The effect of various thread designs on the initial stability of taper implants

2

조회

0

다운로드

5

인용

0

참고문헌

키워드

초록

STATEMENT OF PROBLEM. Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE. The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone (Group 1) and the rest of which were not engaged to inferior cortical wall (Group 2) by measuring the implant stability quotient (ISQ) and the removal torque value (RTV). MATERIAL AND METHODS. In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer’s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell mentor® and with removal torque using MGT50 torque gauge. RESULTS. In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants (P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not (P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2 (P < .05). CONCLUSIONS. Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.

Abstract

STATEMENT OF PROBLEM. Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE. The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone (Group 1) and the rest of which were not engaged to inferior cortical wall (Group 2) by measuring the implant stability quotient (ISQ) and the removal torque value (RTV). MATERIAL AND METHODS. In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer’s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell mentor® and with removal torque using MGT50 torque gauge. RESULTS. In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants (P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not (P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2 (P < .05). CONCLUSIONS. Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.

참고문헌 (21)

  1. Scarano A, "Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans", Clin Implant Dent Relat, 8, pp.218~222 (2006)
  2. O’Sullivan D, "Measurements comparing the initial stability of five designs of dental implants: a human cadaver study", Implant Dent Relat Res, 2, pp.85~92 (2000)
  3. Alsaadi G, "A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment", J Clin Periodontol, 34, pp.359~366 (2007)
  4. Johansson P, "Assessment of bone quality from placement resistance during implant surgery", Int J Oral Maxillofac Implants, 9, pp.279~288 (1994)
  5. Tricio J, "Mechanical state assessment of the implant-bone continuum: a better understanding of the Periotest method", Int J Oral Maxillofac Implants, 10, pp.43~49 (1995)
  6. Rasmusson L, "Stability assessments and histology of titanium implants placed simultaneously with autogenous onlay bone in the rabbit tibia", Int J Oral Maxillofac Surg, 27, pp.229~235 (1998)
  7. Ueda M, "Relationship between insertion torque and removal torque analyzed in fresh temporal bone", Int J Oral Maxillofac Implants, 6, pp.442~447 (1991)
  8. Ivanoff CJ, "Influence of variations in implant diameters: a 3- to 5-year retrospective clinical report", Int J Oral Maxillofac Implants, 14, pp.173~180 (1999)
  9. Steigenga JT, "Dental implant design and its relationship to long-term implant success", Implant Dent, 12, pp.306~317 (2003)
  10. Block CM, "Histologic evaluation of the LaminOss osteocompressive dental screw: a pilot study", Compend Contin Educ Dent, 18, pp.676~680 (1997)
  11. Balleri P, "Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study", Clin Implant Dent Relat Res, 4, pp.128~132 (2002)
  12. Miyamoto I, "Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospective, biomechanical, and imaging study", Bone, 37, pp.776~780 (2005)
  13. Nkenke E, "Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants", Clin Oral Implants Res, 14, pp.601~609 (2003)
  14. Ostman PO, "Resonance frequency analysis measurements of implants at placement surgery", Int J Prosthodont, 19, pp.77~83 (2006)
  15. da Cunha HA, "A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading", Int J Oral Maxillofac Implants, 19, pp.578~585 (2004)
  16. Zix J, "Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study", Int J Oral Maxillofac Implants, 20, pp.747~752 (2005)
  17. Rocci A, "Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible", Clin Implant Dent Relat Res, 5, pp.88~98 (2003)
  18. Rabel A, "Clinical study on the primary stability of two dental implant systems with resonance frequency analysis", Clin Oral Investig, 11, pp.257~265 (2007)
  19. Fernandes Ede L, "Primary stability of turned and acid-etched screwtype implants: a removal torque and histomorphometric study in rabbits", Int J Oral Maxillofac Implants, 22, pp.886~892 (2007)
  20. Akkocaoglu M, "Primary stability of simultaneously placed dental implants in extraoral donor graft sites: a human cadaver study", J Oral Maxillofac Surg, 65, pp.400~407 (2007)
  21. Niimi A, "A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: preliminary report", Clin Oral Implants Res, 8, pp.286~289 (1997)

관련 논문AI추천

The effect of implant shape and bone preparation on primary stability문상현, 엄흥식, 이민구, 이재관, 장범석대한치주과학회 · Journal of Periodontal & Implant Science2010 · 제40권 제5호Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test구영, 구기태, 김명덕, 김병국, 김성태, 김태일, 님궁희, 류인철, 설양조, 이용무, 이은희, Dorjpalam Bayarchimeg대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제1호The effect of the thread depth on the mechanical properties of the dental implant김성준, 김현승, 노경호, 박광범, 안현욱, 이선영, 하동국대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제2호Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study허익, 신승윤, 신승일, 안수진, 임현창, 정종혁, 한지영, 한호철, 홍지연대한치주과학회 · Journal of Periodontal & Implant Science2016 · 제46권 제4호The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribsAdriano Piattelli, Claudia Cappucci, Danilo Alessio Di Stefano, Gian Battista Greco, Giovanna Iezzi, Paolo Arosio, Vittoria Perrotti대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제3호Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value곽재영, 김성균, 윤홍기, 이수영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제1호

이 간행물의 다른 논문 (9건)