Image Quality and Focal Lesion Detectability Analysis of Multiband Variable-Rate Selective Excitation Diffusion-Weighted Imaging of the Liver Using 3.0-T MRI
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: Acquisition time reduction in diffusion-weighted imaging (DWI) can be achieved by the combining multiband and variable-rate selective excitation (MB-VERSE). This study attempted to evaluate and compare the image quality (IQ) and focal lesion detectability of the respiratory-triggered MB-VERSE DWI with conventional DWI for liver magnetic resonance imaging. Materials and Methods: The acquisition time, IQ, and focal lesion detectability of MBVERSE DWI and conventional DWI were compared in 144 patients. Qualitative (overall IQ, IQ at the liver dome, sharpness of the liver margin, and degree of artifacts) and quantitative (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and apparent diffusion coefficient) IQ parameters were compared with the Wilcoxon signed-rank test. The diagnostic accuracy for focal lesion detectability was estimated with the mean figure of merit (FOM) from the area under the jackknife alternative free-response receiver operating characteristic curve. Results: The MB-VERSE DWI exhibited significantly shorter scan time (153.1 ± 34.5 s vs. 225.1 ± 33.0 s, p < 0.001), poorer qualitative IQ (3.4 vs. 3.9, p < 0.001), lower SNR (34.4 vs. 50.0, p < 0.001), but comparable CNR (57.5 ± 49.0 vs. 78.9 ± 75.6, p = 0.070) compared to those of the conventional DWI. The MB-VERSE DWI exhibited similar per-lesion sensitivities (85.1%–88.1% vs. 88.1%–92.5%) and specificities (99.7%–99.8% vs. 99.5%–99.8%) of focal lesion detectability (p > 0.050) and similar diagnostic accuracy (FOM, 0.958 vs. 0.957, p = 0.583) compared to those of the conventional DWI. Conclusion: MB-VERSE DWI exhibited a significantly shorter acquisition time than conventional DWI, with compromised overall IQ and lower SNR but preserved CNR and focal liver lesion detectability. MB-VERSE DWI may be a useful alternative for patients requiring a short acquisition time.
Abstract
Purpose: Acquisition time reduction in diffusion-weighted imaging (DWI) can be achieved by the combining multiband and variable-rate selective excitation (MB-VERSE). This study attempted to evaluate and compare the image quality (IQ) and focal lesion detectability of the respiratory-triggered MB-VERSE DWI with conventional DWI for liver magnetic resonance imaging. Materials and Methods: The acquisition time, IQ, and focal lesion detectability of MBVERSE DWI and conventional DWI were compared in 144 patients. Qualitative (overall IQ, IQ at the liver dome, sharpness of the liver margin, and degree of artifacts) and quantitative (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and apparent diffusion coefficient) IQ parameters were compared with the Wilcoxon signed-rank test. The diagnostic accuracy for focal lesion detectability was estimated with the mean figure of merit (FOM) from the area under the jackknife alternative free-response receiver operating characteristic curve. Results: The MB-VERSE DWI exhibited significantly shorter scan time (153.1 ± 34.5 s vs. 225.1 ± 33.0 s, p < 0.001), poorer qualitative IQ (3.4 vs. 3.9, p < 0.001), lower SNR (34.4 vs. 50.0, p < 0.001), but comparable CNR (57.5 ± 49.0 vs. 78.9 ± 75.6, p = 0.070) compared to those of the conventional DWI. The MB-VERSE DWI exhibited similar per-lesion sensitivities (85.1%–88.1% vs. 88.1%–92.5%) and specificities (99.7%–99.8% vs. 99.5%–99.8%) of focal lesion detectability (p > 0.050) and similar diagnostic accuracy (FOM, 0.958 vs. 0.957, p = 0.583) compared to those of the conventional DWI. Conclusion: MB-VERSE DWI exhibited a significantly shorter acquisition time than conventional DWI, with compromised overall IQ and lower SNR but preserved CNR and focal liver lesion detectability. MB-VERSE DWI may be a useful alternative for patients requiring a short acquisition time.
참고문헌 (31)
- Taouli B, "Diffusion-weighted MR imaging of the liver", Radiology, 254, pp.47~66 (2010)
- Bae H, "Effectiveness of hepatocellular carcinoma surveillance and an optimal surveillance interval : nationwide cohort of Korea", Yonsei Med J, 62, pp.758~766 (2021)
- Lee JS, "Prognostic value of alpha-fetoprotein in patients who achieve a complete response to transarterial chemoembolization for hepatocellular carcinoma", Yonsei Med J, 62, pp.12~20 (2021)
- Hargreaves BA, "Variable-rate selective excitation for rapid MRI sequences", Magn Reson Med, 52, pp.590~597 (2004)
- Barth M, "Simultaneous multislice(SMS)imaging techniques", Magn Reson Med, 75, pp.63~81 (2016)
- Yoon JH, "Rapid imaging : recent advances in abdominal MRI for reducing acquisition time and its clinical applications", Korean J Radiol, 20, pp.1597~1615 (2019)
- Feinberg DA, "Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging", PLoS One, 5, pp.e15710~ (2010)
- Lau AZ, "Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging", Magn Reson Med, 73, pp.995~1004 (2015)
- Morita K, "Multiband-SENSE EPI with variable-rate selective excitation (VERSE) pulses for accelerating abdominal DWI with respiratory triggering", 2021 International Society for Magnetic Resonance in Medicine (ISMRM) &Society for MR Radiographers & Technologists (SMRT) Annual Meeting & Exhibition (2021), ISMRM
- Lee D, "Time-optimal design for multidimensional and parallel transmit variable-rate selective excitation", Magn Reson Med, 61, pp.1471~1479 (2009)
- Conolly S, "Variable-rate selective excitation", J Magn Reson, 78, pp.440~458 (1988)
- Busse R, "Improved slice profile and reduced fast spin echo spacing with variable-rate selective excitation", 11th Annual Meeting of International Society for Magnetic Resonance in Medicine (ISMRM) (2003), ISMRM
- Zur Y, "Clinical 3T SAR reduction using VERSE pulses", The 11th Annual Meeting of International Society for Magnetic Resonance in Medicine (ISMRM) (2003), ISMRM
- Hirokawa Y, "Hepatic lesions : improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique--evaluation of SPIO-enhanced T2-weighted MR images", Radiology, 251, pp.388~397 (2009)
- Boss A, "Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas : optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis", Eur J Radiol, 85, pp.1948~1955 (2016)
- Zhuo J, "AAPM", RSNA physics tutorial for residents : MR artifacts, safety, and quality control, 2006, pp.26, 275~297
- American College of Radiology, "Liver imaging reporting and data system version 2018" (2018), American College of Radiology
- Yoon JK, "Compressed sensing and parallel imaging for double hepatic arterial phase acquisition in gadoxetate-enhanced dynamic liver magnetic resonance imaging", Invest Radiol, 54, pp.374~382 (2019)
- Kim YY, "Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver", Eur J Radiol, 132, pp.109292~ (2020)
- Chakraborty DP, "Recent advances in observer performance methodology : jackknife free-response ROC(JAFROC)", Radiat Prot Dosimetry, 114, pp.26~31 (2005)
- Zheng B, "A comparison of two data analyses from two observer performance studies using jackknife ROC and JAFROC", Med Phys, 32, pp.1031~1034 (2005)
- Mandrekar JN, "Measures of interrater agreement", J Thorac Oncol, 6, pp.6~7 (2011)
- Landis JR, "The measurement of observer agreement for categorical data", Biometrics, 33, pp.159~174 (1977)
- Obele CC, "Simultaneous multislice accelerated free-breathing diffusion-weighted imaging of the liver at 3T", Abdom Imaging, 40, pp.2323~2330 (2015)
- Ciritsis A, "Accelerated diffusion-weighted imaging for lymph node assessment in the pelvis applying simultaneous multislice acquisition : a healthy volunteer study", Medicine(Baltimore), 97, pp.e11745~ (2018)
- Taron J, "Simultaneous multislice diffusion-weighted MRI of the liver : analysis of different breathing schemes in comparison to standard sequences", J Magn Reson Imaging, 44, pp.865~879 (2016)
- Jang W, "Intra-individual comparison of conventional and simultaneous multislice-accelerated diffusion-weighted imaging in upper abdominal solid organs:value of ADC normalization using the spleen as a reference organ", Abdom Radiol(NY), 44, pp.1808~1815 (2019)
- Dietrich O, "Noise correction for the exact determination of apparent diffusion coefficients at low SNR", Magn Reson Med, 45, pp.448~453 (2001)
- Ohno N, "Diffusion-weighted imaging of the abdomen during a single breath-hold using simultaneousmultislice echo-planar imaging", Magn Reson Med Sci, 22, pp.253~262 (2023)
- Taron J, "Scan time minimization in hepatic diffusion-weighted imaging : evaluation of the simultaneous multislice acceleration technique with different acceleration factors and gradient preparation schemes", MAGMA, 29, pp.739~749 (2016)
- Taron J, "Scan time reduction in diffusion-weighted imaging of the pancreas using a simultaneous multislice technique with different acceleration factors : how fast can we go?", Eur Radiol, 28, pp.1504~1511 (2018)