Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.
Abstract
Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.
참고문헌 (34)
- Mahmound SH, "Marginal adaptation of ormocer-, silorane-, and methacrylate-based composite restorative systems bonded to dentin cavities after water storage", Quintessence Int, 42, pp.e131~e139 (2011)
- Czasch P, "In vitro comparison of mechanical properties and degree of cure of bulk fill composites", Clin Oral Investig, 17, pp.227~235 (2013)
- Ilie N, "Investigations on a methacrylatebased flowable composite based on the SDR technology", Dent Mater, 27, pp.348~355 (2011)
- El-Damanhoury H, "Polymerization shrinkage stress kinetic and related properties of bulk-fill resin composites", Oper Dent, 39, pp.374~382 (2014)
- Moorthy A, "Cuspal deflection and microleakage in premolar teeth restored with bulkfill flowable resin-based composite base materials", J Dent, 40, pp.500~505 (2012)
- El-Safty S, "Creep deformation of restorative resin-composites intended for bulk-fill placement", Dent Mater, 28, pp.928~935 (2012)
- Naoum SJ, "Polymerization profile analysis of resin composite dental restorative materials in real time", J Dent, 40, pp.64~70 (2012)
- Ilie N, "Curing behaviour of high-viscosity bulk-fill composites", J Dent, 42, pp.977~985 (2014)
- Alrahlah A, "Post-cure depth of cure of bulk fill dental resin-composites", Dent Mater, 30, pp.149~154 (2014)
- Ilie N, "Influence of various irradiation processes on the mechanical properties and polymerization kinetics of bulk-fill resin based composites", J Dent, 41, pp.695~702 (2013)
- Flury S, "Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials?", Dent Mater, 28, pp.521~528 (2012)
- Abbas G, "Cuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments", J Dent, 31, pp.437~444 (2003)
- Tiba A, "A laboratory evaluation of bulk-fill versus traditional multiincrement-fill resin-based composites", J Am Dent Assoc, 144, pp.1182~1183 (2013)
- Watts DC, "Reaction kinetics and mechanics in photo-polymerised networks", Dent Mater, 21, pp.27~35 (2005)
- Yoon TH, "Degree of polymerization of resin composites by different light sources", J Oral Rehabil, 29, pp.1165~1173 (2002)
- Price RB, "Comparison of quartz-tungsten-halogen, light-emitting diode, and plasma arc curing lights", J Adhes Dent, 5, pp.193~207 (2003)
- Rueggeberg F, "Contemporary issues in photocuring", Compend Contin Educ Dent Suppl, 25, pp.S4~S15 (1999)
- Visvanathan A, "The influence of curing times and light curing methods on the polymerization shrinkage stress of a shrinkage-optimized composite with hybrid-type prepolymer fillers", Dent Mater, 23, pp.777~784 (2007)
- Dewaele M, "Class II restorations: influence of a liner with rubbery qualities on the occurrence and size of cervical gaps", Eur J Oral Sci, 114, pp.535~541 (2006)
- Feilzer AJ, "Influence of light intensity on polymerization shrinkage and integrity of restoration-cavity interface", Eur J Oral Sci, 103, pp.322~326 (1995)
- Atai M, "A new kinetic model for the photopolymerization shrinkage-strain of dental composites and resin monomers", Dent Mater, 22, pp.785~791 (2006)
- Pongprueksa P, "The elastic moduli across various types of resin", dentin interfaces, 2008, pp.24, 1102~1106
- Bouschlicher MR, "Effect of stepped light intensity on polymerization force and conversion in a photoactivated composite", J Esthet Dent, 12, pp.23~32 (2000)
- Ilie N, "Curing behaviour of high-viscosity bulk-fill composites", J Dent, 42, pp.977~985 (2014)
- Ilie N, "Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance", Oper Dent, 38, pp.618~625 (2013)
- Li X, "Curing profile of bulk-fill resin-based composites", J Dent, 43, pp.664~672 (2015)
- Garcia D, "Polymerization shrinkage and depth of cure of bulk fill flowable composite resins", Oper Dent, 39, pp.441~448 (2014)
- Benetti AR, "Bulk-fill resin composites:polymerization contraction, depth of cure, and gap formation", Oper Dent, 40, pp.190~200 (2015)
- Jang JH, "Polymerization shrinkage and depth of cure of bulk-fill resin composites and highly filled flowable resin", Oper Dent, 40, pp.172~180 (2015)
- Eden E, "Micro-CT for measuring marginal leakage of Class II resin composite restorations in primary molars prepared in vivo", Am J Dent, 21, pp.393~397 (2008)
- Zhao XY, "Detection of marginal leakage of Class V restorations in vitro by microcomputed tomography", Oper Dent, 39, pp.174~180 (2014)
- Chen X, "Validation of micro-CT against the section method regarding the assessment of marginal leakage of sealant", Aust Dent J, 57, pp.196~199 (2012)
- Raskin A, "Influence of the number of sections on reliability of in vitro microleakage evaluations", Am J Dent, 16, pp.207~210 (2003)
- Abdalla AI, "Comparison of the marginal integrity of in vivo and in vitro Class II composite restorations", J Dent, 21, pp.158~162 (1993)
