Guidelines for Cardiovascular Magnetic Resonance Imaging from the Korean Society of Cardiovascular Imaging (KOSCI) - Part 3: Perfusion, Delayed Enhancement, and T1- and T2 Mappin
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This document is the third part of the guidelines for the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by a Consensus Committee of the Korean Society of Cardiovascular Imaging (KOSCI) to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment, consisting of “What-to-See,” “How-To,” and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.
Abstract
This document is the third part of the guidelines for the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by a Consensus Committee of the Korean Society of Cardiovascular Imaging (KOSCI) to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment, consisting of “What-to-See,” “How-To,” and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.
참고문헌 (58)
- Coelho-Filho OR, "MR myocardial perfusion imaging", Radiology, 266, pp.701~715 (2013)
- Schulz-Menger J, "Standardized image interpretation and post processing in cardiovascular magnetic resonance : Society for Cardiovascular Magnetic Resonance(SCMR)board of trustees task force on standardized post processing", J Cardiovasc Magn Reson, 15, pp.35~ (2013)
- 민지영, "Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease", Korean Journal of Radiology, 19(6), pp.1007~1020 (2018), 대한영상의학회[DOI]
- Chung SY, "Comparison of stress perfusion MRI and SPECT for detection of myocardial ischemia in patients with angiographically proven threevessel coronary artery disease", AJR Am J Roentgenol, 195, pp.356~362 (2010)
- Panting JR, "Abnormal subendocardial perfusion in cardiac syndrome X detected by cardiovascular magnetic resonance imaging", N Engl J Med, 346, pp.1948~1953 (2002)
- Maron BJ, "Intramural("small vessel")coronary artery disease in hypertrophic cardiomyopathy", J Am Coll Cardiol, 8, pp.545~557 (1986)
- Maron MS, "The case for myocardial ischemia in hypertrophic cardiomyopathy", J Am Coll Cardiol, 54, pp.866~875 (2009)
- 김여군, "Non-Ischemic Perfusion Defects due to Delayed Arrival of Contrast Material on Stress Perfusion Cardiac Magnetic Resonance Imaging after Coronary Artery Bypass Graft Surgery", Korean Journal of Radiology, 15(2), pp.188~194 (2014), 대한영상의학회[DOI]
- Tejani FH, "Effect of caffeine on SPECT myocardial perfusion imaging during regadenoson pharmacologic stress: a prospective, randomized, multicenter study", Int J Cardiovasc Imaging, 30, pp.979~989 (2014)
- Kovacs D, "Effect of caffeine on myocardial perfusion imaging using single photon emission computed tomography during adenosine pharmacologic stress", Am J Ther, 15, pp.431~434 (2008)
- Jerosch-Herold M, "Quantification of myocardial perfusion by cardiovascular magnetic resonance", J Cardiovasc Magn Reson, 12, pp.57~ (2010)
- Schwitter J, "Magnetic resonance-based assessment of global coronary flow and flow reserve and its relation to left ventricular functional parameters : a comparison with positron emission tomography", Circulation, 101, pp.2696~2702 (2000)
- Kelle S, "Evaluation of contrast wash-in and peak enhancement in adenosine first pass perfusion CMR in patients post bypass surgery", J Cardiovasc Magn Reson, 12, pp.28~ (2010)
- Keelan PC, "Long-term prognostic value of coronary calcification detected by electron-beam computed tomography in patients undergoing coronary angiography", Circulation, 104, pp.412~417 (2001)
- Rieber J, "Cardiac magnetic resonance perfusion imaging for the functional assessment of coronary artery disease : a comparison with coronary angiography and fractional flow reserve", Eur Heart J, 27, pp.1465~1471 (2006)
- Kroll K, "Modeling regional myocardial flows from residue functions of an intravascular indicator", Am J Physiol, 271, pp.H1643~H1655 (1996)
- Jerosch-Herold M, "Myocardial blood flow quantification with MRI by model-independent deconvolution", Med Phys, 29, pp.886~897 (2002)
- Ishida M, "Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance", J Cardiovasc Magn Reson, 13, pp.28~ (2011)
- Christian TF, "Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique : comparison to single-bolus injection method", J Magn Reson Imaging, 27, pp.1271~1277 (2008)
- Gatehouse PD, "Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance", J Magn Reson Imaging, 20, pp.39~45 (2004)
- Jerosch-Herold M, "Direct comparison of an intravascular and an extracellular contrast agent for quantification of myocardial perfusion. Cardiac MRI Group", Int J Card Imaging, 15, pp.453~464 (1999)
- Kim RJ, "How we perform delayed enhancement imaging", J Cardiovasc Magn Reson, 5, pp.505~514 (2003)
- Mahrholdt H, "Delayed enhancement cardiovascular magnetic resonance assessment of non-ischaemic cardiomyopathies", Eur Heart J, 26, pp.1461~1474 (2005)
- 이지원, "Predictive Value of Cardiac Magnetic Resonance Imaging-Derived Myocardial Strain for Poor Outcomes in Patients with Acute Myocarditis", Korean Journal of Radiology, 18(4), pp.643~654 (2017), 대한영상의학회[DOI]
- Kim RJ, "The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction", N Engl J Med, 343, pp.1445~1453 (2000)
- Klem I, "Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging", J Am Coll Cardiol, 47, pp.1630~1638 (2006)
- Abbas A, "Cardiac MR assessment of microvascular obstruction", Br J Radiol, 88, pp.20140470~ (2015)
- Rajiah P, "MR imaging of myocardial infarction", Radiographics, 33, pp.1383~1412 (2013)
- Saremi F, "Optimizing cardiac MR imaging : practical remedies for artifacts", Radiographics, 28, pp.1161~1187 (2008)
- Kellman P, "Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement", Magn Reson Med, 47, pp.372~383 (2002)
- Kellman P, "Cardiac imaging techniques for physicians : late enhancement", J Magn Reson Imaging, 36, pp.529~542 (2012)
- Farrelly C, "Improved detection of subendocardial hyperenhancement in myocardial infarction using dark blood-pool delayed enhancement MRI", AJR Am J Roentgenol, 196, pp.339~348 (2011)
- Bondarenko O, "Standardizing the definition of hyperenhancement in the quantitative assessment of infarct size and myocardial viability using delayed contrast-enhanced CMR", J Cardiovasc Magn Reson, 7, pp.481~485 (2005)
- 임지연, "Single-Dose Gadoterate Meglumine for 3T Late Gadolinium Enhancement MRI for the Assessment of Chronic Myocardial Infarction: Intra-Individual Comparison with Conventional Double-Dose 1.5T MRI", Korean Journal of Radiology, 19(3), pp.372~380 (2018), 대한영상의학회[DOI]
- Amado LC, "Accurate and objective infarct sizing by contrast-enhanced magnetic resonance imaging in a canine myocardial infarction model", J Am Coll Cardiol, 44, pp.2383~2389 (2004)
- Flett AS, "Evaluation of techniques for the quantification of myocardial scar of differing etiology using cardiac magnetic resonance", JACC Cardiovasc Imaging, 4, pp.150~156 (2011)
- Aljaroudi WA, "Role of CMR imaging in risk stratification for sudden cardiac death", JACC Cardiovasc Imaging, 6, pp.392~406 (2013)
- Moon JC, "Myocardial T1mapping and extracellular volume quantification : a Society for Cardiovascular Magnetic Resonance(SCMR)and CMR Working Group of the European Society of Cardiology consensus statement", J Cardiovasc Magn Reson, 15, pp.92~ (2013)
- Ugander M, "Myocardial edema as detected by pre-contrast T1 and T2 CMR delineates area at risk associated with acute myocardial infarction", JACC Cardiovasc Imaging, 5, pp.596~603 (2012)
- Karamitsos TD, "Noncontrast T1 mapping for the diagnosis of cardiac amyloidosis", JACC Cardiovasc Imaging, 6, pp.488~497 (2013)
- Sado DM, "Identification and assessment of Anderson-Fabry disease by cardiovascular magnetic resonance noncontrast myocardial T1 mapping", Circ Cardiovasc Imaging, 6, pp.392~398 (2013)
- Pedersen SF, "Assessment of intramyocardial hemorrhage by T1-weighted cardiovascular magnetic resonance in reperfused acute myocardial infarction", J Cardiovasc Magn Reson, 14, pp.59~ (2012)
- Messroghli DR, "Modified Look-Locker inversion recovery(MOLLI)for high-resolution T1 mapping of the heart", Magn Reson Med, 52, pp.141~146 (2004)
- Arheden H, "Measurement of the distribution volume of gadopentetate dimeglumine at echo-planar MR imaging to quantify myocardial infarction : comparison with 99mTc-DTPA autoradiography in rats", Radiology, 211, pp.698~708 (1999)
- Taylor AJ, "T1 mapping : basic techniques and clinical applications", JACC Cardiovasc Imaging, 9, pp.67~81 (2016)
- Kellman P, "Extracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method", J Cardiovasc Magn Reson, 14, pp.63~ (2012)
- Miller CA, "Comprehensive validation of cardiovascular magnetic resonance techniques for the assessment of myocardial extracellular volume", Circ Cardiovasc Imaging, 6, pp.373~383 (2013)
- Yinyin Chen, "Role of Myocardial Extracellular Volume Fraction Measured with Magnetic Resonance Imaging in the Prediction of Left Ventricular Functional Outcome after Revascularization of Chronic Total Occlusion of Coronary Arteries", Korean Journal of Radiology, 20(1), pp.83~93 (2019), 대한영상의학회[DOI]
- 이희곤, "Use of Cardiac Computed Tomography and Magnetic Resonance Imaging in Case Management of Atrial Fibrillation with Catheter Ablation", Korean Journal of Radiology, 20(5), pp.695~708 (2019), 대한영상의학회[DOI]
- Treibel TA, "Automatic measurement of the myocardial interstitium : synthetic extracellular volume quantification without hematocrit sampling", JACC Cardiovasc Imaging, 9, pp.54~63 (2016)
- Shang Y, "Extracellular volume fraction measurements derived from the longitudinal relaxation of blood-based synthetic hematocrit may lead to clinical errors in 3 T cardiovascular magnetic resonance", J Cardiovasc Magn Reson, 20, pp.56~ (2018)
- Kammerlander AA, "Extracellular volume quantification by cardiac magnetic resonance imaging without hematocrit sampling: ready for prime time?", Wien Klin Wochenschr, 130, pp.190~196 (2018)
- Robson MD, "T1measurements in the human myocardium : the effects of magnetization transfer on the SASHA and MOLLI sequences", Magn Reson Med, 70, pp.664~670 (2013)
- Friedrich MG, "Cardiovascular magnetic resonance in myocarditis : a JACC white paper", J Am Coll Cardiol, 53, pp.1475~1487 (2009)
- He T, "Myocardial T2* measurements in ironoverloaded thalassemia : an in vivo study to investigate optimal methods of quantification", Magn Reson Med, 60, pp.1082~1089 (2008)
- Anderson LJ, "Cardiovascular T2-star(T2*)magnetic resonance for the early diagnosis of myocardial iron overload", Eur Heart J, 22, pp.2171~2179 (2001)
- Carpenter JP, "On T2* magnetic resonance and cardiac iron", Circulation, 123, pp.1519~1528 (2011)
- Kirk P, "Cardiac T2* magnetic resonance for prediction of cardiac complications in thalassemia major", Circulation, 120, pp.1961~1968 (2009)
