A short-term clinical study of marginal bone level change around microthreaded and platformswitched implants
1
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Purpose: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants. Methods: The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platformswitched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodontology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit. Results: During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery),the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was 0.16±0.08 mm, the latter of which is lower than the previously reported values. Conclusions: This short-term clinical study has demonstrated the successful survival rates of a microthread and platformswitched implant system, and that this system is associated with reduced marginal bone loss.
Abstract
Purpose: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants. Methods: The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platformswitched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodontology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit. Results: During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery),the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was 0.16±0.08 mm, the latter of which is lower than the previously reported values. Conclusions: This short-term clinical study has demonstrated the successful survival rates of a microthread and platformswitched implant system, and that this system is associated with reduced marginal bone loss.
참고문헌 (34)
- Brånemark PI, "Intra-osseous anchorage of dental prostheses. I. Experimental studies", Scand J Plast Reconstr Surg, 3, pp.81~100 (1969)
- Atwood DA, "Some clinical factors related to rate of resorption of residual ridges. 1962", J Prosthet Dent, 86, pp.119~125 (2001)
- Lekholom U, "Patient selection and preparation In Tissue-integrated prostheses: osseointegration in clinical dentistry", pp.199~220 (1985), Quintessence
- Ahlqvist J, "Osseointegrated implants in edentulous jaws: a 2-year longitudinal study", Int J Oral Maxillofac Implants, 5, pp.155~163 (1990)
- Albrektsson T, "The long-term efficacy of currently used dental implants: a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
- Berglundh T, "A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years", J Clin Periodontol, 29(3), pp.197~212 (2002)
- Chang M, "Implant supported single-tooth replacements compared to contralateral natural teeth. Crown and soft tissue dimensions", Clin Oral Implants Res, 10, pp.185~194 (1999)
- Lazzara RJ, "Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels", Int J Periodontics Restorative Dent, 26, pp.9~17 (2006)
- Schrotenboer J, "Effect of microthreads and platform switching on crestal bone stress levels: a finite element analysis", J Period, 79, pp.2166~2172 (2008)
- Friberg B, "A new self-tapping Branemark implant: clinical and radiographic evaluation", Int J Oral Maxillofac Implants, 7, pp.80~85 (1992)
- Gonshor A, "A prospective, multicenter, 4-year study of the ACE Surgical resorbable blast media implant", J Oral Implantol, 29, pp.174~180 (2003)
- Buser D, "Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants", Clin Oral Implants Res, 1, pp.33~40 (1990)
- Bragger U, "Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants", Clin Oral Implants Res, 9, pp.218~224 (1998)
- Esposito M, "A 5-year follow-up comparative analysis of the efficacy of various osseointegrated dental implant systems: a systematic review of randomized controlled clinical trials", Int J Oral Maxillofac Implants, 20, pp.557~568 (2005)
- Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
- Guo E, "Mechanical properities of cortical bone and cancellous bone tissue. 2nd ed", pp.1~23 (2001), CRC Press
- Lee DW, "Effect of microthread on the maintenance of marginal bone level: A 3-year prospective study", CLINICAL ORAL IMPLANTS RESEARCH, 18, pp.465~470 (2007), BLACKWELL PUBLISHING
- Oh TJ, "The causes of early implant bone loss: myth or science", J Periodontol, 73, pp.322~333 (2002)
- Jung YC, "A 1-year radiographic evaluation of marginal bone around dental implants", Int J Oral Maxillofac Implants, 11, pp.811~818 (1996)
- Hansson S, "The implant neck: smooth or provided with retention elements. A biomechanical approach", Clin Oral Implants Res, 10, pp.394~405 (1999)
- Abrahamsson I, "Tissue characteristics at microthreaded implants: an experimental study in dogs", Clin Implant Dent Relat Res, 8, pp.107~113 (2006)
- Quirynen M, "Microbial penetration along the implant components of the Branemark system. An in vitro study", Clin Oral Implants Res, 5, pp.239~244 (1994)
- Ericsson I, "Different types of inflammatory reactions in peri-implant soft tissues", J Clin Periodontol, 22, pp.255~261 (1995)
- Waerhaug J, "Subgingival plaque and loss of attachment in periodontosis as evaluated on extracted teeth", J Periodontol, 48, pp.125~130 (1977)
- Hurzeler M, "Peri-implant bone level around implants with platform-switched abutments: preliminary data from a prospective study", J Oral Maxillofac Surg, 65(7), pp.33~39 (2007)
- Lopez-Mari L, "Implant platform switching concept: an updated review", Med Oral Patol Oral Cir Bucal, 14, pp.e450~e454 (2009)
- Kwon HJ, "Influence of the Tooth- and Implant-Side Marginal Bone Level on the Interproximal Papilla Dimension in a Single Implant With a Microthread, Conical Seal, and Platform-Switched Design", Journal Of Periodontology, 80(9), pp.1541~1547 (2009), AMER ACAD PERIODONTOLOGY
- Calandriello R, "Immediate occlusal loading of single lower molars using Branemark System Wide-Platform TiUnite implants: an interim report of a prospective open-ended clinical multicenter study", Clin Implant Dent Relat Res, 5(1), pp.74~80 (2003)
- Glauser R, "Immediate occlusal loading of Branemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study", Clin Implant Dent Relat Res, 5(1), pp.47~56 (2003)
- Vanden Bogaerde L, "Early function of splinted implants in maxillas and posterior mandibles, using Branemark System Tiunite implants: an 18-month prospective clinical multicenter study", Clin Implant Dent Relat Res, 6, pp.121~129 (2004)
- Wennstrom JL, "Implant-supported single-tooth restorations: a 5-year prospective study", J Clin Periodontol, 32, pp.567~574 (2005)
- Adell R, "Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study", Int J Oral Maxillofac Surg, 15, pp.39~52 (1986)
- Siegele D, "Numerical investigations of the influence of implant shape on stress distribution in the jaw bone", Int J Oral Maxillofac Implants, 4, pp.333~340 (1989)
- Hollender L, "Radiographic evaluation of osseointegrated implants of the jaws. Experimental study of the influence of radiographic techniques on the measurement of the relation between the implant and bone", Dentomaxillofac Radiol, 9, pp.91~95 (1980)
