본문 바로가기
KERD
논문KCI 등재

Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. Materials and Methods: A systematic search without restrictions was conducted in the following electronic databases: PubMed, Scopus, Web of Science, ScienceDirect, Cochrane, and Open Grey. The hand search was also performed in the main endodontic journals. The eligible studies were submitted to the methodological assessment and data extraction. Results: From 203 abstracts, a total of 10 articles matched the eligible criteria. After reading the full articles, 2 were excluded because of the absence of the heat-treated instruments in the experimental design and 3 due to the lack of a control group using heat-treated instruments without autoclave sterilization. From the 5 included studies, 1 presented a low risk of bias, 3 presented moderate and 1 high risk. It was observed heterogeneous findings in the included studies, with autoclave sterilization cycles increasing, decreasing or not affecting the cyclic fatigue life of heat-treated NiTi instruments. However, the retrieved studies evaluating the cyclic fatigue resistance of endodontic instruments presented different protocols and assessing outcomes, this variability makes the findings less comparable within and also between groups and preclude the establishment of an unbiased scientific evidence base. Conclusions: Considering the little scientific evidence and considerable risk of bias, it is still possible to conclude that autoclave sterilization procedures appear to influence the cyclic fatigue resistance of heat-treated NiTi instruments.

Abstract

Objectives: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. Materials and Methods: A systematic search without restrictions was conducted in the following electronic databases: PubMed, Scopus, Web of Science, ScienceDirect, Cochrane, and Open Grey. The hand search was also performed in the main endodontic journals. The eligible studies were submitted to the methodological assessment and data extraction. Results: From 203 abstracts, a total of 10 articles matched the eligible criteria. After reading the full articles, 2 were excluded because of the absence of the heat-treated instruments in the experimental design and 3 due to the lack of a control group using heat-treated instruments without autoclave sterilization. From the 5 included studies, 1 presented a low risk of bias, 3 presented moderate and 1 high risk. It was observed heterogeneous findings in the included studies, with autoclave sterilization cycles increasing, decreasing or not affecting the cyclic fatigue life of heat-treated NiTi instruments. However, the retrieved studies evaluating the cyclic fatigue resistance of endodontic instruments presented different protocols and assessing outcomes, this variability makes the findings less comparable within and also between groups and preclude the establishment of an unbiased scientific evidence base. Conclusions: Considering the little scientific evidence and considerable risk of bias, it is still possible to conclude that autoclave sterilization procedures appear to influence the cyclic fatigue resistance of heat-treated NiTi instruments.

참고문헌 (40)

  1. Es-Souni M, "On the transformation behaviour, mechanical properties and biocompatibility of two niti-based shape memory alloys: NiTi42 and NiTi42Cu7", Biomaterials, 22, pp.2153~2161 (2001)
  2. Abu-Tahun IH, "Microscopic features of fractured fragment of nickel-titanium endodontic instruments by two different modes of torsional loading", Scanning, 2018, pp.9467059~ (2018)
  3. Thompson SA, "An overview of nickel-titanium alloys used in dentistry", Int Endod J, 33, pp.297~310 (2000)
  4. Pedullà E, "Cyclic fatigue resistance of heat-treated nickel-titanium instruments after immersion in sodium hypochlorite and", or sterilization, 2018, pp.44, 648~653
  5. Cheung GS, "Defects in ProTaper S1 instruments after clinical use : fractographic examination", Int Endod J, 38, pp.802~809 (2005)
  6. Peng B, "Defects in ProTaper S1 instruments after clinical use : longitudinal examination", Int Endod J, 38, pp.550~557 (2005)
  7. Plotino G, "Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments", J Endod, 38, pp.222~225 (2012)
  8. Rodrigues RC, "Infection control in retreatment cases : in vivo antibacterial effects of 2 instrumentation systems", J Endod, 41, pp.1600~1605 (2015)
  9. Zhao D, "Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated nickel-titanium instruments", Int Endod J, 49, pp.990~995 (2016)
  10. Bulem UK, "Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and", or sterilization, 2013, pp.21, 505~510
  11. Champa C, "An analysis of cyclic fatigue resistance of reciprocating instruments in different canal curvatures after immersion in sodium hypochlorite and autoclaving : an in vitro study", J Conserv Dent, 20, pp.194~198 (2017)
  12. Taha Özyürek, "The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments", Restorative Dentistry and Endodontics, 42(4), pp.301~308 (2017), 대한치과보존학회
  13. Moher D, "Preferred reporting items for systematic review and meta-analysis protocols(PRISMA-P)2015 statement", Syst Rev, 4, pp.1~ (2015)
  14. Aurélio IL, "Does air particle abrasion affect the flexural strength and phase transformation of Y-TZP? A systematic review and meta-analysis", Dent Mater, 32, pp.827~845 (2016)
  15. Arias A, "Influence of clinical usage of GT and GTX files on cyclic fatigue resistance", Int Endod J, 47, pp.257~263 (2014)
  16. Hilfer PB, "Multiple autoclave cycle effects on cyclic fatigue of nickel-titanium rotary files produced by new manufacturing methods", J Endod, 37, pp.72~74 (2011)
  17. Khabiri M, "The effect of autoclave sterilization on resistance to cyclic fatigue of Hero endodontic file #642(6%)at two artificial curvature", J Dent(Shiraz), 18, pp.277~281 (2017)
  18. Mize SB, "Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments", J Endod, 24, pp.843~847 (1998)
  19. Parashos P, "Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use", J Endod, 30, pp.722~725 (2004)
  20. Peters OA, "Current challenges and concepts in the preparation of root canal systems : a review", J Endod, 30, pp.559~567 (2004)
  21. Plotino G, "A review of cyclic fatigue testing of nickel-titanium rotary instruments", J Endod, 35, pp.1469~1476 (2009)
  22. de Hemptinne F, "In vivo intracanal temperature evolution during endodontic treatment after the injection of room temperature or preheated sodium hypochlorite", J Endod, 41, pp.1112~1115 (2015)
  23. de Vasconcelos RA, "Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature", J Endod, 42, pp.782~787 (2016)
  24. Inan U, "Cyclic fatigue of Reciproc Blue and Reciproc instruments exposed to intracanal temperature in simulated severe apical curvature", Clin Oral Investig, 23, pp.2077~2082 (2019)
  25. Plotino G, "Cyclic fatigue of Reciproc and Reciproc Blue nickel-titanium reciprocating files at different environmental temperatures", J Endod, 44, pp.1549~1552 (2018)
  26. Savage NW, "The use of autoclaves in the dental surgery", Aust Dent J, 40, pp.197~200 (1995)
  27. Viana AC, "Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments", Int Endod J, 39, pp.709~715 (2006)
  28. Zinelis S, "The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 103, pp.843~847 (2007)
  29. Li XF, "The influence of autoclave sterilization on surface characteristics and cyclic fatigue resistance of 3 nickel-titanium rotary instruments", Shanghai Kou Qiang Yi Xue, 24, pp.690~695 (2015)
  30. Shen Y, "Low environmental temperature influences the fatigue resistance of nickel-titanium files", J Endod, 44, pp.626~629 (2018)
  31. Aminsobhani M, "Evaluation of the fractured surface of five endodontic rotary instruments : a metallurgical study", Iran Endod J, 11, pp.286~292 (2016)
  32. Shim KS, "Mechanical and metallurgical properties of various nickel-titanium rotary instruments", BioMed Res Int, 2017, pp.4528601~ (2017)
  33. Iacono F, "Structural analysis of HyFlex EDM instruments", Int Endod J, 50, pp.303~313 (2017)
  34. Shen Y, "Phase transformation behavior and mechanical properties of thermomechanically treated K3XF nickel-titanium instruments", J Endod, 39, pp.919~923 (2013)
  35. Shen Y, "Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments", J Endod, 37, pp.1566~1571 (2011)
  36. Braga LC, "Impact of heat treatments on the fatigue resistance of different rotary nickel-titanium instruments", J Endod, 40, pp.1494~1497 (2014)
  37. Shen Y, "ProFile Vortex and Vortex Blue nickel-titanium rotary instruments after clinical use", J Endod, 41, pp.937~942 (2015)
  38. Tsujimoto M, "Comparison of conventional and new-generation nickel-titanium files in regard to their physical properties", J Endod, 40, pp.1824~1829 (2014)
  39. Shen Y, "ProFile Vortex instruments after clinical use : a metallurgical properties study", J Endod, 38, pp.1613~1617 (2012)
  40. Hieawy A, "Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments", J Endod, 41, pp.1134~1138 (2015)

관련 논문AI추천

The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instrumentsGülşah Uslu, Koray Yılmaz, Taha Özyürek대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제4호Effect of number of uses and sterilization on the instrumented area and resistance of reciprocating instrumentsde Almeida Gomes Fabio, dos Santos Luciane Geanini Pena, Pappen Fernanda Geraldo, Peraça Victor de Ornelas, Souza Erick Miranda, Xavier Samantha Rodrigues대한치과보존학회 · Restorative Dentistry and Endodontics2021 · 제46권 제2호Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro studyHadeer Mostafa El Feky, Khalid Mohammed Ezzat, Marwa Mahmoud Ali Bedier대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제4호Phase transformation temperatures influence the reduction ratio of fatigue resistance of nickel-titanium reciprocating files at body temperature: an in vitro experimental study곽상원, 김현철, Diemer Franck, Georgelin-Gurgel Marie, Lê Sylvie, Naaman Alfred, Nehme Walid, Pedèches Lola대한치과보존학회 · Restorative Dentistry and Endodontics2025 · 제50권 제4호EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS이윤, 금기연, 오소람, 임상민, 황수연대한치과보존학회 · Restorative Dentistry and Endodontics2009 · 제34권 제5호Isolating design variables by assessing the impact of cross-section geometry on the mechanical performance of nickel-titanium rotary instruments: a comparative in vitro studyAlcalde Murilo Priori, Amorim João Vitor Oliveira de, Duarte Marco Antonio Hungaro, Lima Thaine Oliveira, Neto Raimundo Sales de Oliveira, Silva Emmanuel João Nogueira Leal da, Silva Guilherme Ferreira da, Vieira Anne Rafaella Tenório, Vivan Rodrigo Ricci대한치과보존학회 · Restorative Dentistry and Endodontics2025 · 제50권 제3호

이 간행물의 다른 논문 (13건)