Guidelines for Cardiovascular Magnetic Resonance Imaging from the Korean Society of Cardiovascular Imaging (KOSCI) - Part 2: Interpretation of Cine, Flow, and Angiography Data
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Cardiovascular magnetic resonance imaging (CMR) is expected to be increasingly used in Korea due to technology advances and the expanded national insurance coverage of these tests. For improved patient care, it is crucial not only that CMR images are properly acquired but that they are accurately interpreted by welltrained personnel. In response to the increased demand for CMR, the Korean Society of Cardiovascular Imaging (KOSCI) has issued interpretation guidelines in conjunction with the Korean Society of Radiology (KSR). KOSCI has also created a formal Committee on CMR Guidelines to write updated practices. The members of this Committee review previously published interpretation guidelines and discuss the patterns of CMR use in Korea.
Abstract
Cardiovascular magnetic resonance imaging (CMR) is expected to be increasingly used in Korea due to technology advances and the expanded national insurance coverage of these tests. For improved patient care, it is crucial not only that CMR images are properly acquired but that they are accurately interpreted by welltrained personnel. In response to the increased demand for CMR, the Korean Society of Cardiovascular Imaging (KOSCI) has issued interpretation guidelines in conjunction with the Korean Society of Radiology (KSR). KOSCI has also created a formal Committee on CMR Guidelines to write updated practices. The members of this Committee review previously published interpretation guidelines and discuss the patterns of CMR use in Korea.
참고문헌 (37)
- 윤연이, "2014 Korean Guidelines for Appropriate Utilization of Cardiovascular Magnetic Resonance Imaging: A Joint Report of the Korean Society of Cardiology and the Korean Society of Radiology", Korean Journal of Radiology, 15(6), pp.659~688 (2014), 대한영상의학회[DOI]
- 김영진, "Korean Guidelines for the Appropriate Use of Cardiac CT", Korean Journal of Radiology, 16(2), pp.251~285 (2015), 대한영상의학회[DOI]
- ASCI Practice Guideline Working Group, "2017 Multimodality Appropriate Use Criteria for Noninvasive Cardiac Imaging: Expert Consensus of the Asian Society of Cardiovascular Imaging", Korean Journal of Radiology, 18(6), pp.871~880 (2017), 대한영상의학회[DOI]
- 구현우, "Comparison between Three-Dimensional Navigator-Gated Whole-Heart MRI and Two-Dimensional Cine MRI in Quantifying Ventricular Volumes", Korean Journal of Radiology, 19(4), pp.704~714 (2018), 대한영상의학회[DOI]
- Chen Cui, "Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI", Korean Journal of Radiology, 20(1), pp.114~125 (2019), 대한영상의학회[DOI]
- Hyun Woo Goo, "Semiautomatic Three-Dimensional Threshold-Based Cardiac Computed Tomography Ventricular Volumetry in Repaired Tetralogy of Fallot: Comparison with Cardiac Magnetic Resonance Imaging", Korean Journal of Radiology, 20(1), pp.102~113 (2019), 대한영상의학회[DOI]
- 이지원, "Predictive Value of Cardiac Magnetic Resonance Imaging-Derived Myocardial Strain for Poor Outcomes in Patients with Acute Myocarditis", Korean Journal of Radiology, 18(4), pp.643~654 (2017), 대한영상의학회[DOI]
- Pizzino F, "Re:multi-parameter CMR approach in acute myocarditis to improve diagnosis and prognostic stratification", Korean J Radiol, 19, pp.366~367 (2018)
- 이희곤, "Use of Cardiac Computed Tomography and Magnetic Resonance Imaging in Case Management of Atrial Fibrillation with Catheter Ablation", Korean Journal of Radiology, 20(5), pp.695~708 (2019), 대한영상의학회[DOI]
- 민지영, "Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease", Korean Journal of Radiology, 19(6), pp.1007~1020 (2018), 대한영상의학회[DOI]
- 임지연, "Single-Dose Gadoterate Meglumine for 3T Late Gadolinium Enhancement MRI for the Assessment of Chronic Myocardial Infarction: Intra-Individual Comparison with Conventional Double-Dose 1.5T MRI", Korean Journal of Radiology, 19(3), pp.372~380 (2018), 대한영상의학회[DOI]
- Lei Wang, "Self-Gated Late Gadolinium Enhancement at 7T to Image Rats with Reperfused Acute Myocardial Infarction", Korean Journal of Radiology, 19(2), pp.247~255 (2018), 대한영상의학회[DOI]
- Yinyin Chen, "Role of Myocardial Extracellular Volume Fraction Measured with Magnetic Resonance Imaging in the Prediction of Left Ventricular Functional Outcome after Revascularization of Chronic Total Occlusion of Coronary Arteries", Korean Journal of Radiology, 20(1), pp.83~93 (2019), 대한영상의학회[DOI]
- Karimi S, "Re: prediction of the left ventricular functional outcome by myocardial extracellular volume fraction measured using magnetic resonance imaging: methodological issue", Korean J Radiol, 20, pp.1001~1002 (2019)
- Cerqueira MD, "Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association", Circulation, 105, pp.539~542 (2002)
- Hundley WG, "Society for Cardiovascular Magnetic Resonance guidelines for reporting cardiovascular magnetic resonance examinations", J Cardiovasc Magn Reson, 11, pp.5~ (2009)
- Schulz-Menger J, "Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) board of trustees task force on standardized post processing", J Cardiovasc Magn Reson, 15, pp.35~ (2013)
- Maceira AM, "Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance", J Cardiovasc Magn Reson, 8, pp.417~426 (2006)
- Hudsmith LE, "Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging", J Cardiovasc Magn Reson, 7, pp.775~782 (2005)
- Hamdan A, "Improved quantitative assessment of left ventricular volumes using TGrE approach after application of extracellular contrast agent at 3 Tesla", J Cardiovasc Magn Reson, 9, pp.845~853 (2007)
- Thiele H, "Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession", J Cardiovasc Magn Reson, 4, pp.327~339 (2002)
- Puntmann VO, "Left ventricular chamber dimensions and wall thickness by cardiovascular magnetic resonance: comparison with transthoracic echocardiography", Eur Heart J Cardiovasc Imaging, 14, pp.240~246 (2013)
- Alfakih K, "Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences", J Magn Reson Imaging, 17, pp.323~329 (2003)
- Alfakih K, "Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging", J Magn Reson Imaging, 18, pp.25~32 (2003)
- Clarke CJ, "Assessment of the accuracy and reproducibility of RV volume measurements by CMR in congenital heart disease", JACC Cardiovasc Imaging, 5, pp.28~37 (2012)
- Mohiaddin RH, "Magnetic resonance volume flow and jet velocity mapping in aortic coarctation", J Am Coll Cardiol, 22, pp.1515~1521 (1993)
- Mohiaddin RH, "MR blood flow measurement. Clinical application in the heart and circulation", Cardiol Clin, 16, pp.161~187 (1998)
- Rebergen SA, "Magnetic resonance measurement of velocity and flow:technique, validation, and cardiovascular applications", Am Heart J, 126, pp.1439~1456 (1993)
- O'Brien KR, "MRI phase contrast velocity and flow errors in turbulent stenotic jets", J Magn Reson Imaging, 28, pp.210~218 (2008)
- Holland BJ, "Baseline correction of phase-contrast images in congenital cardiovascular magnetic resonance", J Cardiovasc Magn Reson, 12, pp.11~ (2010)
- Chernobelsky A, "Baseline correction of phase contrast images improves quantification of blood flow in the great vessels", J Cardiovasc Magn Reson, 9, pp.681~685 (2007)
- Holloway BJ, "Imaging of thoracic aortic disease", Br J Radiol, 84(Spec No 3), pp.S338~S354 (2011)
- Hiratzka LF, "2010 ACCF", AHA, ACR, pp.ASA, SCA[DOI]
- Glockner JF, "MR angiography interpretation: techniques and pitfalls", Magn Reson Imaging Clin N Am, 13, pp.23~40 (2005)
- Kalb B, "MR imaging of pulmonary embolism: diagnostic accuracy of contrast-enhanced 3D MR pulmonary angiography, contrast-enhanced lowflip angle 3D GRE, and nonenhanced free-induction FISP sequences", Radiology, 263, pp.271~278 (2012)
- Grosse-Wortmann L, "Anatomical and functional evaluation of pulmonary veins in children by magnetic resonance imaging", J Am Coll Cardiol, 49, pp.993~1002 (2007)
- Sakuma H, "Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography", J Am Coll Cardiol, 48, pp.1946~1950 (2006)
