Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: The aim of this study was to compare straight and tapered implant designs in terms of marginal bone loss, the modified plaque index (mPI), and the modified bleeding index (mBI) for 5 years after functional loading. Methods: Twelve patients were recruited. Two types of implants were placed adjacent to each other: 1 straight implant and 1 tapered implant. Marginal bone loss, mPI, and mBI were measured every year for 5 years after loading. Results: The straight implants showed 0.2±0.4 mm of marginal bone loss at 5 years after loading, while the tapered implants showed 0.2±0.3 mm of marginal bone loss; this difference was not statistically significant (P=0.833). Our analysis also showed no statistically significant differences in mPI (straight implants: 0.3±0.3 vs. tapered implants: 0.2±0.3; P=0.414) or in mBI (straight implants: 0.3±0.4 vs. tapered implants: 0.2±0.3; P=0.317) at 5 years after prosthesis delivery. Conclusions: Straight and tapered implants showed no significant differences with respect to marginal bone loss, mPI, and mBI for 5 years after loading.
Abstract
Purpose: The aim of this study was to compare straight and tapered implant designs in terms of marginal bone loss, the modified plaque index (mPI), and the modified bleeding index (mBI) for 5 years after functional loading. Methods: Twelve patients were recruited. Two types of implants were placed adjacent to each other: 1 straight implant and 1 tapered implant. Marginal bone loss, mPI, and mBI were measured every year for 5 years after loading. Results: The straight implants showed 0.2±0.4 mm of marginal bone loss at 5 years after loading, while the tapered implants showed 0.2±0.3 mm of marginal bone loss; this difference was not statistically significant (P=0.833). Our analysis also showed no statistically significant differences in mPI (straight implants: 0.3±0.3 vs. tapered implants: 0.2±0.3; P=0.414) or in mBI (straight implants: 0.3±0.4 vs. tapered implants: 0.2±0.3; P=0.317) at 5 years after prosthesis delivery. Conclusions: Straight and tapered implants showed no significant differences with respect to marginal bone loss, mPI, and mBI for 5 years after loading.
참고문헌 (38)
- Kim JJ, "Effect of conical configuration of fixture on the maintenance of marginal bone level : preliminary results at 1 year of function", Clin Oral Implants Res, 21, pp.439~444 (2010)
- Quirynen M, "Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system", Clin Oral Implants Res, 3, pp.104~111 (1992)
- Torroella-Saura G, "Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial", Clin Oral Implants Res, 26, pp.240~244 (2015)
- Javed F, "The role of primary stability for successful immediate loading of dental implants. A literature review", J Dent, 38, pp.612~620 (2010)
- Glauser R, "Implants with on oxidized surface placed predominately in soft bone quality and subjected to immediate occlusal loading : results from an 11-year clinical follow-up", Clin Implant Dent Relat Res, 18, pp.429~438 (2016)
- AlFarraj Aldosari A, "The influence of implant geometry and surface composition on bone response", Clin Oral Implants Res, 25, pp.500~505 (2014)
- Waechter J, "Comparison between tapered and cylindrical implants in the posterior regions of the mandible: a prospective, randomized, split-mouth clinical trial focusing on implant stability changes during early healing", Clin Implant Dent Relat Res, 19, pp.733~741 (2017)
- Kadkhodazadeh M, "Radiographic evaluation of marginal bone levels around dental implants with different designs after 1 year", Acta Odontol Scand, 71, pp.92~95 (2013)
- Sargolzaie N, "Evaluation of crestal bone resorption around cylindrical and conical implants following 6 months of loading : a randomized clinical trial", Eur J Dent, 11, pp.317~322 (2017)
- Lee DW, "Effect of microthread on the maintenance of marginal bone level : a 3-year prospective study", Clin Oral Implants Res, 18, pp.465~470 (2007)
- Lang NP, "A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. II. Combined tooth--implant-supported FPDs", Clin Oral Implants Res, 15, pp.643~653 (2004)
- Karoussis IK, "A comprehensive and critical review of dental implant prognosis in periodontally compromised partially edentulous patients", Clin Oral Implants Res, 18, pp.669~679 (2007)
- Armitage GC, "Development of a classification system for periodontal diseases and conditions", Ann Periodontol, 4, pp.1~6 (1999)
- Lee DW, "Dimension of interproximal soft tissue between adjacent implants in two distinctive implant systems", J Periodontol, 77, pp.1080~1084 (2006)
- Mombelli A, "Clinical parameters for the evaluation of dental implants", Periodontol 2000, 4, pp.81~86 (1994)
- Mombelli A, "The microbiota associated with successful or failing osseointegrated titanium implants", Oral Microbiol Immunol, 2, pp.145~151 (1987)
- Wyatt CC, "A computer-assisted measurement technique to assess bone proximal to oral implants on intraoral radiographs", Clin Oral Implants Res, 12, pp.225~229 (2001)
- Brägger U, "Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants", Clin Oral Implants Res, 9, pp.218~224 (1998)
- Noguchi K, "nparLD : an R software package for the nonparametric analysis of longitudinal data in factorial experiments", J Stat Softw, 50, pp.1~23 (2012)
- Chen SY, "A general introduction to adjustment for multiple comparisons", J Thorac Dis, 9, pp.1725~1729 (2017)
- Malevez C, "Marginal bone levels at Brånemark system implants used for single tooth restoration. The influence of implant design and anatomical region", Clin Oral Implants Res, 7, pp.162~169 (1996)
- Nordin T, "The use of a conical fixture design for fixed partial prostheses. A preliminary report", Clin Oral Implants Res, 9, pp.343~347 (1998)
- Wennström JL, "Implant-supported single-tooth restorations : a 5-year prospective study", J Clin Periodontol, 32, pp.567~574 (2005)
- Messias A, "Titanium dental implants with different collar design and surface modifications : a systematic review on survival rates and marginal bone levels", Clin Oral Implants Res, 30, pp.20~48 (2019)
- Hudieb MI, "Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant", J Periodontol, 82, pp.1061~1070 (2011)
- Calvo-Guirado JL, "Peri-implant bone loss clinical and radiographic evaluation around rough neck and microthread implants: a 5-year study", Clin Oral Implants Res, 29, pp.635~643 (2018)
- Hansson S, "Implant-abutment interface : biomechanical study of flat top versus conical", Clin Implant Dent Relat Res, 2, pp.33~41 (2000)
- Schmitt CM, "Performance of conical abutment(Morse Taper)connection implants : a systematic review", J Biomed Mater Res A, 102, pp.552~574 (2014)
- Caricasulo R, "The influence of implant-abutment connection to peri-implant bone loss : a systematic review and meta-analysis", Clin Implant Dent Relat Res, 20, pp.653~664 (2018)
- Laurell L, "Marginal bone level changes at dental implants after 5 years in function : a metaanalysis", Clin Implant Dent Relat Res, 13, pp.19~28 (2011)
- Xiao JR, "The biomechanical analysis of simulating implants in function under osteoporotic jawbone by comparing cylindrical, apical tapered, neck tapered, and expandable type implants : a 3-dimensional finite element analysis", J Oral Maxillofac Surg, 69, pp.e273~81 (2011)
- Isidor F, "Influence of forces on peri-implant bone", Clin Oral Implants Res, 17(Suppl 2), pp.8~18 (2006)
- Kokovic V, "Immediate vs. early loading of SLA implants in the posterior mandible: 5-year results of randomized controlled clinical trial", Clin Oral Implants Res, 25, pp.e114~9 (2014)
- Corbella S, "Clinical evaluation of an implant maintenance protocol for the prevention of peri-implant diseases in patients treated with immediately loaded full-arch rehabilitations", Int J Dent Hyg, 9, pp.216~222 (2011)
- Cardaropoli G, "Peri-implant bone alterations in relation to inter-unit distances. A 3-year retrospective study", Clin Oral Implants Res, 14, pp.430~436 (2003)
- Elian N, "Effect of interimplant distance(2and 3 mm)on the height of interimplant bone crest : a histomorphometric evaluation", J Periodontol, 82, pp.1749~1756 (2011)
- Khayat PG, "Prospective clinical evaluation of 835 multithreaded tapered screw-vent implants : results after two years of functional loading", J Oral Implantol, 33, pp.225~231 (2007)
- Anitua E, "15-year follow-up of short dental implants placed in the partially edentulous patient : Mandible Vs maxilla", Ann Anat, 222, pp.88~93 (2019)