Guidelines for Cardiovascular Magnetic Resonance Imaging from Korean Society of Cardiovascular Imaging (KOSCI) - Part 1: Standardized Protocol
4
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/ symptom-based protocols based on a survey of cardiologists and various appropriateuse criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patientbased approach to clinical CMR and contribute to the promotion of public health.
Abstract
Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/ symptom-based protocols based on a survey of cardiologists and various appropriateuse criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patientbased approach to clinical CMR and contribute to the promotion of public health.
참고문헌 (62)
- 윤연이, "2014 Korean Guidelines for Appropriate Utilization of Cardiovascular Magnetic Resonance Imaging: A Joint Report of the Korean Society of Cardiology and the Korean Society of Radiology", Korean Journal of Radiology, 15(6), pp.659~688 (2014), 대한영상의학회[DOI]
- Chan CW, "ASCI 2010 standardized practice protocol for cardiac magnetic resonance imaging: a report of the Asian society of cardiovascular imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group", Int J Cardiovasc Imaging, 26, pp.187~202 (2010)
- Kramer CM, "Standardized cardiovascular magnetic resonance (CMR) protocols 2013update", J Cardiovasc Magn Reson, 15, pp.91~ (2013)
- Woodard PK, "ACR practice guideline for the performance and interpretation of cardiac magnetic resonance imaging (MRI)", J Am Coll Radiol, 3, pp.665~676 (2006)
- Kramer CM, "Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols", J Cardiovasc Magn Reson, 10, pp.35~ (2008)
- Fratz S, "Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease", J Cardiovasc Magn Reson, 15, pp.51~ (2013)
- ASCI Practice Guideline Working Group, "2017 Multimodality Appropriate Use Criteria for Noninvasive Cardiac Imaging: Expert Consensus of the Asian Society of Cardiovascular Imaging", Korean Journal of Radiology, 18(6), pp.871~880 (2017), 대한영상의학회[DOI]
- Friedrich MG, "Canadian Society for Cardiovascular Magnetic Resonance (CanSCMR)recommendations for cardiovascular magnetic resonance image analysis and reporting", Can J Cardiol, 29, pp.260~265 (2013)
- Hundley WG, "Society for Cardiovascular Magnetic Resonance guidelines for reporting cardiovascular magnetic resonance examinations", J Cardiovasc Magn Reson, 11, pp.5~ (2009)
- Levine GN, "Safety of magnetic resonance imaging in patients with cardiovascular devices:an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention:endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance", Circulation, 116, pp.2878~2891 (2007)
- Ridgway JP, "Cardiovascular magnetic resonance physics for clinicians: part I", J Cardiovasc Magn Reson, 12, pp.71~ (2010)
- Biglands JD, "Cardiovascular magnetic resonance physics for clinicians: Part II", J Cardiovasc Magn Reson, 14, pp.66~ (2012)
- Ferreira PF, "Cardiovascular magnetic resonance artefacts", J Cardiovasc Magn Reson, 15, pp.41~ (2013)
- Huang SY, "Body MR imaging: artifacts, k-Space, and solutions", Radiographics, 35, pp.1439~1460 (2015)
- Saloner D, "MR physics in practice: how to optimize acquisition quality and time for cardiac MR imaging", Magn Reson Imaging Clin N Am, 23, pp.1~6 (2015)
- Ibrahim el-SH, "Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges", Int J Cardiovasc Imaging, 28, pp.2027~2047 (2012)
- Sena L, "Cardiac MR imaging: from physics to protocols", Pediatr Radiol, 38(Suppl 2), pp.S185~S191 (2008)
- Ginat DT, "Cardiac imaging: part 1, MR pulse sequences, imaging planes, and basic anatomy", AJR Am J Roentgenol, 197, pp.808~815 (2011)
- Nael K, "Cardiac MR imaging:new advances and role of 3T", Magn Reson Imaging Clin N Am, 15, pp.291~300 (2007)
- Gimbel JR, "Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla", Pacing Clin Electrophysiol, 31, pp.795~801 (2008)
- Rajiah P, "Cardiovascular MR imaging at 3 T:opportunities, challenges, and solutions", Radiographics, 34, pp.1612~1635 (2014)
- Mangion K, "Myocardial strain in healthy adults across a broad age range as revealed by cardiac magnetic resonance imaging at 1.5 and 3.0T:Associations of myocardial strain with myocardial region, age, and sex", J Magn Reson Imaging, 44, pp.1197~1205 (2016)
- Oshinski JN, "Cardiovascular magnetic resonance at 3.0 T: current state of the art", J Cardiovasc Magn Reson, 12, pp.55~ (2010)
- 임지연, "Single-Dose Gadoterate Meglumine for 3T Late Gadolinium Enhancement MRI for the Assessment of Chronic Myocardial Infarction: Intra-Individual Comparison with Conventional Double-Dose 1.5T MRI", Korean Journal of Radiology, 19(3), pp.372~380 (2018), 대한영상의학회[DOI]
- 민지영, "Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease", Korean Journal of Radiology, 19(6), pp.1007~1020 (2018), 대한영상의학회[DOI]
- Roguin A, "Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices", Europace, 10, pp.336~346 (2008)
- Sierra M, "Magnetic resonance imaging in patients with implantable cardiac devices", Rev Cardiovasc Med, 9, pp.232~238 (2008)
- Burke PT, "A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI)", J Interv Card Electrophysiol, 28, pp.59~66 (2010)
- Halshtok O, "Pacemakers and magnetic resonance imaging:no longer an absolute contraindication when scanned correctly", Isr Med Assoc J, 12, pp.391~395 (2010)
- Cronin EM, "Magnetic resonance imaging conditional pacemakers: rationale, development and future directions", Indian Pacing Electrophysiol J, 12, pp.204~212 (2012)
- Miller JD, "Implantable electronic cardiac devices and compatibility with magnetic resonance imaging", J Am Coll Cardiol, 68, pp.1590~1598 (2016)
- Shulman RM, "Cardiac implanted electronic devices and MRI safety in 2018-the state of play", Eur Radiol, 28, pp.4062~4065 (2018)
- Hsu C, "Implantable devices and magnetic resonance imaging", Heart Lung Circ, 21, pp.358~363 (2012)
- Strach K, "Cardiac stress MR imaging with dobutamine", Eur Radiol, 16, pp.2728~2738 (2006)
- Ordovas KG, "Delayed contrast enhancement on MR images of myocardium: past, present, future", Radiology, 261, pp.358~374 (2011)
- 김판기, "Myocardial T1 and T2 Mapping: Techniques and Clinical Applications", Korean Journal of Radiology, 18(1), pp.113~131 (2017), 대한영상의학회[DOI]
- Hamdy A, "Cardiac MR assessment of coronary arteries", Cardiovasc Imaging Asia, 1, pp.49~59
- Montant P, "MR imaging assessment of myocardial edema with T2 mapping", Diagn Interv Imaging, 96, pp.885~890 (2015)
- Kim HW, "Relationship of T2-weighted MRI myocardial hyperintensity and the ischemic area-at-risk", Circ Res, 117, pp.254~265 (2015)
- Srichai MB, "Cardiovascular applications of phase-contrast MRI", AJR Am J Roentgenol, 192, pp.662~675 (2009)
- Lotz J, "Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation", Radiographics, 22, pp.651~671 (2002)
- Verhaert D, "Direct T2quantification of myocardial edema in acute ischemic injury", JACC Cardiovasc Imaging, 4, pp.269~278 (2011)
- 구현우, "Comparison between Three-Dimensional Navigator-Gated Whole-Heart MRI and Two-Dimensional Cine MRI in Quantifying Ventricular Volumes", Korean Journal of Radiology, 19(4), pp.704~714 (2018), 대한영상의학회[DOI]
- Lei Wang, "Self-Gated Late Gadolinium Enhancement at 7T to Image Rats with Reperfused Acute Myocardial Infarction", Korean Journal of Radiology, 19(2), pp.247~255 (2018), 대한영상의학회[DOI]
- Karimi S, "Re: prediction of the left ventricular functional outcome by myocardial extracellular volume fraction measured using magnetic resonance imaging: methodological issue", Korean J Radiol, 20, pp.1001~1002 (2019)
- Chen Cui, "Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI", Korean Journal of Radiology, 20(1), pp.114~125 (2019), 대한영상의학회[DOI]
- Sakuma H, "Magnetic resonance imaging for ischemic heart disease", J Magn Reson Imaging, 26, pp.3~13 (2007)
- Childs H, "Cardiovascular magnetic resonance imaging in myocarditis", Prog Cardiovasc Dis, 54, pp.266~275 (2011)
- Florian A, "Cardiac magnetic resonance imaging in ischemic heart disease: a clinical review", J Med Life, 4, pp.330~345 (2011)
- Nikolaou K, "MRI and CT in the diagnosis of coronary artery disease:indications and applications", Insights Imaging, 2, pp.9~24 (2011)
- Francone M, "Role of cardiac magnetic resonance in the evaluation of dilated cardiomyopathy: diagnostic contribution and prognostic significance", ISRN Radiol, 2014, pp.365404~ (2014)
- Tavano A, "MR imaging of arrhythmogenic right ventricular dysplasia: what the radiologist needs to know", Diagn Interv Imaging, 96, pp.449~460 (2015)
- von Knobelsdorff-Brenkenhoff F, "Role of cardiovascular magnetic resonance in the guidelines of the European Society of Cardiology", J Cardiovasc Magn Reson, 18, pp.6~ (2016)
- Pizzino F, "Re:multi-parameter CMR approach in acute myocarditis to improve diagnosis and prognostic stratification", Korean J Radiol, 19, pp.366~367 (2018)
- Yinyin Chen, "Role of Myocardial Extracellular Volume Fraction Measured with Magnetic Resonance Imaging in the Prediction of Left Ventricular Functional Outcome after Revascularization of Chronic Total Occlusion of Coronary Arteries", Korean Journal of Radiology, 20(1), pp.83~93 (2019), 대한영상의학회[DOI]
- 이희곤, "Use of Cardiac Computed Tomography and Magnetic Resonance Imaging in Case Management of Atrial Fibrillation with Catheter Ablation", Korean Journal of Radiology, 20(5), pp.695~708 (2019), 대한영상의학회[DOI]
- 이지원, "Predictive Value of Cardiac Magnetic Resonance Imaging-Derived Myocardial Strain for Poor Outcomes in Patients with Acute Myocarditis", Korean Journal of Radiology, 18(4), pp.643~654 (2017), 대한영상의학회[DOI]
- 안형우, "Multimodality Imaging in Patients with Secondary Hypertension: With a Focus on Appropriate Imaging Approaches Depending on the Etiologies", Korean Journal of Radiology, 19(2), pp.272~283 (2018), 대한영상의학회[DOI]
- Patel AR, "Role of cardiac magnetic resonance in the diagnosis and prognosis of nonischemic cardiomyopathy", JACC Cardiovasc Imaging, 10, pp.1180~1193 (2017)
- Peterzan MA, "The role of cardiovascular magnetic resonance imaging in heart failure", Card Fail Rev, 2, pp.115~122 (2016)
- 김영진, "Korean Guidelines for the Appropriate Use of Cardiac CT", Korean Journal of Radiology, 16(2), pp.251~285 (2015), 대한영상의학회[DOI]
- Saremi F, "Optimizing cardiac MR imaging: practical remedies for artifacts", Radiographics, 28, pp.1161~1187 (2008)