analytical result was lower. The recovery rates of MMA (monomethylarsonic acid) and DMA (dimethylarsenic acid) were varied by the concentration of pre-treatment acid and carrier acid and hydride generation reagents. When the concentration of carrier acid was 1.62 M (5% HCl), the recovery rates of DMA was 1%. The recovery rates of MMA and DMA in method E (=V) were 102% and 100%, respectively. The results of this study suggest that the component and concentration of pre-reductant and carrier acid must be carefully adjusted in the analysis of urinary arsenic, and method E is recommendable as the most precise analytical method for determination of urinary toxic arsenic.
참고문헌 (33)
- Murphy, E. A, "An assessment of the amounts of arsenical pesticides used historically in a geographical area", Science of the Total Environment, 218, pp.89~101 (1998)
- Jeong, K, "Occupational diseases", pp.435~ (1999), Korea Medicine Press
- Jones, F. T, "A broad view of arsenic", Poultry Science, 86, pp.2~14 (2007)
- Kee, H. S, "An anti-clastogenic role of selenium in arsenic- and chromiuminduced oxidative stress causing chromosomal damages", Korean Journal of Environmental Health, 23(4), pp.9~15 (1997)
- Mandal, B. K, "Arsenic round the world: a r eview", Talanta, 58, pp.201~235 (2002)
- McSheehy, S, "Speciation of arsenic in edible algae by bi-dimensional size-exclusion anion exchange HPLC with dual ICP-MS and electrospray MS", MS detection, 2000, pp.1, 79~87
- Brima , E. I, "Understanding arsenic metabolism through spectroscopic determination of arsenic in human urine", Spectroscopy, 20, pp.125~151 (2006)
- Hata, A, "HPLC-ICP-MS speciation analysis of arsenic in urine of Japanese subjects without occupational exposure", Journal of Occupational Health, 49, pp.217~223 (2007)
- "ATSDR (Agency for Toxic Substances and Disease Registry)"[URL]
- Lindberg, A, "Evaluation of the three most commonly used analytical methods for determination of inorganic arsenic and its metabolites in urine", Toxicology Letters, 168(3), pp.310~318 (2006)
- Evaluation of exposure levels to environmental pollutants and biomonitoring of biological samples in Sihwa·Banwol and Ulsan area. Annual Report, 2007, "The National Institute of Environmental Research", ~ (2008)
- Survey on health status of residents in the closed mine in Choongnam and Choongpook area. Final report, "Ministry of Environment of the Republic of Korea", Ministry of Environment, ~ (2008)
- Le, X. C, "Effect of cysteine on the speciation of arsenic by using hydride generation atomic absorption spectrometry", Analytica Chimica Acta, 285, pp.277~285 (1994)
- Shraim, A, "Speciation of arsenic by hydride generation-atomic absorption spectrometry (HG-AAS) in hydrochloric acid medium", Talanta, 50, pp.1109~1127 (1999)
- Carrero, P, "Determination of various arsenic species by flow injection hydride generation atomic absorption spectrometry; Investigation of the effects of the acid concentration of different reaction media on the generation of arsines", Analytica Chimica Acta, 438, pp.195~204 (2001)
- 송명진, "HG-AAS에 의한 무기비소 분석 시 예비환원제의 최적화 조건과 분석에 미치는 영향", 분석과학, 18(5), pp.396~402 (2005), 한국분석과학회
- Feng, Y. L, "Off-line separation and determination of inorganic arsenic species in natural water by high resolution inductively coupled plasma mass spectrometry with hydride generation combined with reaction of arsenic(V) and L-cysteine", Analytica Chimica Acta, 375, pp.167~175 (1998)
- TLVs and BEIs, "ACGIH", Arsenic and soluble inorganic compounds, ~ (2001)
- Arbouine, M. W, "The effect of seafood consumption on the assessment of occupational exposure to arsenic by urinary arsenic speciation measurements", Journal of Trace Elements and Electrolytes in Health and Disease, 6, pp.153~160 (1992)
- Larsen, E. H, "Specia - tion of eight arsenic compounds in human urine by high-performance liquid chromatography with inductively coupled plasma mass spectrometric detection using antimonate for internal chromatographic standardization", Journal of Analytical Atomic Spectrometry, 8, pp.557~563 (1993)
- Larsen, E. H, "Arsenic speciation in seafood samples with emphasis on minor constituents; An investigation using high-performance liquid chromatography with detection by inductively coupled plasma mass spectrometry", Journal of Analytical Atomic Spectrometry, 8, pp.1075~1084 (1993)
- Buchet, J. P, "Assessment of exposure to inorganic arsenic following ingestion of marine organisms by volunteers", Environmental Research, 66, pp.44~51 (1994)
- Branch, N, "Determination of arsenic species in fish by directly coupled high-performance liquid chromatography-inductively coupled plasma mass spectrometry", Journal of Analytical Atomic Spectrometry, 9, pp.33~37 (1994)
- Safety evaluation of arsenic. Final report, "Park, J. D", Korea Food & Drug Administration, ~, pp.GOVP1200508249 (2002)
- Evaluation of the uptake dose of pollutants form major foods in Korea and risk assessment, "Park, S. O", Korea Food & Drug Administration, ~ (2006)
- Guo, T, "F a st a utomated determination of toxicologically relevant arsenic in urine by flow injection-hydride generation atomic absorption spectrometry", Analytica Chimica Acta, 349, pp.313~318 (1997)
- Tsalev, D. L, "Flowinjection hydride generation atomic absorption spectrometric study of the automated on-line pre-reduction of arsenate, methylarsonate and dimethylarsinate and high-performance liquid chromatographic separation of their l-cysteine complexes", Talanta, 51(6), pp.1059~1068 (2000)
- Lim, H. S, "Effects of acid and prereductant in the analysis of arsenic by hydride generation- atomic absorption spectrometry", Analytical Science & Technology, 13(2), pp.151~157 (2000)
- Tseng, C. H, "Arsenic exposure, urinary arsenic speciation, and peripheral vascular disease in blackfoot diseasehyperendemic villages in Taiwan", Toxicology and Applied Pharmacology, 206, pp.299~308 (2005)
- Hsueh, Y. M, "U rina ry a rsenic speciation in subjects with or without restriction from seafood dietary intake", Toxicology Letters, 133, pp.83~91 (2002)
- Shraim, A, "Arsenic speciation in the urine and hair of individuals exposed to airborne arsenic through coal-burning in Guizhou, PR China", Toxicology Letters, 137, pp.35~48 (2003)
- Xie, Y. X, "Element concentrations in urine of patients suffering from chronic arsenic poisoning", The Tohoku Journal of Experimental Medicine, 193, pp.229~235 (2001)
- Yamato, N, "Concentration and chemical species of arsenic in human urine and hair", Bulletin of Environmental Contamination and Toxicology, 40, pp.633~640 (1998)
