내부 응력이 .06 taper ProFile의 피로 파절에 미치는 영향
Effect of internal stress on cyclic fatigue failure in .06 taper ProFile
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. Materials and Methods: Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For cyclic fatigue measurement, time for separation of the rotary NiTi files was recorded. The fractured surfaces were observed by field emission scanning electron microscope (FE-SEM, SU-70, Hitachi). The time for separation was statistically analyzed using two-way ANOVA and post-hoc Scheffe test at 95% level. Results: In .06 taper ProFile size 20, 25, 30, 35and 40, there were statistically significant difference on time for separation between control group and the other groups (p < 0.05). Conclusion: In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files.
Abstract
Objectives: The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. Materials and Methods: Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For cyclic fatigue measurement, time for separation of the rotary NiTi files was recorded. The fractured surfaces were observed by field emission scanning electron microscope (FE-SEM, SU-70, Hitachi). The time for separation was statistically analyzed using two-way ANOVA and post-hoc Scheffe test at 95% level. Results: In .06 taper ProFile size 20, 25, 30, 35and 40, there were statistically significant difference on time for separation between control group and the other groups (p < 0.05). Conclusion: In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files.
참고문헌 (23)
- Walia HM, "An initial investigation of bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
- Ayar LR, "Shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in a variable tip sequence in simulated curved root canals", Int Endod J, 37, pp.593~601 (2004)
- Al-Sudani D, "A comparison of the canal centering ability of ProFile, K3 and RaCe Nickel Titanium rotary systems", J Endod, 32, pp.1198~1201 (2006)
- Canalda-Sahli C, "A comparison of bending and torsional properties of Kfiles manufactured with different metallic alloys", Int Endod J, 29, pp.185~189 (1996)
- Haapasalo M, "Persistent, recurrent, and acquired infection of the root canal system posttreatment", Endod Topics, 6, pp.29~56 (2003)
- Parashos P, "Rotary NiTi instrument fracture and its consequences", J Endod, 32, pp.1031~1043 (2006)
- Sattapan B, "Defects in rotary nickel-titanium files after clinical use", J Endod, 26, pp.161~165 (2000)
- Ullmann CJ, "Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments", J Endod, 31, pp.183~186 (2005)
- Peters OA, "Current challenges and concepts in the preparation of root canal systems: a review", J Endod, 30, pp.559~567 (2004)
- Parashos P, "Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use", J Endod, 30, pp.722~725 (2004)
- 박세희, "근관치료용 전기모터의 회전 안정성 평가", Restorative Dentistry and Endodontics, 35(4), pp.246~256 (2010), 대한치과보존학회
- Berutti E, "Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments", J Endod, 30, pp.228~230 (2004)
- Li UM, "Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests", J Endod, 28, pp.448~451 (2002)
- Schneider SW, "A comparison of canal preparations in straight and curved root canals", Oral Surg Oral Med Oral Pathol, 32, pp.271~275 (1971)
- Plotino G, "A review of cyclic fatigue testing of nickel-titanium rotary instruments", J Endod, 35, pp.1469~1476 (2009)
- Bahia MG, "Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel–titanium wires employed in the manufacture of rotary endodontic instruments", Int Endod J, 38, pp.795~801 (2005)
- Yared G, "An in vitro study of the torsional properties of new and used K3 instruments", Int Endod J, 36, pp.764~769 (2003)
- 이정규, "Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할", Restorative Dentistry and Endodontics, 32(2), pp.130~137 (2007), 대한치과보존학회
- Yared GM, "Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files", Int Endod J, 35, pp.7~12 (2002)
- Yared GM, "Influence of rotational speed, torque and operator’s proficiency on ProFile failures", Int Endod J, 34, pp.47~53 (2001)
- 김태오, "세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구", Restorative Dentistry and Endodontics, 33(4), pp.323~331 (2008), 대한치과보존학회
- Camps JJ, "Machining efficiency of nickel-titanium K-type files in a linear motion", Int Endod J, 28, pp.279~284 (1995)
- Berutti E, "Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile", J Endod, 29, pp.15~19 (2003)