Marginal bony changes in relation to different vertical positions of dental implants
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to radiographically evaluate marginal bony changes in relation to different vertical positions of dental implants. Methods: Two hundred implants placed in 107 patients were examined. The implants were classified by the vertical positions of the fixture-abutment connection (microgap): ‘bone level,’ ‘above bone level,’ or ‘below bone level.’ Marginal bone levels were examined in the radiographs taken immediately after fixture insertion, immediately after second-stage surgery, 6 months after prosthesis insertion, and 1 year after prosthesis insertion. Radiographic evaluation was carried out by measuring the distance between the microgap and the most coronal bone-to-implant contact (BIC). Results: Immediately after fixture insertion, the distance between the microgap and most coronal BIC was 0.06 ± 0.68 mm; at second surgery, 0.43 ± 0.83 mm; 6 months after loading, 1.36 ± 0.56 mm; and 1 year after loading, 1.53 ± 0.51 mm (mean ± SD). All bony changes were statistically significant but the difference between the second surgery and the 6-month loading was greater than between other periods. In the ‘below bone level’ group, the marginal bony change between fixture insertion and 1 year after loading was about 2.25 mm, and in the ‘bone level’ group, 1.47 mm, and in ‘above bone level’ group, 0.89 mm. Therefore,the marginal bony change was smaller than other groups in the ‘above bone level’ group and larger than other groups in the ‘below bone level’ group. Conclusions: Our results demonstrated that marginal bony changes occur during the early phase of healing after implant placement. These changes are dependent on the vertical positions of implants.
Abstract
Purpose: The purpose of this study was to radiographically evaluate marginal bony changes in relation to different vertical positions of dental implants. Methods: Two hundred implants placed in 107 patients were examined. The implants were classified by the vertical positions of the fixture-abutment connection (microgap): ‘bone level,’ ‘above bone level,’ or ‘below bone level.’ Marginal bone levels were examined in the radiographs taken immediately after fixture insertion, immediately after second-stage surgery, 6 months after prosthesis insertion, and 1 year after prosthesis insertion. Radiographic evaluation was carried out by measuring the distance between the microgap and the most coronal bone-to-implant contact (BIC). Results: Immediately after fixture insertion, the distance between the microgap and most coronal BIC was 0.06 ± 0.68 mm; at second surgery, 0.43 ± 0.83 mm; 6 months after loading, 1.36 ± 0.56 mm; and 1 year after loading, 1.53 ± 0.51 mm (mean ± SD). All bony changes were statistically significant but the difference between the second surgery and the 6-month loading was greater than between other periods. In the ‘below bone level’ group, the marginal bony change between fixture insertion and 1 year after loading was about 2.25 mm, and in the ‘bone level’ group, 1.47 mm, and in ‘above bone level’ group, 0.89 mm. Therefore,the marginal bony change was smaller than other groups in the ‘above bone level’ group and larger than other groups in the ‘below bone level’ group. Conclusions: Our results demonstrated that marginal bony changes occur during the early phase of healing after implant placement. These changes are dependent on the vertical positions of implants.
참고문헌 (20)
- Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
- Jemt T, "3-year followup study of early single implant restorations ad modum Branemark", Int J Periodontics Restorative Dent, 10, pp.340~349 (1990)
- Cox JF, "The longitudinal clinical efficacy of osseointegrated dental implants: a 3-year report", Int J Oral Maxillofac Implants, 2, pp.91~100 (1987)
- Albrektsson T, "Consensus report of session V", Proceedings of the 1st European Workshop on Periodontology, pp.365~369 (1993), Quintessence
- Hermann JS, "Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible", J Periodontol, 68, pp.1117~1130 (1997)
- Quirynen M, "Bacterial colonization of the internal part of two-stage implants. An in vivo study", Clin Oral Implants Res, 4, pp.158~161 (1993)
- Persson LG, "Bacterial colonization on internal surfaces of Branemark system implant components", Clin Oral Implants Res, 7, pp.90~95 (1996)
- Tarnow DP, "The effect of inter-implant distance on the height of inter-implant bone crest", J Periodontol, 71, pp.546~549 (2000)
- Bain CA, "installation in the smoking patient", Periodontol 2000, 33, pp.185~193 (2003)
- Hermann JS, "Biologic Width around one- and two-piece titanium implants", Clin Oral Implants Res, 12, pp.559~571 (2001)
- Weber HP, "Comparison of healed tissues adjacent to submerged and non-submerged unloaded titanium dental implants. A histometric study in beagle dogs", Clin Oral Implants Res, 7, pp.11~19 (1996)
- Lee DW, "Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study", Clin Oral Implants Res, 18, pp.465~470 (2007)
- Oh TJ, "The causes of early implant bone loss: myth or science?", J Periodontol, 73, pp.322~333 (2002)
- Wilderman MN, "Histogenesis of repair following osseous surgery", J Periodontol, 41, pp.551~565 (1970)
- Jung YC, "A 1-year radiographic evaluation of marginal bone around dental implants", Int J Oral Maxillofac Implants, 11, pp.811~818 (1996)
- Engquist B, "Marginal bone reaction to oral implants: a prospective comparative study of Astra Tech and Branemark System implants", Clin Oral Implants Res, 13, pp.30~37 (2002)
- Berglundh T, "Dimension of the periimplant mucosa.Biological width revisited", J Clin Periodontol, 23, pp.971~973 (1996)
- Berglundh T, "The soft tissue barrier at implants and teeth", Clin Oral Implants Res, 2, pp.81~90 (1991)
- Abrahamsson I, "Peri-implant tissues at submerged and non-submerged titanium implants", J Clin Periodontol, 26, pp.600~607 (1999)
- Abrahamsson I, "The peri-implant hard and soft tissues at different implant systems.A comparative study in the dog", Clin Oral Implants Res, 7, pp.212~219 (1996)