본문 바로가기
KERD
논문KCI 등재

Advances in Fast Vessel-Wall Magnetic Resonance Imaging Using High-Density Coil Arrays

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Arteriosclerosis is the leading cause of stroke, with a fatality rate surpassing that of ischemic heart disease. High-resolution vessel wall magnetic resonance imaging is generally recognized as a non-invasive and panoramic method for the evaluation of arterial plaque; however, this method requires improved signal-tonoise ratio and scanning speed. Recent advances in high-density head and neck coil arrays are characterized by broad coverage, multiple channels, and closefitting designs. This review analyzes fast magnetic resonance imaging from the perspective of accelerated algorithms for vessel wall imaging and demonstrates the need for effective algorithms for signal acquisition using advanced radiofrequency system. We summarize different phased-array structures under various experimental objectives and equipment conditions, introduce current research results, and propose prospective research studies in the future.

Abstract

Arteriosclerosis is the leading cause of stroke, with a fatality rate surpassing that of ischemic heart disease. High-resolution vessel wall magnetic resonance imaging is generally recognized as a non-invasive and panoramic method for the evaluation of arterial plaque; however, this method requires improved signal-tonoise ratio and scanning speed. Recent advances in high-density head and neck coil arrays are characterized by broad coverage, multiple channels, and closefitting designs. This review analyzes fast magnetic resonance imaging from the perspective of accelerated algorithms for vessel wall imaging and demonstrates the need for effective algorithms for signal acquisition using advanced radiofrequency system. We summarize different phased-array structures under various experimental objectives and equipment conditions, introduce current research results, and propose prospective research studies in the future.

참고문헌 (141)

  1. World Health Organization, "The top 10 causes of death", World Health Organization, ~ (2020)
  2. Zhou Z, "Evaluation of 3D multi-contrast joint intra-and extracranial vessel wall cardiovascular magnetic resonance", J Cardiovasc Magn Reson, 17, pp.41~ (2015)
  3. Qureshi AI, "Intracranial atherosclerosis", Lancet, 383, pp.984~998 (2014)
  4. Li Y, "One-stop MR neurovascular vessel wall imaging with a 48-channel coil system at 3 T", IEEE Trans Biomed Eng, 67, pp.2317~2327 (2020)
  5. Lin M, "Chinese guideline for standard utilization of imaging for cerebrovascular diseases", Chin J Radiol, 53, pp.916~940 (2019)
  6. Mandell DM, "Intracranial vessel wall MRI : principles and expert consensus recommendations of the American Society of Neuroradiology", AJNR Am J Neuroradiol, 38, pp.218~229 (2017)
  7. Xihai Z, "Expert consensus on techniques and application of intracranial MR vessel wall imaging in China", Chin J Radiol, 53, pp.1045~1059 (2019)
  8. Saba L, "Carotid artery wall imaging : perspective and guidelines from the asnr vessel wall imaging study group and expert consensus recommendations of the American Society of Neuroradiology", AJNR Am J Neuroradiol, 39, pp.E9~E31 (2018)
  9. Zhao X, "Prevalence and characteristics of carotid artery high-risk atherosclerotic plaques in Chinese patients with cerebrovascular symptoms : a Chinese atherosclerosis risk evaluation II study", J Am Heart Assoc, 6, pp.e005831~ (2017)
  10. Hu X, "A 32-channel coil system for MR vessel wall imaging of intracranial and extracranial arteries at 3T", Magn Reson Imaging, 36, pp.86~92 (2017)
  11. Jose Daniel Hernandez Chang, "A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging", Investigative Magnetic Resonance Imaging, 24(3), pp.95~122 (2020), 대한자기공명의과학회
  12. Cohen-Adad J, "32-channel RF coil optimized for brain and cervical spinal cord at 3 T", Magn Reson Med, 66, pp.1198~1208 (2011)
  13. Roemer PB, "The NMR phased array", Magn Reson Med, 16, pp.192~225 (1990)
  14. Li Y, "ICE decoupling technique for RF coil array designs", Med Phys, 38, pp.4086~4093 (2011)
  15. Feinberg DA, "Halving MR imaging time by conjugation: demonstration at 3.5 kG", Radiology, 161, pp.527~531 (1986)
  16. Haacke EM, "A fast, iterative, partialfourier technique capable of local phase recovery", J Magn Reson(1969), 92, pp.126~145 (1991)
  17. Noll DC, "Homodyne detection in magnetic resonance imaging", IEEE Trans Med Imaging, 10, pp.154~163 (1991)
  18. Pruessmann KP, "SENSE : sensitivity encoding for fast MRI", Magn Reson Med, 42, pp.952~962 (1999)
  19. Sodickson DK, "Simultaneous acquisition of spatial harmonics(SMASH) : fast imaging with radiofrequency coil arrays", Magn Reson Med, 38, pp.591~603 (1997)
  20. Jakob PM, "AUTOSMASH:a self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics", MAGMA, 7, pp.42~54 (1998)
  21. Heidemann RM, "VDAUTO-SMASH imaging", Magn Reson Med, 45, pp.1066~1074 (2001)
  22. Griswold MA, "Generalized autocalibrating partially parallel acquisitions(GRAPPA)", Magn Reson Med, 47, pp.1202~1210 (2002)
  23. Donoho DL, "Compressed sensing", IEEE Trans Information Theory, 52, pp.1289~1306 (2006)
  24. Lustig M, "Sparse MRI : the application of compressed sensing for rapid MR imaging", Magn Reson Med, 58, pp.1182~1195 (2007)
  25. Liang D, "Accelerating SENSE using compressed sensing", Magn Reson Med, 62, pp.1574~1584 (2009)
  26. Zhu B, "Image reconstruction by domain-transform manifold learning", Nature, 555, pp.487~492 (2018)
  27. Jin KH, "Deep convolutional neural network for inverse problems in imaging", IEEE Trans Image Process, 26, pp.4509~4522 (2017)
  28. Breuer FA, "Controlled aliasing in volumetric parallel imaging(2D CAIPIRINHA)", Magn Reson Med, 55, pp.549~556 (2006)
  29. Qiao Y, "Intracranial arterial wall imaging using three-dimensional high isotropic resolution black blood MRI at 3.0 Tesla", J Magn Reson Imaging, 34, pp.22~30 (2011)
  30. Xie Y, "Improved blackblood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation", Magn Reson Med, 75, pp.2286~2294 (2016)
  31. Zhang L, "High resolution three dimensional intracranial arterial wall imaging at 3 T using T1 weighted SPACE", Magn Reson Imaging, 33, pp.1026~1034 (2015)
  32. Wang H, "Parameter optimization framework on wave gradients of Wave-CAIPI imaging", Magn Reson Med, 83, pp.1659~1672 (2020)
  33. Qiu Z, "Highly accelerated parallel MRI using wave encoding and virtual conjugate coils", Magn Reson Med, 86, pp.1345~1359 (2021)
  34. Yuan J, "Three-dimensional blackblood multi-contrast carotid imaging using compressed sensing : a repeatability study", MAGMA, 31, pp.183~190 (2018)
  35. Zhu C, "Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing(CS-SPACE)", MAGMA, 31, pp.457~467 (2018)
  36. Jia S, "Joint intracranial and carotid vessel wall imaging in 5 minutes using compressed sensing accelerated DANTE-SPACE", Eur Radiol, 30, pp.119~127 (2020)
  37. Liu Y, "Projected iterative soft-thresholding algorithm for tight frames in compressed sensing magnetic resonance imaging", IEEE Trans Med Imaging, 35, pp.2130~2140 (2016)
  38. Ravishankar S, "MR image reconstruction from highly undersampled k-space data by dictionary learning", IEEE Trans Med Imaging, 30, pp.1028~1041 (2011)
  39. Aharon M, "K-SVD : an algorithm for designing overcomplete dictionaries for sparse representation", IEEE Trans Signal Process, 54, pp.4311~4322 (2006)
  40. Lai Z, "Image reconstruction of compressed sensing MRI using graph-based redundant wavelet transform", Med Image Anal, 27, pp.93~104 (2016)
  41. Zhan Z, "Fast multiclass dictionaries learning with geometrical directions in MRI reconstruction", IEEE Trans Biomed Eng, 63, pp.1850~1861 (2016)
  42. Cai JM, "Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging", Circulation, 106, pp.1368~1373 (2002)
  43. Li F, "The association of lesion eccentricity with plaque morphology and components in the superficial femoral artery: a high-spatial-resolution, multi-contrast weighted CMR study", J Cardiovasc Magn Reson, 12, pp.37~ (2010)
  44. Lai Z, "Sparse MRI reconstruction using multi-contrast image guided graph representation", Magn Reson Imaging, 43, pp.95~104 (2017)
  45. Gong E, "PROMISE : parallel-imaging and compressed-sensing reconstruction of multicontrast imaging using SharablE information", Magn Reson Med, 73, pp.523~535 (2015)
  46. Koolstra K, "Accelerating compressed sensing in parallel imaging reconstructions using an efficient circulant preconditioner for cartesian trajectories", Magn Reson Med, 81, pp.670~685 (2019)
  47. Jia S, "Highly accelerated vessel wall imaging using CAIPIRINHA accelerated SPACE and IFR-CS", Proceedings of the 28th Annual Meeting of ISMRM, pp.1325~ (2020)
  48. Kim TH, "LORAKS makes better SENSE : phase-constrained partial fourier SENSE reconstruction without phase calibration", Magn Reson Med, 77, pp.1021~1035 (2017)
  49. Haldar JP, "P-LORAKS : low-rank modeling of local k-space neighborhoods with parallel imaging data", Magn Reson Med, 75, pp.1499~1514 (2016)
  50. Wang S, "Accelerating magnetic resonance imaging via deep learning", Proc IEEE Int SympBiomed Imaging, 2016, pp.514~517 (2016)
  51. Yang G, "DAGAN : deep de-aliasing generative adversarial networks for fast compressed sensing MRI reconstruction", IEEE Trans Med Imaging, 37, pp.1310~1321 (2018)
  52. Quan TM, "Compressed sensing MRI reconstruction using a generative adversarial network with a cyclic loss", IEEE Trans Med Imaging, 37, pp.1488~1497 (2018)
  53. Yang Y, "ADMM-CSNet : a deep learning approach for image compressive sensing", IEEE Trans Pattern Anal Mach Intell, 42, pp.521~538 (2020)
  54. Kwon K, "A parallel MR imaging method using multilayer perceptron", Med Phys, 44, pp.6209~6224 (2017)
  55. Uecker M, "Image reconstruction by regularized nonlinear inversion--joint estimation of coil sensitivities and image content", Magn Reson Med, 60, pp.674~682 (2008)
  56. Liang D, "Deep magnetic resonance image reconstruction : inverse problems meet neural networks", IEEE Signal Process Mag, 37, pp.141~151 (2020)
  57. Wang S, "Deep learning for fast MR imaging : a review for learning reconstruction from incomplete k-space data", Biomed Signal Process Control, 68, pp.102579~ (2021)
  58. Lee D, "Deep residual learning for compressed sensing MRI", Proc IEEE Int Symp Biomed Imaging, pp.15~18 (2017)
  59. Lindenholz A, "The use and pitfalls of intracranial vessel wall imaging : how we do it", Radiology, 286, pp.12~28 (2018)
  60. Cheng J, "Improved parallel image reconstruction using feature refinement", Magn Reson Med, 80, pp.211~223 (2018)
  61. Chen Q, "A dedicated 36-channel receive array for fetal MRI at 3T", IEEE Trans Med Imaging, 37, pp.2290~2297 (2018)
  62. Li N, "Simultaneous head and spine MR imaging in children using a dedicated multichannel receiver system at 3T", IEEE Trans Biomed Eng, 68, pp.3659~3670 (2021)
  63. Gruber B, "RF coils : a practical guide for nonphysicists", J Magn Reson Imaging, 48, pp.590~604 (2018)
  64. Ritz K, "Cause and mechanisms of intracranial atherosclerosis", Circulation, 130, pp.1407~1414 (2014)
  65. Wang Y, "Prevalence and outcomes of symptomatic intracranial large artery stenoses and occlusions in China : the Chinese intracranial atherosclerosis(CICAS)study", Stroke, 45, pp.663~669 (2014)
  66. Setsompop K, "Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty", Magn Reson Med, 67, pp.1210~1224 (2012)
  67. Bookwalter CA, "Analysis of signal-to-noise behavior in Cartesian continuous sampling sequences : predictions and experimental validation of opportunities for improved image SNR", Magn Reson Med, 58, pp.819~824 (2007)
  68. Vasanawala SS, "Advances in pediatric body MRI", Pediatr Radiol, 41(Suppl 2), pp.549~554 (2011)
  69. Saib G, "Time-of-flight angiography at 7T using TONE double spokes with parallel transmission", Magn Reson Imaging, 61, pp.104~115 (2019)
  70. Wiggins GC, "32-channel 3 Tesla receive-only phasedarray head coil with soccer-ball element geometry", Magn Reson Med, 56, pp.216~223 (2006)
  71. Wiggins GC, "96-channel receive-only head coil for 3 Tesla : design optimization and evaluation", Magn Reson Med, 62, pp.754~762 (2009)
  72. Porter JR, "A 16-element phasedarray head coil", Magn Reson Med, 40, pp.272~279 (1998)
  73. Lattanzi R, "Performance evaluation of a 32-element head array with respect to the ultimate intrinsic SNR", NMR Biomed, 23, pp.142~151 (2010)
  74. Reiss-Zimmermann M, "Improvement of SNR and acquisition acceleration using a 32-channel head coil compared to a 12-channel head coil at 3T", Acta Radiol, 54, pp.702~708 (2013)
  75. Wiesinger F, "Electrodynamics and ultimate SNR in parallel MR imaging", Magn Reson Med, 52, pp.376~390 (2004)
  76. Wiesinger F, "Approaching ultimate SNR with finite coil arrays", Proceedings of the 13th Annual Meeting of ISMRM, pp.672~ (2005)
  77. Vaidya MV, "Approaching ultimate intrinsic SNR in a uniform spherical sample with finite arrays of loop coils", Concepts Magn Reson Part B Magn Reson Eng, 44, pp.53~65 (2014)
  78. Keil B, "Massively parallel MRI detector arrays", J Magn Reson, 229, pp.75~89 (2013)
  79. Han H, "Integrated parallel reception, excitation, and shimming (iPRES)", Magn Reson Med, 70, pp.241~247 (2013)
  80. Keil B, "A 64-channel 3T array coil for accelerated brain MRI", Magn Reson Med, 70, pp.248~258 (2013)
  81. Mahmutovic M, "A 64-channel brain array coil with an integrated 16-channel field monitoring system for 3T MRI", Proceedings of the 29th Annual Meeting of ISMRM, pp.0623~ (2021)
  82. Li Y, "Design and testing of a 24-channel head coil for MR imaging at 3T", Magn Reson Imaging, 58, pp.162~173 (2019)
  83. Cogswell PM, "Application of adaptive image receive coil technology for whole-brain imaging", AJR Am J Roentgenol, 216, pp.552~559 (2021)
  84. Kong Q, "7T TOF-MRA shows modulated orifices of lenticulostriate arteries associated with atherosclerotic plaques in patients with lacunar infarcts", Eur J Radiol, 118, pp.271~276 (2019)
  85. Ugurbil K, "Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array", Magn Reson Med, 82, pp.495~509 (2019)
  86. Hendriks AD, "Potential acceleration performance of a 256-channel whole-brain receive array at 7 T", Magn Reson Med, 81, pp.1659~1670 (2019)
  87. Li Y, "In-vivo human brain imaging at 5 T using a 48 channel Tx-Rx array", Proceedings of the 29th Annual Meeting of ISMRM, pp.1572~ (2021)
  88. Pang Y, "Tilted microstrip phased arrays with improved electromagnetic decoupling for ultrahigh-field magnetic resonance imaging", Medicine(Baltimore), 93, pp.e311~ (2014)
  89. Zhang X, "Microstrip RF surface coil design for extremely high-field MRI and spectroscopy", Magn Reson Med, 46, pp.443~450 (2001)
  90. Yan X, "Closely-spaced double-row microstrip RF arrays for parallel MR imaging at ultrahigh fields", Appl Magn Reson, 46, pp.1239~1248 (2015)
  91. Zhang X, "A microstrip transmission line volume coil for human head MR imaging at 4T", J Magn Reson, 161, pp.242~251 (2003)
  92. Avdievich NI, "Evaluation of short folded dipole antennas as receive elements of ultra-high-field human head array", Magn Reson Med, 82, pp.811~824 (2019)
  93. Connell IRO, "Shape optimization of an electric dipole array for 7 Tesla neuroimaging", IEEE Trans Med Imaging, 38, pp.2177~2187 (2019)
  94. Avdievich NI, "Decoupling of folded-end dipole antenna elements of a 9.4 T human head array using an RF shield", NMR Biomed, 33, pp.e4351~ (2020)
  95. Clément JD, "A human cerebral and cerebellar 8-channel transceive RF dipole coil array at 7T", Magn Reson Med, 81, pp.1447~1458 (2019)
  96. Yan X, "Hybrid monopole", loop coil array for human head MR imaging at 7T, 2015, pp.46, 541~550
  97. Avdievich NI, "Combination of surface and 'vertical' loop elements improves receive performance of a human head transceiver array at 9.4 T", NMR Biomed, 31 (2018)
  98. Adriany G, "Transmit and receive transmission line arrays for 7 Tesla parallel imaging", Magn Reson Med, 53, pp.434~445 (2005)
  99. Von Morze C, "An eight-channel, nonoverlapping phased array coil with capacitive decoupling for parallel MRI at 3 T", Concepts Magn Reson B : Magn, 31, pp.37~43 (2007)
  100. Tavaf N, "A self-decoupled 32-channel receive array for human-brain MRI at 10.5 T", Magn Reson Med, 86, pp.1759~1772 (2021)
  101. Hayes CE, "Surface coil phased arrays for high-resolution imaging of the carotid arteries", J Magn Reson Imaging, 6, pp.109~112 (1996)
  102. Liffers A, "Geometrical optimization of a phased array coil for highresolution MR imaging of the carotid arteries", Magn Reson Med, 50, pp.439~443 (2003)
  103. Ouhlous M, "Quadrature coil design for high-resolution carotid artery imaging scores better than a dual phased-array coil design with the same volume coverage", J Magn Reson Imaging, 25, pp.1079~1084 (2007)
  104. Hadley JR, "Relative RF coil performance in carotid imaging", Magn Reson Imaging, 23, pp.629~639 (2005)
  105. Balu N, "Improvements in carotid plaque imaging using a new eight-element phased array coil at 3T", J Magn Reson Imaging, 30, pp.1209~1214 (2009)
  106. Kraff O, "A transmit", receive radiofrequency array for imaging the carotid arteries at 7 Tesla : coil design and first in vivo results, 2011, pp.46, 246~254
  107. Hu X, "An 8-channel RF coil array for carotid artery MR imaging in humans at 3 T", Med Phys, 43, pp.1897~ (2016)
  108. Tate Q, "Increased vessel depiction of the carotid bifurcation with a specialized 16-channel phased array coil at 3T", Magn Reson Med, 69, pp.1486~1493 (2013)
  109. Zhang Q, "Comparison of four MR carotid surface coils at 3T", PLoS One, 14, pp.e0213107~ (2019)
  110. Yuan C, "In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques", Circulation, 104, pp.2051~2056 (2001)
  111. Koning W, "Highresolution MRI of the carotid arteries using a leaky waveguide transmitter and a high-density receive array at 7 T", Magn Reson Med, 69, pp.1186~1193 (2013)
  112. Beck MJ, "Interchangeable neck shape-specific coils for a clinically realizable anterior neck phased array system", Magn Reson Med, 78, pp.2460~2468 (2017)
  113. Ruytenberg T, "A flexible five-channel shielded-coaxial-cable(SCC)transceive neck coil for high-resolution carotid imaging at 7T", Magn Reson Med, 84, pp.1672~1677 (2020)
  114. Zamarayeva AM, "Custom, spray coated receive coils for magnetic resonance imaging", Sci Rep, 11, pp.2635~ (2021)
  115. Ruytenberg T, "Design and characterization of receive-only surface coil arrays at 3T with integrated solid high permittivity materials", J Magn Reson, 311, pp.106681~ (2020)
  116. Bernstein F, "A phased array coil optimized for carotid artery imaging", Proceedings of the International Society for Magnetic Resonance in Medicine, pp.163~ (1999)
  117. Anumula S, "Highresolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla", Acad Radiol, 12, pp.1521~1526 (2005)
  118. Sapkota N, "Eight-channel decoupled array for cervical spinal cord imaging at 3T: six-channel posterior and two-channel anterior array coil", Concepts Magn Reson Part B, 46B, pp.90~99 (2016)
  119. Papoutsis K, "A purposebuilt neck coil for black-blood DANTE-prepared carotid artery imaging at 7T", Magn Reson Imaging, 40, pp.53~61 (2017)
  120. Zhang Z, "Visualization of the lenticulostriate arteries at 3T using black-blood T1-weighted intracranial vessel wall imaging : comparison with 7T TOF-MRA", Eur Radiol, 29, pp.1452~1459 (2019)
  121. Liu Y, "High resolution contrast-enhanced magnetic resonance angiography of carotid arteries using an array coil on a cardiovascular scanner", Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 4, pp.2864~2865 (2000)
  122. Hu Z, "Motion-compensated 3D turbo spin-echo for more robust MR intracranial vessel wall imaging", Magn Reson Med, 86, pp.637~647 (2021)
  123. Wang X, "A new designed 36-channel neurovascular coil at 3T", Proceedings of the 20th Annual Meeting of ISMRM, pp.2787~ (2012)
  124. Fan Z, "Carotid arterial wall MRI at 3T using 3D variable-flip-angle turbo spin-echo(TSE)with flow-sensitive dephasing(FSD)", J Magn Reson Imaging, 31, pp.645~654 (2010)
  125. Avdievich NI, "Decoupling of a tight-fit transceiver phased array for human brain imaging at 9.4T: loop overlapping rediscovered", Magn Reson Med, 79, pp.1200~1211 (2018)
  126. Gao Y, "A 16-channel AC", DC array coil for anesthetized monkey whole-brain imaging at 7T, 2020, pp.207, 116396~
  127. Han J, "Decoupling of multi-channels RF coil and its application to intraoperative MR-guided focused ultrasound device", 2010 International Conference of Medical Image Analysis and Clinical Application, pp.91~94 (2010)
  128. Shajan G, "Design and evaluation of an RF front-end for 9.4 T human MRI", Magn Reson Med, 66, pp.596~604 (2011)
  129. Quan Z, "A 16-channel loop array for in vivo macaque whole-brain imaging at 3 T", Magn Reson Imaging, 68, pp.167~172 (2020)
  130. Yan X, "Self-decoupled radiofrequency coils for magnetic resonance imaging", Nat Commun, 9, pp.3481~ (2018)
  131. Lakshmanan K, "The "Loopole" antenna: a hybrid coil combining loop and electric dipole properties for ultrahigh-field MRI", Concepts Magn Reson Part B Magn Reson Eng, 2020, pp.8886543~ (2020)
  132. Wu B, "Interconnecting L", C components for decoupling and its application to lowfield open MRI array, 2007, pp.31B, 116~126
  133. Wu B, "Capacitively decoupled tunable loop microstrip(TLM)array at 7 T", Magn Reson Imaging, 25, pp.418~424 (2007)
  134. Li N, "Electromagnetic field and radio frequency circuit co-simulation for magnetic resonance imaging dual-tuned radio frequency coils", IEEE Trans Magn, 54, pp.5100504~ (2018)
  135. Li N, "A fast electromagnetic field and radio frequency circuit co-simulation approach for strongly coupled coil array in magnetic resonance imaging", IEEE Trans Magn, 54, pp.5100905~ (2018)
  136. Yan X, "Eight-channel monopole array using ICE decoupling for human head MR imaging at 7 T", Appl Magn Reson, 47, pp.527~538 (2016)
  137. Yan X, "7T transmit", receive arrays using ICE decoupling for human head MR imaging, 2014, pp.33, 1781~1787
  138. Li N, "Investigation of a dual-tuned RF coil array decoupled using ICE technique for 1 H", 19 F MR imaging at 3T, 2020, pp.56, 1~4
  139. Connell IR, "Design of a parallel transmit head coil at 7T with magnetic wall distributed filters", IEEE Trans Med Imaging, 34, pp.836~845 (2015)
  140. Yan X, "New resonator geometries for ICE decoupling of loop arrays", J Magn Reson, 277, pp.59~67 (2017)
  141. Sui J, "A self-decoupled antenna array using inductive and capacitive couplings cancellation", IEEE Trans Antennas Propag, 68, pp.5289~5296 (2020)

관련 논문AI추천

이 간행물의 다른 논문 (11건)