Bone cement grafting increases implant primary stability in circumferential cortical bone defects
1
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Purpose: Implant beds with an insufficient amount of cortical bone or a loss of corticalbone can result in the initial instability of a dental implant. Thus, the objective of this studywas to evaluate the effect of bone cement grafting on implant initial stability in areas withinsufficient cortical bone. Methods: Two different circumferential defect depths (2.5 mm and 5 mm) and a control(no defect) were prepared in six bovine rib bones. Fourteen implants of the same type andsize (4 mm×10 mm) were placed in each group. The thickness of the cortical bone wasmeasured for each defect. After the implant stability quotient (ISQ) values were measuredthree times in four different directions, bone cement was grafted to increase the primarystability of the otherwise unstable implant. After grafting, the ISQ values were measuredagain. Results: As defect depth increased, the ISQ value decreased. In the controls, the ISQ valuewas 85.45±3.36 (mean±standard deviation). In circumferential 2.5-mm and 5-mm defectgroups, the ISQ values were 69.42±7.06 and 57.43±6.87, respectively, before grafting. These three values were significantly different (P<0.001). After grafting the bone cement,the ISQ values significantly increased to 73.72±8.00 and 67.88±10.09 in the 2.5-mm and5.0-mm defect groups, respectively (P<0.05 and P<0.001). The ISQ value increased tomore than double that before grafting in the circumferential 5-mm defect group. The ISQvalues did not significantly differ when measured in any of the four directions. Conclusions: The use of bone cement remarkably increased the stability of the implantthat otherwise had an insufficient level of stability at placement, which was caused by insufficientcortical bone volume.
Abstract
Purpose: Implant beds with an insufficient amount of cortical bone or a loss of corticalbone can result in the initial instability of a dental implant. Thus, the objective of this studywas to evaluate the effect of bone cement grafting on implant initial stability in areas withinsufficient cortical bone. Methods: Two different circumferential defect depths (2.5 mm and 5 mm) and a control(no defect) were prepared in six bovine rib bones. Fourteen implants of the same type andsize (4 mm×10 mm) were placed in each group. The thickness of the cortical bone wasmeasured for each defect. After the implant stability quotient (ISQ) values were measuredthree times in four different directions, bone cement was grafted to increase the primarystability of the otherwise unstable implant. After grafting, the ISQ values were measuredagain. Results: As defect depth increased, the ISQ value decreased. In the controls, the ISQ valuewas 85.45±3.36 (mean±standard deviation). In circumferential 2.5-mm and 5-mm defectgroups, the ISQ values were 69.42±7.06 and 57.43±6.87, respectively, before grafting. These three values were significantly different (P<0.001). After grafting the bone cement,the ISQ values significantly increased to 73.72±8.00 and 67.88±10.09 in the 2.5-mm and5.0-mm defect groups, respectively (P<0.05 and P<0.001). The ISQ value increased tomore than double that before grafting in the circumferential 5-mm defect group. The ISQvalues did not significantly differ when measured in any of the four directions. Conclusions: The use of bone cement remarkably increased the stability of the implantthat otherwise had an insufficient level of stability at placement, which was caused by insufficientcortical bone volume.
참고문헌 (27)
- Albrektsson T, "Current interpretations of the osseointegrated response: clinical significance", Int J Prosthodont, 6, pp.95~105 (1993)
- Lioubavina-Hack N, "Significance of primary stability for osseointegration of dental implants", Clin Oral Implants Res, 17, pp.244~250 (2006)
- Dorjpalam Bayarchimeg, "Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test", Journal of Periodontal & Implant Science, 43(1), pp.30~36 (2013), 대한치주과학회
- Hong J, "Quantitative biomechanical analysis of the influence of the cortical bone and implant length on primary stability", Clin Oral Implants Res, 23, pp.1193~1197 (2012)
- Javed F, "Osseointegration of dental implants in patients undergoing bisphosphonate treatment: a literature review", J Periodontol, 81, pp.479~484 (2010)
- Javed F, "Impact of diabetes mellitus and glycemic control on the osseointegration of dental implants: a systematic literature review", J Periodontol, 80, pp.1719~1730 (2009)
- Roze J, "Correlating implant stability to bone structure", Clin Oral Implants Res, 20, pp.1140~1145 (2009)
- Tabassum A, "Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study", Clin Oral Implants Res, 20, pp.327~332 (2009)
- Tabassum A, "Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study", Clin Oral Implants Res, 21, pp.213~220 (2010)
- Seong WJ, "Ex vivo mechanical properties of dental implant bone cement used to rescue initially unstable dental implants: a rabbit study", Int J Oral Maxillofac Implants, 26, pp.826~836 (2011)
- Seung-Yun Shin, "The Effects of Defect Type and Depth, and Measurement Direction on the Implant Stability Quotient (ISQ) Value", Journal of Oral Implantology, pp.141208072802005~ (2014), American Academy of Implant Dentistry[DOI]
- Jin Hoon Park, "Radiographic Analysis of Instrumented Posterolateral Fusion Mass Using Mixture of Local Autologous Bone and b-TCP (PolyBone^®) in a Lumbar Spinal Fusion Surgery", 대한신경외과학회지, 49(5), pp.267~272 (2011), 대한신경외과학회
- Park JH, "Anterior cervical interbody fusion using polyetheretherketone cage filled with autologous and synthetic bone graft substrates for cervical spondylosis: comparative analysis between PolyBone® and iliac bone", Neurol Med Chir (Tokyo), 53, pp.85~90 (2013)
- Park YH, "Obliteration of temporal dorsal bulla in guinea pigs using different types of calcium phosphate", Int J Pediatr Otorhinolaryngol, 75, pp.1176~1180 (2011)
- Abbah SA, "Biological performance of a polycaprolactone-based scaffold used as fusion cage device in a large animal model of spinal reconstructive surgery", Biomaterials, 30, pp.5086~5093 (2009)
- Byun HY, "Sandwich bone augmentation using recombinant human platelet-derived growth factor and beta-tricalcium phosphate alloplast: case report", Int J Periodontics Restorative Dent, 28, pp.83~87 (2008)
- 차재국, "Case series of maxillary sinus augmentation with biphasic calcium phosphate: a clinical and radiographic study", Journal of Periodontal & Implant Science, 41(2), pp.98~104 (2011), 대한치주과학회
- Elahi MM, "Frontal sinus obliteration with beta-tricalcium phosphate", J Craniofac Surg, 15, pp.967~970 (2004)
- Kishimoto M, "Cranial bone regeneration using a composite scaffold of Beta-tricalcium phosphate, collagen, and autologous bone fragments", Laryngoscope, 116, pp.212~216 (2006)
- Suba Z, "Maxillary sinus floor grafting with beta-tricalcium phosphate in humans: density and microarchitecture of the newly formed bone", Clin Oral Implants Res, 17, pp.102~108 (2006)
- Sennerby L, "Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications", Periodontol 2000, 47, pp.51~66 (2008)
- Ivanoff CJ, "Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits", Clin Oral Implants Res, 7, pp.120~127 (1996)
- Morris HF, "AICRG, Part V: Factors influencing implant stability at placement and their influence on survival of Ankylos implants", J Oral Implantol, 30, pp.162~170 (2004)
- Herr Y, "Atlas of periodontology-based implantology I" (2012), Yenang Inc
- Fischer K, "Five-year results from a randomized, controlled trial on early and delayed loading of implants supporting full-arch prosthesis in the edentulous maxilla", Clin Oral Implants Res, 19, pp.433~441 (2008)
- Valderrama P, "Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial", J Periodontol, 78, pp.262~272 (2007)
- Veltri M, "Influence of transducer orientation on Osstell stability measurements of osseointegrated implants", Clin Implant Dent Relat Res, 9, pp.60~64 (2007)
