초록
Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard noninvasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for realtime cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.
Abstract
Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard noninvasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for realtime cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.
참고문헌 (97)
- Lee DC, "The growth and evolution of cardiovascular magnetic resonance : a 20-year history of the Society for Cardiovascular Magnetic Resonance(SCMR)annual scientific sessions", J Cardiovasc Magn Reson, 20, pp.8~ (2018)
- Lanzer P, "Cardiac imaging using gated magnetic resonance", Radiology, 150, pp.121~127 (1984)
- Frahm J, "Real-time magnetic resonance imaging : radial gradient-echo sequences with nonlinear inverse reconstruction", Invest Radiol, 54, pp.757~766 (2019)
- Nayak KS, "Realtime magnetic resonance imaging", J Magn Reson Imaging (2020)
- Dietz B, "Nomenclature for realtime magnetic resonance imaging", Magn Reson Med, 81, pp.1483~1484 (2019)
- Sodickson DK, "Simultaneous acquisition of spatial harmonics(SMASH) : fast imaging with radiofrequency coil arrays", Magn Reson Med, 38, pp.591~603 (1997)
- Pruessmann KP, "SENSE : sensitivity encoding for fast MRI", Magn Reson Med, 42, pp.952~962 (1999)
- Griswold MA, "Generalized autocalibrating partially parallel acquisitions(GRAPPA)", Magn Reson Med, 47, pp.1202~1210 (2002)
- Pruessmann KP, "Sensitivity encoded cardiac MRI", J Cardiovasc Magn Reson, 3, pp.1~9 (2001)
- Kellman P, "Adaptive sensitivity encoding incorporating temporal filtering(TSENSE)", Magn Reson Med, 45, pp.846~852 (2001)
- Breuer FA, "Dynamic autocalibrated parallel imaging using temporal GRAPPA(TGRAPPA)", Magn Reson Med, 53, pp.981~985 (2005)
- Madore B, "Unaliasing by fourierencoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI", Magn Reson Med, 42, pp.813~828 (1999)
- Tsao J, "k-t BLAST and k-t SENSE : dynamic MRI with high frame rate exploiting spatiotemporal correlations", Magn Reson Med, 50, pp.1031~1042 (2003)
- Pedersen H, "k-t PCA : temporally constrained k-t BLAST reconstruction using principal component analysis", Magn Reson Med, 62, pp.706~716 (2009)
- Brummer ME, "Noquist : reduced field-of-view imaging by direct Fourier inversion", Magn Reson Med, 51, pp.331~342 (2004)
- Malik SJ, "x-f Choice : reconstruction of undersampled dynamic MRI by data-driven alias rejection applied to contrast-enhanced angiography", Magn Reson Med, 56, pp.811~823 (2006)
- Huang F, "k-t GRAPPA : a k-space implementation for dynamic MRI with high reduction factor", Magn Reson Med, 54, pp.1172~1184 (2005)
- Tsao J, "MRI temporal acceleration techniques", J Magn Reson Imaging, 36, pp.543~560 (2012)
- Lauterbur PC, "Image formation by induced local interactions : examples employing nuclear magnetic resonance", Nature, 242, pp.190~191 (1973)
- Ahn CB, "High-speed spiral-scan echo planar NMR imaging-I", IEEE Trans Med Imaging, 5, pp.2~7 (1986)
- Uecker M, "ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI : where SENSE meets GRAPPA", Magn Reson Med, 71, pp.990~1001 (2014)
- Seiberlich N, "Improved radial GRAPPA calibration for real-time freebreathing cardiac imaging", Magn Reson Med, 65, pp.492~505 (2011)
- Seiberlich N, "Improved temporal resolution in cardiac imaging using through-time spiral GRAPPA", Magn Reson Med, 66, pp.1682~1688 (2011)
- Walsh DO, "Adaptive reconstruction of phased array MR imagery", Magn Reson Med, 43, pp.682~690 (2000)
- Pruessmann KP, "Advances in sensitivity encoding with arbitrary k-space trajectories", Magn Reson Med, 46, pp.638~651 (2001)
- Ying L, "Joint image reconstruction and sensitivity estimation in SENSE(JSENSE)", Magn Reson Med, 57, pp.1196~1202 (2007)
- Uecker M, "Image reconstruction by regularized nonlinear inversion--joint estimation of coil sensitivities and image content", Magn Reson Med, 60, pp.674~682 (2008)
- Bakushinsky AB, "Iterative methods for approximate solution of inverse problems. Mathematics and its applications" (2005), Springer Science & Business Media
- Engl HW, "Regularization of inverse problems (Vol. 375)" (1996), Springer Science & Business Media
- Uecker M, "Real-time MRI at a resolution of 20 ms", NMR Biomed, 23, pp.986~994 (2010)
- Wajer FTAW, "Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories", Proc Intl Soc Mag Res Med, pp.767~ (2001)
- Uecker M, "Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH", Magn Reson Med, 63, pp.1456~1462 (2010)
- Zhang S, "Real-time cardiovascular magnetic resonance at high temporal resolution : radial FLASH with nonlinear inverse reconstruction", J Cardiovasc Magn Reson, 12, pp.39~ (2010)
- Unterberg-Buchwald C, "Targeted endomyocardial biopsy guided by real-time cardiovascular magnetic resonance", J Cardiovasc Magn Reson, 19, pp.45~ (2017)
- Campbell-Washburn AE, "Realtime MRI guidance of cardiac interventions", J Magn Reson Imaging, 46, pp.935~950 (2017)
- Backhaus SJ, "Exercise stress realtime cardiac magnetic resonance imaging for noninvasive characterization of heart failure with preserved ejection fraction : the HFpEF-Stress trial", Circulation, 143, pp.1484~1498 (2021)
- Schaetz S, "Accelerated computing in magnetic resonance imaging : real-time imaging using nonlinear inverse reconstruction", Comput Math Methods Med, 2017, pp.3527269~ (2017)
- Block KT, "Model-based iterative reconstruction for radial fast spin-echo MRI", IEEE Trans Med Imaging, 28, pp.1759~1769 (2009)
- Fessler JA, "Model-based image reconstruction for MRI", IEEE Signal Process Mag, 27, pp.81~89 (2010)
- Tan Z, "Model-based reconstruction for real-time phase-contrast flow MRI : improved spatiotemporal accuracy", Magn Reson Med, 77, pp.1082~1093 (2017)
- Wang X, "Model-based T1 mapping with sparsity constraints using singleshot inversion-recovery radial FLASH", Magn Reson Med, 79, pp.730~740 (2018)
- Wang X, "Physics-based reconstruction methods for magnetic resonance imaging", Philos Trans A Math Phys Eng Sci, 379, pp.20200196~ (2021)
- Donoho DL, "Compressed sensing", IEEE Trans Inf Theory, 52, pp.1289~1306 (2006)
- Candès EJ, "Robust uncertainty principles : exact signal reconstruction from highly incomplete frequency information", IEEE Trans Inf Theory, 52, pp.489~509 (2006)
- Lustig M, "Sparse MRI : the application of compressed sensing for rapid MR imaging", Magn Reson Med, 58, pp.1182~1195 (2007)
- Block KT, "Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint", Magn Reson Med, 57, pp.1086~1098 (2007)
- Gamper U, "Compressed sensing in dynamic MRI", Magn Reson Med, 59, pp.365~373 (2008)
- Feng L, "Compressed sensing for body MRI", J Magn Reson Imaging, 45, pp.966~987 (2017)
- Liang D, "Accelerating SENSE using compressed sensing", Magn Reson Med, 62, pp.1574~1584 (2009)
- Otazo R, "Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI", Magn Reson Med, 64, pp.767~776 (2010)
- Lustig M, "k-t SPARSE:high frame rate dynamic MRI exploiting spatio-temporal sparsity", Proceedings of the 13th Annual Meeting of ISMRM, pp.2420~ (2006)
- Usman M, "k-t Group sparse : a method for accelerating dynamic MRI", Magn Reson Med, 66, pp.1163~1176 (2011)
- Ting ST, "Sub-30 ms real-time, free-breathing cardiac imaging with SPIRiT", J Cardiovasc Magn Reson, 16, pp.1~3 (2014)
- Ting ST, "Fast implementation for compressive recovery of highly accelerated cardiac cine MRI using the balanced sparse model", Magn Reson Med, 77, pp.1505~1515 (2017)
- Ye JC, "Compressed sensing MRI : a review from signal processing perspective", BMC Biomed Eng, 1, pp.1~17 (2019)
- Feng L, "Highly accelerated realtime cardiac cine MRI using k-t SPARSE-SENSE", Magn Reson Med, 70, pp.64~74 (2013)
- Hager W, "A new conjugate gradient method with guaranteed descent and an efficient line search", SIAM J Optim, 16, pp.170~192 (2005)
- Daubechies I, "An iterative thresholding algorithm for linear inverse problems with a sparsity constraint", Commun Pure Appl Math, 57, pp.1413~1457 (2004)
- Beck A, "A fast iterative shrinkage-thresholding algorithm for linear inverse problems", SIAM J Imaging Sci, 2, pp.183~202 (2009)
- Boyd S, "Distributed optimization and statistical learning via the alternating direction method of multipliers", Found Trends Mach Learn, 3, pp.1~122 (2011)
- Liu J, "Dynamic cardiac MRI reconstruction with weighted redundant Haar wavelets", Proceedings of the 20th Annual Meeting of the ISMRM, pp.4249~ (2012)
- Qu X, "Magnetic resonance image reconstruction from undersampled measurements using a patch-based nonlocal operator", Med Image Anal, 18, pp.843~856 (2014)
- Aharon M, "K-SVD : an algorithm for designing overcomplete dictionaries for sparse representation", IEEE Trans Signal Process, 54, pp.4311~4322 (2006)
- Ravishankar S, "MR image reconstruction from highly undersampled k-space data by dictionary learning", IEEE Trans Med Imaging, 30, pp.1028~1041 (2011)
- Caballero J, "Dictionary learning and time sparsity for dynamic MR data reconstruction", IEEE Trans Med Imaging, 33, pp.979~994 (2014)
- Brinegar C, "Real-time cardiac MRI without triggering, gating, or breath holding", Annu Int Conf IEEE Eng Med Biol Soc, 2008, pp.3381~3384 (2008)
- Zhao B, "Low rank matrix recovery for real-time cardiac MRI", Proc IEEE Int Symp Biomed Imaging, pp.996~999 (2010)
- Lingala SG, "Accelerated dynamic MRI exploiting sparsity and low-rank structure : k-t SLR", IEEE Trans Med Imaging, 30, pp.1042~1054 (2011)
- Zhao B, "Image reconstruction from highly undersampled (k, t)-space data with joint partial separability and sparsity constraints", IEEE Trans Med Imaging, 31, pp.1809~1820 (2012)
- Liang ZP, "Spatiotemporal imaging with partially separable functions", Proc IEEE Int Symp Biomed Imaging, pp.988~991 (2007)
- Batchelor PG, "Matrix description of general motion correction applied to multishot images", Magn Reson Med, 54, pp.1273~1280 (2005)
- Hansen MS, "Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction", Magn Reson Med, 68, pp.741~750 (2012)
- Xue H, "High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions", J Cardiovasc Magn Reson, 15, pp.1~15 (2013)
- Usman M, "Motion corrected compressed sensing for free-breathing dynamic cardiac MRI", Magn Reson Med, 70, pp.504~516 (2013)
- Li H, "Aggregated motion estimation for real-time MRI reconstruction", Magn Reson Med, 72, pp.1039~1048 (2014)
- Feng L, "Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI", Magn Reson Med, 72, pp.707~717 (2014)
- Feng L, "XD-GRASP : golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing", Magn Reson Med, 75, pp.775~788 (2016)
- Poddar S, "Dynamic MRI using smoothness regularization on manifolds(SToRM)", IEEE Trans Med Imaging, 35, pp.1106~1115 (2016)
- Christodoulou AG, "Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging", Nat Biomed Eng, 2, pp.215~226 (2018)
- Shaw JL, "Free-breathing, non-ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking", Magn Reson Med, 81, pp.2450~2463 (2019)
- Wang N, "Six-dimensional quantitative DCE MR multitasking of the entire abdomen : method and application to pancreatic ductal adenocarcinoma", Magn Reson Med, 84, pp.928~948 (2020)
- Cheng JY, "Comprehensive motion-compensated highly accelerated 4D flow MRI with ferumoxytol enhancement for pediatric congenital heart disease", J Magn Reson Imaging, 43, pp.1355~1368 (2016)
- Cheng JY, "Comprehensive multidimensional MRI for the simultaneous assessment of cardiopulmonary anatomy and physiology", Sci Rep, 7, pp.5330~ (2017)
- Winkelmann S, "An optimal radial profile order based on the golden ratio for time-resolved MRI", IEEE Trans Med Imaging, 26, pp.68~76 (2007)
- Larson AC, "Self-gated cardiac cine MRI", Magn Reson Med, 51, pp.93~102 (2004)
- Rosenzweig S, "Cardiac and respiratory self-gating in radial MRI using an adapted singular spectrum analysis(SSA-FARY)", IEEE Trans Med Imaging, 39, pp.3029~3041 (2020)
- Wang S, "Accelerating magnetic resonance imaging via deep learning", Proc IEEE Int Symp Biomed Imaging, 2016, pp.514~517 (2016)
- Hammernik K, "Learning a variational network for reconstruction of accelerated MRI data", Magn Reson Med, 79, pp.3055~3071 (2018)
- Schlemper J, "A deep cascade of convolutional neural networks for dynamic MR image reconstruction", IEEE Trans Med Imaging, 37, pp.491~503 (2018)
- Aggarwal HK, "MoDL : model-based deep learning architecture for inverse problems", IEEE Trans Med Imaging, 38, pp.394~405 (2019)
- Luo G, "MRI reconstruction using deep Bayesian estimation", Magn Reson Med, 84, pp.2246~2261 (2020)
- Knoll F, "Deep-learning methods for parallel magnetic resonance imaging reconstruction: a survey of the current approaches, trends, and issues", IEEE Signal Process Mag, 37, pp.128~140 (2020)
- He Z, "Study of the interactivity between mercury and cellular system labeled with carboxymethyl chitosan-coated quantum dots and its application in a real-time in-situ detection of mercury", Spectrochim Acta A Mol Biomol Spectrosc, 139, pp.179~183 (2015)
- Ziwen Ke, "Cascaded Residual Dense Networks for Dynamic MR Imaging with Edge-Enhanced Loss Constraint", Investigative Magnetic Resonance Imaging, 24(4), pp.214~222 (2020), 대한자기공명의과학회
- Park SJ, "Blended-transfer learning for compressedsensing cardiac CINE MRI", Investig Magn Reson Imaging, 25, pp.10~22 (2021)
- Hauptmann A, "Real-time cardiovascular MR with spatiotemporal artifact suppression using deep learning-proof of concept in congenital heart disease", Magn Reson Med, 81, pp.1143~1156 (2019)
- Wundrak S, "Golden ratio sparse MRI using tiny golden angles", Magn Reson Med, 75, pp.2372~2378 (2016)