본문 바로가기
KERD
논문KCI 등재

Micro-CT evaluation of internal adaptation in resin fillings with different dentin adhesives

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: The purpose of present study was to evaluate the internal adaptation ofcomposite restorations using different adhesive systems. Materials and Methods:Typical class I cavities were prepared in 32 human third molars. The teeth were dividedinto the following four groups: 3-step etch-and-rinse, 2-step etch-and-rinse, 2-stepself-etch and 1-step self-etch system were used. After the dentin adhesives wereapplied, composite resins were filled and light-cured in two layers. Then, silver nitratesolution was infiltrated, and all of the samples were scanned by micro-CT before andafter thermo-mechanical load cycling. For each image, the length to which silvernitrate infiltrated, as a percentage of the whole pulpal floor length, was calculated(%SP). To evaluate the internal adaptation using conventional method, the sampleswere cut into 3 pieces by two sectioning at an interval of 1 mm in the middle of thecavity and they were dyed with Rhodamine-B. The cross sections of the specimenswere examined by stereomicroscope. The lengths of the parts where actual leakagewas shown were measured and calculated as a percentage of real leakage (%RP). Thevalues for %SP and %RP were compared. Results: After thermo-mechanical loading, allspecimens showed significantly increased %SP compared to before thermo-mechanicalloading and 1-step self-etch system had the highest %SP (p < 0.05). There was atendency for %SP and %RP to show similar microleakage percentage depending on itssectioning. Conclusions: After thermo-mechanical load cycling, there were differencesin internal adaptation among the groups using different adhesive systems.

Abstract

Objectives: The purpose of present study was to evaluate the internal adaptation ofcomposite restorations using different adhesive systems. Materials and Methods:Typical class I cavities were prepared in 32 human third molars. The teeth were dividedinto the following four groups: 3-step etch-and-rinse, 2-step etch-and-rinse, 2-stepself-etch and 1-step self-etch system were used. After the dentin adhesives wereapplied, composite resins were filled and light-cured in two layers. Then, silver nitratesolution was infiltrated, and all of the samples were scanned by micro-CT before andafter thermo-mechanical load cycling. For each image, the length to which silvernitrate infiltrated, as a percentage of the whole pulpal floor length, was calculated(%SP). To evaluate the internal adaptation using conventional method, the sampleswere cut into 3 pieces by two sectioning at an interval of 1 mm in the middle of thecavity and they were dyed with Rhodamine-B. The cross sections of the specimenswere examined by stereomicroscope. The lengths of the parts where actual leakagewas shown were measured and calculated as a percentage of real leakage (%RP). Thevalues for %SP and %RP were compared. Results: After thermo-mechanical loading, allspecimens showed significantly increased %SP compared to before thermo-mechanicalloading and 1-step self-etch system had the highest %SP (p < 0.05). There was atendency for %SP and %RP to show similar microleakage percentage depending on itssectioning. Conclusions: After thermo-mechanical load cycling, there were differencesin internal adaptation among the groups using different adhesive systems.

참고문헌 (40)

  1. Bausch JR, "Clinical significance of polymerization shrinkage of composite resins", J Prosthet Dent, 48, pp.59~67 (1982)
  2. Eick JD, "Polymerization shrinkage of posterior composite resins and its possible influence on postoperative sensitivity", Quintessence Int, 17, pp.103~111 (1986)
  3. Hilton TJ., "Can modern restorative procedures and materials reliably seal cavities? In vitro investigations. Part 2", Am J Dent, 15, pp.279~289 (2002)
  4. Alani AH, "Detection of microleakage around dental restorations: a review", Oper Dent, 22, pp.173~185 (1997)
  5. Heintze S, "Microleakage of Class II restorations with different tracers-comparison with SEM quantitative analysis", J Adhes Dent, 10, pp.259~267 (2008)
  6. Bouillaguet S, "Ability of adhesive systems to seal dentin surfaces: an in vitro study", J Adhes Dent, 2, pp.201~208 (2000)
  7. Del-Nero MO, "Analysis of sealing vs tensile bond strength of eight adhesive restorative material systems", J Adhes Dent, 2, pp.117~127 (2000)
  8. De Munck J, "A critical review of the durability of adhesion to tooth tissue:methods and results", J Dent Res, 84, pp.118~132 (2005)
  9. De Santis R, "A 3D analysis of mechanically stressed dentin-adhesive-composite interfaces using X-ray micro-CT", Biomaterials, 26, pp.257~270 (2005)
  10. Eden E, "Micro-CT for measuring marginal leakage of Class II resin composite restorations in primary molars prepared in vivo", Am J Dent, 21 (2008)
  11. Sun J, "3D mapping of polymerization shrinkage using X-ray micro-computed tomography to predict microleakage", Dent Mater, 25, pp.314~320 (2009)
  12. Kakaboura A, "3D-marginal adaptation versus setting shrinkage in light-cured microhybrid resin composites", Dent Mater, 23, pp.272~278 (2007)
  13. Zeiger DN, "Evaluation of dental composite shrinkage and leakage in extracted teeth using X-ray microcomputed tomography", Dent Mater, 25, pp.1213~1220 (2009)
  14. 권오현, "Evaluation of internal adaptation of dental adhesive restorations using micro-CT", Restorative Dentistry and Endodontics, 37(1), pp.41~49 (2012), 대한치과보존학회
  15. De Munck J, "Four-year water degradation of total-etch adhesives bonded to dentin", J Dent Res, 82, pp.136~140 (2003)
  16. Devarasa GM, "Self-etching adhesive on intact enamel, with and without pre-etching", Microsc Res Tech, 75, pp.650~654 (2012)
  17. Van Landuyt KL, "Are onestep adhesives easier to use and better performing? Multifactorial assessment of contemporary one-step self-etching adhesives", J Adhes Dent, 11, pp.175~190 (2009)
  18. Sadek FT, "Microtensile bond strength of current dentin adhesives measured immediately and 24 hours after application", J Adhes Dent, 7, pp.297~302 (2005)
  19. Tay FR, "Single-step, self-etch adhesives behave as permeable membranes after polymerization. Part I. Bond strength and morphologic evidence", Am J Dent, 17, pp.271~278 (2004)
  20. Hashimoto M, "In vivo degradation of resin-dentin bonds in humans over 1 to 3 years", J Dent Res, 79, pp.1385~1391 (2000)
  21. Shono Y, "Carvalho RM, Russell CM, Pashley DH. Durability of resin-dentin bonds", J Adhes Dent, 1, pp.211~218 (1999)
  22. Leloup G, "Meta-analytical review of factors involved in dentin adherence", J Dent Res, 80, pp.1605~1614 (2001)
  23. Nikaido T, "Evaluation of thermal cycling and mechanical loading on bond strength of a self-etching primer system to dentin", Dent Mater, 18, pp.269~275 (2002)
  24. Abdalla AI, "Effect of mechanical load cycling on the marginal integrity of adhesive Class I resin composite restorations", J Dent, 24, pp.87~90 (1996)
  25. Mitsui FH, "Influence of load cycling on marginal microleakage with two self-etching and two onebottle dentin adhesive systems in dentin", J Adhes Dent, 5, pp.209~216 (2003)
  26. Krejci I, "New adhesives in Class V restorations under combined load and simulated dentinal fluid", Dent Mater, 10, pp.331~335 (1994)
  27. Frankenberger R, "Evaluation of the fatigue behavior of the resin-dentin bond with the use of different methods", J Biomed Mater Res B Appl Biomater, 67, pp.712~721 (2003)
  28. Van Meerbeek B, "Technique-sensitivity of contemporary adhesives", Dent Mater J, 24, pp.1~13 (2005)
  29. Van Landuyt KL., "Optimization of the chemical composition of dental adhesives: towards a simplified and durable, universal enamel", dentin adhesives, KU Leuven, 2008
  30. Shirai K, "Effect of cavity configuration and aging on the bonding effectiveness of six adhesives to dentin", Dent Mater, 21, pp.110~124 (2005)
  31. Walter R, "Two-year bond strengths of “all-in-one” adhesives to dentine", J Dent, 40, pp.549~555 (2012)
  32. Tay FR, "How can nanoleakage occur in self-etching adhesive systems that demineralize and infiltrate simultaneously?", J Adhes Dent, 4, pp.255~269 (2002)
  33. Tay FR, "Pashley DH, Yoshiyama M. Two modes of nanoleakage expression in single-step adhesives", J Dent Res, 81, pp.472~476 (2002)
  34. Van Landuyt KL, "Monomer-solvent phase separation in one-step self-etch adhesives", J Dent Res, 84, pp.183~188 (2005)
  35. Van Meerbeek B, "State of the art of self-etch adhesives", Dent Mater, 27, pp.17~28 (2011)
  36. Pashley DH, "State of the art etch-and-rinse adhesives", Dent Mater, 27, pp.1~16 (2011)
  37. Zheng L, "Relationship between adhesive thickness and microtensile bond strength", Oper Dent, 26, pp.97~104 (2001)
  38. Loguercio AD, "Durability of enamel bonding using two-step self-etch systems on ground and unground enamel", Oper Dent, 33, pp.79~88 (2008)
  39. Gamborgi GP, "Influence of enamel border and regional variability on durability of resindentin bonds", J Dent, 35, pp.371~376 (2007)
  40. Banomyong D, "Sealing ability of occlusal resin composite restoration using four restorative procedures", Eur J Oral Sci, 116, pp.571~578 (2008)

관련 논문AI추천