Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breathhold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients (65.4 ± 12.3 years, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume(SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging (15 ± 7 sec vs. 293 ± 104 sec, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Abstract

Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breathhold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients (65.4 ± 12.3 years, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume(SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging (15 ± 7 sec vs. 293 ± 104 sec, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

참고문헌 (25)

  1. Rokey R, "Monitoring of acutely ill patients during nuclear magnetic resonance imaging : use of a time-varying filter electrocardiographic gating device to reduce gradient artifacts", Magn Reson Med, 6, pp.240~245 (1988)
  2. Juergens KU, "Left ventricular function studied with MDCT", Eur Radiol, 16, pp.342~357 (2006)
  3. Bak SH, "Assessment of global left ventricular function with dualsource computed tomography in patients with valvular heart disease", Acta Radiol, 53, pp.270~277 (2012)
  4. Niendorf T, "Highly accelerated cardiovascular MR imaging using many channel technology : concepts and clinical applications", Eur Radiol, 18, pp.87~102 (2008)
  5. Wintersperger BJ, "Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging : impact of acceleration factors on image quality and volumetric accuracy", J Magn Reson Imaging, 23, pp.222~227 (2006)
  6. Cawley PJ, "Cardiovascular magnetic resonance imaging for valvular heart disease : technique and validation", Circulation, 119, pp.468~478 (2009)
  7. Nassenstein K, "Single breathhold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine", Eur Radiol, 20, pp.2341~2347 (2010)
  8. Vincenti G, "Compressed sensing single-breath-hold CMR for fast quantification of LV function, volumes, and mass", JACC Cardiovasc Imaging, 7, pp.882~892 (2014)
  9. Saremi F, "Optimizing cardiac MR imaging : practical remedies for artifacts", Radiographics, 28, pp.1161~1187 (2008)
  10. Pruessmann KP, "SENSE : sensitivity encoding for fast MRI", Magn Reson Med, 42, pp.952~962 (1999)
  11. Bassett EC, "Evaluation of highly accelerated real-time cardiac cine MRI in tachycardia", NMR Biomed, 27, pp.175~182 (2014)
  12. Cerqueira MD, "Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association", Circulation, 105, pp.539~542 (2002)
  13. Nucifora G, "Prevalence and prognostic value of concealed structural abnormalities in patients with apparently idiopathic ventricular arrhythmias of left versus right ventricular origin : a magnetic resonance imaging study", Circ Arrhythm Electrophysiol, 7, pp.456~462 (2014)
  14. Kozerke S, "Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods", J Cardiovasc Magn Reson, 10, pp.29~ (2008)
  15. Theisen D, "High-resolution cine MRI with TGRAPPA for fast assessment of left ventricular function at 3 Tesla", Eur J Radiol, 82, pp.e219~e224 (2013)
  16. Wintersperger BJ, "Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function", Eur Radiol, 17, pp.73~80 (2007)
  17. Duarte R, "Assessment of left ventricular diastolic function with cardiovascular MRI : what radiologists should know", Diagn Interv Radiol, 18, pp.446~453 (2012)
  18. Feng L, "Highly accelerated realtime cardiac cine MRI using k-t SPARSE-SENSE", Magn Reson Med, 70, pp.64~74 (2013)
  19. Niendorf T, "Parallel imaging in cardiovascular MRI : methods and applications", NMR Biomed, 19, pp.325~341 (2006)
  20. Chandler AG, "Correction of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registration", J Cardiovasc Magn Reson, 10, pp.13~ (2008)
  21. Breuer FA, "Dynamic autocalibrated parallel imaging using temporal GRAPPA(TGRAPPA)", Magn Reson Med, 53, pp.981~985 (2005)
  22. Nael K, "High spatialresolution CE-MRA of the carotid circulation with parallel imaging: comparison of image quality between 2 different acceleration factors at 3.0 Tesla", Invest Radiol, 41, pp.391~399 (2006)
  23. Heilmaier C, "Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling", Eur J Radiol, 74, pp.492~499 (2010)
  24. Eberle HC, "Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique(TPAT)and 4D guide-point modelling analysis of left ventricular function", Eur Radiol, 20, pp.73~80 (2010)
  25. Hunold P, "Parallel acquisition techniques in cardiac cine magnetic resonance imaging using TrueFISP sequences : comparison of image quality and artifacts", J Magn Reson Imaging, 20, pp.506~511 (2004)

관련 논문AI추천

Biases in the Assessment of Left Ventricular Function by Compressed Sensing Cardiovascular Cine MRI김판기, 박진호, 안창범, 양영중, 윤종현, 최병욱대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2019 · 제23권 제2호Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods이활, 박은아, 정진욱, 채승훈대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2013 · 제17권 제3호Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols고정민, 이배영, 정정임대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2013 · 제17권 제2호Dynamic Cardiac Magnetic Resonance Fingerprinting During Vasoactive Breathing Maneuvers: First ResultsElizabeth Hillier, Jesse Hamilton, Kady Fischer, Luuk H.G.A. Hopman, Matthias G. Friedrich, Nicole Seiberlich, Yuchi Liu한국심초음파학회 · Journal of Cardiovascular Imaging2023 · 제31권 제2호Diastolic Function in Patients with Hypertrophic Cardiomyopathy: Evaluation Using the Phase-contrast MRI Measurement of Mitral Valve and Pulmonary Vein Flow Velocities김성목, 김은영, 오재건, 이상철, 장성아, 최연현대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2014 · 제18권 제4호Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future DirectionsLi Feng, Martin Uecker, Xiaoqing Wang대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2021 · 제25권 제4호

이 간행물의 다른 논문 (9건)