본문 바로가기
KERD
논문KCI 등재

Effectiveness of 32-element Surface Coil Array for Accelerated Volume Targeted Breath-Hold Coronary MRA

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose : To compare 12 and 32-element surface coil arrays for highly accelerated coronary magnetic resonance angiography (MRA) using parallel imaging. Materials and Methods : Steady state free precession coronary MRA was performed in 5 healthy volunteers at 1.5 T whole body MR scanner using both 12 and 32-element surface coil arrays. Left anterior descending and right coronary artery data sets were acquired for each volunteer. Data sets were sub-sampled for parallel imaging using reduction factors from 1 to 6. Mean geometry factor (g-factor), maximum g-factor, and artifact level were calculated for each of the two coil arrays. Results : Over all reduction factors, the mean and maximum g-factors and artifact level were significantly reduced using the 32-element array compared to the 12-element array (P << 0.1). The mean g-factor was sensitive to the imaging orientations of coronary arteries while the maximum g-factor and artifact level were independent of orientation. Conclusion : The 32-element surface coil array significantly improves artifact and noise suppression for highly accelerated coronary MRA using parallel imaging. The increased acceleration factors made feasible with the 32-element array offer the potential to enhance spatial resolution or increase volumetric coverage for 3D coronary MRA.

Abstract

Purpose : To compare 12 and 32-element surface coil arrays for highly accelerated coronary magnetic resonance angiography (MRA) using parallel imaging. Materials and Methods : Steady state free precession coronary MRA was performed in 5 healthy volunteers at 1.5 T whole body MR scanner using both 12 and 32-element surface coil arrays. Left anterior descending and right coronary artery data sets were acquired for each volunteer. Data sets were sub-sampled for parallel imaging using reduction factors from 1 to 6. Mean geometry factor (g-factor), maximum g-factor, and artifact level were calculated for each of the two coil arrays. Results : Over all reduction factors, the mean and maximum g-factors and artifact level were significantly reduced using the 32-element array compared to the 12-element array (P << 0.1). The mean g-factor was sensitive to the imaging orientations of coronary arteries while the maximum g-factor and artifact level were independent of orientation. Conclusion : The 32-element surface coil array significantly improves artifact and noise suppression for highly accelerated coronary MRA using parallel imaging. The increased acceleration factors made feasible with the 32-element array offer the potential to enhance spatial resolution or increase volumetric coverage for 3D coronary MRA.

참고문헌 (10)

  1. Pruessmann KP, "Boesiger P.SENSE: sensitivity encoding for fast MRI", Magn Reson Med, 42(5), pp.952~962 (1999)
  2. Sodickson DK, "Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays", Magn Reson Med, 38(4), pp.591~603 (1997)
  3. Park J, "Feasibility and performance of breath-hold 3D true-FISP coronary MRA using self-calibrating parallel acquisition", Magn Reson Med, 52(1), pp.7~13 (2004)
  4. Huber ME, "Sensitivity-encoded coronary MRA at 3T", Magn Reson Med, 52(2), pp.221~227 (2004)
  5. Weiger M, "Specific coil design for SENSE: a six-element cardiac array", Magn Reson Med, 45(3), pp.495~504 (2001)
  6. Fattahi S, "Pushing The Speed Limit in SENSE using Novel Sampling Strategies. In: 2nd International Workshop on Parallel MRI" (2005), Zurich
  7. Xu D, "Optimal Sampling of k-Space withCartesian Grids for Parallel MR Imaging", Proceedings of the 11th Annual Meeting of ISMRM, Miami, pp.2450~ (2005)
  8. Lin FH, "Parallel imaging reconstruction using automatic regularization", Magn Reson Med, 51(3), pp.559~567 (2004)
  9. Niendorf T, "Highly Accelerated Single Breath-Hold Coronary MRA with Whole Heart Coverage using a Cardiac Optimized 32-element Coil Array", Proceedings of the 13th Annual Meething of ISMRM, Miami, pp.702~ (2005)
  10. Paul D, "Comparison of different flip angle variation functions for improved signal behavior in SSFP sequences", In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, pp.2663~ (2004)

관련 논문AI추천

Two-Dimensional Image-Based Respiratory Navigator for Free- Breathing Coronary Magnetic Resonance Angiography신태훈대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2018 · 제22권 제1호Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols고정민, 이배영, 정정임대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2013 · 제17권 제2호Advances in Fast Vessel-Wall Magnetic Resonance Imaging Using High-Density Coil ArraysNan Li, Sen Jia, Xiaoliang Zhang, Xuetong Yin, Ye Li대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2021 · 제25권 제4호Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion SensitivityBerthold Kiefer, Christian Geppert, Girish Fatterpekar, Hersh Chandarana1, kai tobias block, Mari Hagiwara, Mary Bruno, Robert Grimm, Sarah Milla, Tom Mulholland대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2014 · 제18권 제2호선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가김소현, 김형진, 서재준, 이동훈, 이만우, 이춘형, 한봉수, 홍철표대한의용생체공학회 · 의공학회지2011 · 제32권 제3호Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia김민지, 김성목, 박성지, 백소현, 최연현대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2017 · 제21권 제1호

이 간행물의 다른 논문 (14건)