Two-Dimensional Image-Based Respiratory Navigator for Free- Breathing Coronary Magnetic Resonance Angiography
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To develop a two-dimensional (2D) image-based respiratory motion correction technique for free-breathing coronary magnetic resonance angiography (MRA). Materials and Methods: The proposed respiratory navigator obtained aliased a 2D sagittal image from under-sampled k-space data and utilized motion correlation between the aliased images. The proposed navigator was incorporated into the conventional coronary MRA sequence including the diaphragm navigator and tested in three healthy subjects. Results: The delineation of major coronary arteries was significantly improved using the proposed 2D motion correction (S/I and A/P) compared to one-dimensional (S/I) correction using the conventional diaphragm navigator. Conclusion: The 2D image-based respiratory navigator was proposed for freebreathing coronary angiography and showed the potential for improving respiratory motion correction compared to the conventional 1D correction.
Abstract
Purpose: To develop a two-dimensional (2D) image-based respiratory motion correction technique for free-breathing coronary magnetic resonance angiography (MRA). Materials and Methods: The proposed respiratory navigator obtained aliased a 2D sagittal image from under-sampled k-space data and utilized motion correlation between the aliased images. The proposed navigator was incorporated into the conventional coronary MRA sequence including the diaphragm navigator and tested in three healthy subjects. Results: The delineation of major coronary arteries was significantly improved using the proposed 2D motion correction (S/I and A/P) compared to one-dimensional (S/I) correction using the conventional diaphragm navigator. Conclusion: The 2D image-based respiratory navigator was proposed for freebreathing coronary angiography and showed the potential for improving respiratory motion correction compared to the conventional 1D correction.
참고문헌 (13)
- Stuber M, "Coronary magnetic resonance angiography", J Magn Reson Imaging, 26, pp.219~234 (2007)[DOI]
- Chiribiri A, "Coronary imaging with cardiovascular magnetic resonance: current state of the art", Prog Cardiovasc Dis, 54, pp.240~252 (2011)[DOI]
- Stehning C, "Freebreathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction", Magn Reson Med, 54, pp.476~480 (2005)[DOI]
- Danias PG, "Prospective navigator correction of image position for coronary MR angiography", Radiology, 203, pp.733~736 (1997)[DOI]
- Danias PG, "Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging", AJR Am J Roentgenol, 172, pp.1061~1065 (1999)[DOI]
- Nehrke K, "Free-breathing cardiac MR imaging: study of implications of respiratory motion--initial results", Radiology, 220, pp.810~815 (2001)[DOI]
- Taylor AM, "Calculation of a subject-specific adaptive motioncorrection factor for improved real-time navigator echogated magnetic resonance coronary angiography", J Cardiovasc Magn Reson, 1, pp.131~138 (1999)[DOI]
- Keegan J, "Coronary artery motion with the respiratory cycle during breathholding and free-breathing: implications for slice-followed coronary artery imaging", Magn Reson Med, 47, pp.476~481 (2002)[DOI]
- Lai P, "A dual-projection respiratory self-gating technique for whole-heart coronary MRA", J Magn Reson Imaging, 28, pp.612~620 (2008)[DOI]
- Lai P, "A respiratory self-gating technique with 3D-translation compensation for freebreathing whole-heart coronary MRA", Magn Reson Med, 62, pp.731~738 (2009)
- Brittain JH, "Coronary angiography with magnetizationprepared T2 contrast", Magn Reson Med, 33, pp.689~696 (1995)[DOI]
- Cunningham CH, "Novel design for notched RF saturation pulses using the SLR transform", Proceedings of the 15th Scientific Meeting of International Society for Magnetic Resonance in Medicine, 1709 (2007)
- Manke D, "Respiratory motion in coronary magnetic resonance angiography: a comparison of different motion models", J Magn Reson Imaging, 15, pp.661~671 (2002)[DOI]
