Primary stability of implants with peri-implant bone defects of various widths: an in vitro investigation
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: This study aimed to evaluate the effects of i) the extent of peri-implant bone defects and ii) the application of bone cement on implant stability with respect to the measurement direction. Methods: In 10 bovine rib bones, 4 implant osteotomies with peri-implant bone defects of various widths were prepared: i) no defect (D0), ii) a 2-mm-wide defect (D2), iii) a 4-mm-wide defect (D4), and iv) a 8-mm-wide defect (D8). The height of all defects was 10 mm. Implant stability quotient (ISQ) values and Periotest values (PTVs) were measured after implant placement and bone cement application. Results: With increasing defect width, decreased ISQs and increased PTVs were observed. Statistically significant differences were found between groups D0 and D8, D0 and D4, and D2 and D8. Prior to bone cement application, inconsistent PTVs were found in group D8 depending on the measurement direction. Bone cement increased the implant stability. Conclusion: Peri-implant bone deficits measuring around 50% of the implant surface compromised implant stability. Clinically, PTVs should be cautiously interpreted in implants with large peri-implant defects due to inconsistent recordings with respect to the measurement direction.
Abstract
Purpose: This study aimed to evaluate the effects of i) the extent of peri-implant bone defects and ii) the application of bone cement on implant stability with respect to the measurement direction. Methods: In 10 bovine rib bones, 4 implant osteotomies with peri-implant bone defects of various widths were prepared: i) no defect (D0), ii) a 2-mm-wide defect (D2), iii) a 4-mm-wide defect (D4), and iv) a 8-mm-wide defect (D8). The height of all defects was 10 mm. Implant stability quotient (ISQ) values and Periotest values (PTVs) were measured after implant placement and bone cement application. Results: With increasing defect width, decreased ISQs and increased PTVs were observed. Statistically significant differences were found between groups D0 and D8, D0 and D4, and D2 and D8. Prior to bone cement application, inconsistent PTVs were found in group D8 depending on the measurement direction. Bone cement increased the implant stability. Conclusion: Peri-implant bone deficits measuring around 50% of the implant surface compromised implant stability. Clinically, PTVs should be cautiously interpreted in implants with large peri-implant defects due to inconsistent recordings with respect to the measurement direction.
참고문헌 (25)
- Atsumi M, "Methods used to assess implant stability: current status", Int J Oral Maxillofac Implants, 22, pp.743~754 (2007)
- Bischof M, "Implant stability measurement of delayed and immediately loaded implants during healing", Clin Oral Implants Res, 15, pp.529~539 (2004)
- Jung UW, "Secondary stability of microthickness hydroxyapatitecoated dental implants installed without primary stability in dogs", Clin Oral Implants Res, 25, pp.1169~1174 (2014)
- Rea M, "Healing of implants installed in over- or under-prepared sites--an experimental study in dogs", Clin Oral Implants Res, 26, pp.442~446 (2015)
- Lioubavina-Hack N, "Significance of primary stability for osseointegration of dental implants", Clin Oral Implants Res, 17, pp.244~250 (2006)
- Atieh MA, "The prognostic accuracy of resonance frequency analysis in predicting failure risk of immediately restored implants", Clin Oral Implants Res, 25, pp.29~35 (2014)
- Baltayan S, "The predictive value of resonance frequency analysis measurements in the surgical placement and loading of endosseous implants", J Oral Maxillofac Surg, 74, pp.1145~1152 (2016)
- Schulte W, "Periotest to monitor osseointegration and to check the occlusion in oral implantology", J Oral Implantol, 19, pp.23~32 (1993)
- Meredith N, "Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis", Clin Oral Implants Res, 7, pp.261~267 (1996)
- Bornstein MM, "Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values", Clin Implant Dent Relat Res, 11, pp.338~347 (2009)
- Rodrigo D, "Diagnosis of implant stability and its impact on implant survival: a prospective case series study", Clin Oral Implants Res, 21, pp.255~261 (2010)
- Sennerby L, "20 Jahre Erfahrung mit der Resonanzfrequenzanalyse", Implantologie, 21, pp.21~33 (2013)
- Merheb J, "Influence of bony defects on implant stability", Clin Oral Implants Res, 21, pp.919~923 (2010)
- Shin SY, "The effects of defect type and depth, and measurement direction on the implant stability quotient (ISQ) Value", J Oral Implantol (2014)
- 전상호, "The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets", Maxillofacial Plastic Reconstructive Surgery, 40(4), pp.1~6 (2018), 대한악안면성형재건외과학회[DOI]
- Patel S, "Resonance frequency analysis of sinus augmentation by osteotome sinus floor elevation and lateral window technique", J Oral Maxillofac Surg, 73, pp.1920~1925 (2015)
- Jin Hoon Park, "Radiographic Analysis of Instrumented Posterolateral Fusion Mass Using Mixture of Local Autologous Bone and b-TCP (PolyBone^®) in a Lumbar Spinal Fusion Surgery", 대한신경외과학회지, 49(5), pp.267~272 (2011), 대한신경외과학회
- Park JH, "Anterior cervical interbody fusion using polyetheretherketone cage filled with autologous and synthetic bone graft substrates for cervical spondylosis: comparative analysis between PolyBone® and iliac bone", Neurol Med Chir (Tokyo), 53, pp.85~90 (2013)
- Park YH, "Obliteration of temporal dorsal bulla in guinea pigs using different types of calcium phosphate", Int J Pediatr Otorhinolaryngol, 75, pp.1176~1180 (2011)
- Oh JS, "A comparative study of two noninvasive techniques to evaluate implant stability: Periotest and Osstell Mentor", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 107, pp.513~518 (2009)
- Rasmusson L, "Implant stability measurements using resonance frequency analysis in the grafted maxilla: a cross-sectional pilot study", Clin Implant Dent Relat Res, 1, pp.70~74 (1999)
- Sennerby L, "Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications", Periodontol 2000, 47, pp.51~66 (2008)
- 신승윤, "Bone cement grafting increases implant primary stability in circumferential cortical bone defects", Journal of Periodontal & Implant Science, 45(1), pp.30~35 (2015), 대한치주과학회
- Katranji A, "Cortical bone thickness in dentate and edentulous human cadavers", J Periodontol, 78, pp.874~878 (2007)
- Deguchi T, "Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants", Am J Orthod Dentofacial Orthop, 129, pp.721.e7~721.e12 (2006)