본문 바로가기
KERD
논문KCI 등재

The polymerization efficiency of a bulk-fill composite based on matrix-modification technology

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: To evaluate the polymerization efficiency of a matrix-modified bulk-fill composite, and compare it to a conventional composite which has a similar filler system. The degree of conversion (DC%) and monomer elution were measured over different storage periods. Additionally, fillers' content was examined. Materials and Methods: Cylindrical specimens were prepared, in bulk and incrementally, from Filtek Bulk Fill (B) and Filtek Supreme XTE (S) composites using a Teflon mold, for each test (n = 6). Using attenuated total reflection method of Fourier transformation infrared spectroscopy, DC% was measured after 24 hours, 7 days, and 30 days. Using high-performance liquid chromatography, elution of hydroxyethyl methacrylate, triethylene glycol dimethacrylate, urethane dimethacrylate, and bisphenol-A glycidyl dimethacrylate was measured after 24 hours, 7 days and 30 days. Filler content was examined by scanning electron microscopy (SEM). Data were analyzed using 2-way mixed-model analysis of variance (α = 0.05). Results: There was no significant difference in DC% over different storage periods between B-bulk and S-incremental. Higher monomer elution was detected significantly from S than B. The elution quantity and rate varied significantly over storage periods and between different monomers. SEM images showed differences in fillers' sizes and agglomeration between both materials. Conclusions: Matrix-modified bulk-fill composites could be packed and cured in bulk with polymerization efficiency similar to conventional composites.

Abstract

Objectives: To evaluate the polymerization efficiency of a matrix-modified bulk-fill composite, and compare it to a conventional composite which has a similar filler system. The degree of conversion (DC%) and monomer elution were measured over different storage periods. Additionally, fillers' content was examined. Materials and Methods: Cylindrical specimens were prepared, in bulk and incrementally, from Filtek Bulk Fill (B) and Filtek Supreme XTE (S) composites using a Teflon mold, for each test (n = 6). Using attenuated total reflection method of Fourier transformation infrared spectroscopy, DC% was measured after 24 hours, 7 days, and 30 days. Using high-performance liquid chromatography, elution of hydroxyethyl methacrylate, triethylene glycol dimethacrylate, urethane dimethacrylate, and bisphenol-A glycidyl dimethacrylate was measured after 24 hours, 7 days and 30 days. Filler content was examined by scanning electron microscopy (SEM). Data were analyzed using 2-way mixed-model analysis of variance (α = 0.05). Results: There was no significant difference in DC% over different storage periods between B-bulk and S-incremental. Higher monomer elution was detected significantly from S than B. The elution quantity and rate varied significantly over storage periods and between different monomers. SEM images showed differences in fillers' sizes and agglomeration between both materials. Conclusions: Matrix-modified bulk-fill composites could be packed and cured in bulk with polymerization efficiency similar to conventional composites.

참고문헌 (40)

  1. Sgarbi SC, "Degree of conversion of resin composites light activated by halogen light and led analyzed by ultraviolet spectrometry", Arch Oral Res, 6, pp.223~230 (2010)
  2. Schwengberg S, "In vitro embryotoxicity assessment with dental restorative materials", J Dent, 33, pp.49~55 (2005)
  3. Halvorson RH, "Energy dependent polymerization of resin-based composite", Dent Mater, 18, pp.463~469 (2002)
  4. Cramer NB, "Recent advances and developments in composite dental restorative materials", J Dent Res, 90, pp.402~416 (2011)
  5. Frauscher KE, "Depth of cure and mechanical properties of nano-hybrid resin-based composites with novel and conventional matrix formulation", Clin Oral Investig, 16, pp.1425~1434 (2012)
  6. Atai M, "Synthesis, characterization, shrinkage and curing kinetics of a new low-shrinkage urethane dimethacrylate monomer for dental applications", Dent Mater, 23, pp.1030~1041 (2007)
  7. Ganster B, "New photocleavable structures. Diacylgermane-based photoinitiators for visible light curing", Macromolecules, 41, pp.2394~2400 (2008)
  8. Kerby RE, "Synthesis and evaluation of modified urethane dimethacrylate resins with reduced water sorption and solubility", Dent Mater, 25, pp.302~313 (2009)
  9. Kloxin CJ, "Covalent adaptable networks: smart, reconfigurable and responsive network systems", Chem Soc Rev, 42, pp.7161~7173 (2013)
  10. Bowman CN, "Covalent adaptable networks : reversible bond structures incorporated in polymer networks", Angew Chem Int Ed Engl, 51, pp.4272~4274 (2012)
  11. Rothmund L, "Effect of layer thickness on the elution of bulk-fill composite components", Dent Mater, 33, pp.54~62 (2017)
  12. Alshali RZ, "Long-term sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva", J Dent, 43, pp.1511~1518 (2015)
  13. Orłowski M, "Evaluation of marginal integrity of four bulk-fill dental composite materials : in vitro study", Sci World J, 2015, pp.701262~ (2015)
  14. Ilie N, "Influence of various irradiation processes on the mechanical properties and polymerisation kinetics of bulk-fill resin based composites", J Dent, 41, pp.695~702 (2013)
  15. Lempel E, "Degree of conversion and BisGMA, TEGDMA, UDMA elution from flowable bulk fill composites", Int J Mol Sci, 17, pp.732~ (2016)
  16. Li X, "Curing profile of bulk-fill resin-based composites", J Dent, 43, pp.664~672 (2015)
  17. Par M, "Effect of temperature on post-cure polymerization of bulk-fill composites", J Dent, 42, pp.1255~1260 (2014)
  18. Alshali RZ, "Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals", Dent Mater, 29, pp.e213~e217 (2013)
  19. Leprince JG, "New insight into the"depth of cure"of dimethacrylate-based dental composites", Dent Mater, 28, pp.512~520 (2012)
  20. Zorzin J, "Bulk-fill resin composites : polymerization properties and extended light curing", Dent Mater, 31, pp.293~301 (2015)
  21. Durner J, "Correlation of the degree of conversion with the amount of elutable substances in nano-hybrid dental composites", Dent Mater, 28, pp.1146~1153 (2012)
  22. Czasch P, "In vitro comparison of mechanical properties and degree of cure of bulk fill composites", Clin Oral Investig, 17, pp.227~235 (2013)
  23. Sharma S, "Comparative evaluation of residual monomer content and polymerization shrinkage of a packable composite and an ormocer", J Conserv Dent, 15, pp.161~165 (2012)
  24. Leprince JG, "Progress in dimethacrylate-based dental composite technology and curing efficiency", Dent Mater, 29, pp.139~156 (2013)
  25. Ferracane JL, "Elution of leachable components from composites", J Oral Rehabil, 21, pp.441~452 (1994)
  26. Peutzfeldt A, "Resin composites in dentistry : the monomer systems", Eur J Oral Sci, 105, pp.97~116 (1997)
  27. Shawkat ES, "Oxygen inhibition and incremental layer bond strengths of resin composites", Dent Mater, 25, pp.1338~1346 (2009)
  28. Lempel E, "Quantification of conversion degree and monomer elution from dental composite using HPLC and micro-Raman spectroscopy", Chromatographia, 77, pp.1137~1144 (2014)
  29. Schneider LF, "Effect of time and polymerization cycle on the degree of conversion of a resin composite", Oper Dent, 31, pp.489~495 (2006)
  30. Anseth KS, "Biopolymers II. Advances in polymer science", pp.177~217 (1995), Springer
  31. Miletic V, "Quantification of monomer elution and carbon-carbon double bonds in dental adhesive systems using HPLC and micro-Raman spectroscopy", J Dent, 37, pp.177~184 (2009)
  32. Manojlovic D, "Monomer elution from nanohybrid and ormocer-based composites cured with different light sources", Dent Mater, 27, pp.371~378 (2011)
  33. "Recommendations for chemistry data for indirect food additives petitions", United States Food and Drug Administration, Centre for Food Safety and Applied Nutrition USA, ~ (1988)
  34. Van Landuyt KL, "How much do resin-based dental materials release? A meta-analytical approach", Dent Mater, 27, pp.723~747 (2011)
  35. Tanaka K, "Residual monomers(TEGDMA and Bis-GMA)of a set visible-light-cured dental composite resin when immersed in water", J Oral Rehabil, 18, pp.353~362 (1991)
  36. Polydorou O, "Elution of monomers from two conventional dental composite materials", Dent Mater, 23, pp.1535~1541 (2007)
  37. Michelsen VB, "Quantitative analysis of TEGDMA and HEMA eluted into saliva from two dental composites by use of GC", MS and tailor-made internal standards, 2008, pp.24, 724~731
  38. Michelsen VB, "Quantification of organic eluates from polymerized resin-based dental restorative materials by use of GC", MS, 2007, pp.850, 83~91
  39. Sideridou I, "Study of water sorption, solubility and modulus of elasticity of light-cured dimethacrylate-based dental resins", Biomaterials, 24, pp.655~665 (2003)
  40. Michelsen VB, "Identification of organic eluates from four polymer-based dental filling materials", Eur J Oral Sci, 111, pp.263~271 (2003)

관련 논문AI추천

Physicochemical characterization of two bulk fill composites at different depthsCuevas-Suárez Carlos Enrique, Francia Alejandro, Grazioli Guillermo, Moraes Rafael Ratto de, Nakanishi Leina대한치과보존학회 · Restorative Dentistry and Endodontics2021 · 제46권 제3호Analysis of temperature change during polymerization according to resin thickness: an in vitro experimental study배꽃별, 오원만, 이빈나, 장훈상, 황윤찬, 황인남, Cho Young-Tae, Noh Eun-Young대한치과보존학회 · Restorative Dentistry and Endodontics2025 · 제50권 제4호The effect of resin thickness on polymerization characteristics of silorane-based composite resin허복, 권용훈, 노형미, 박정길, 손성애대한치과보존학회 · Restorative Dentistry and Endodontics2014 · 제39권 제4호Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology김은지, 이규복, 진명욱대한턱관절교합학회 · 구강회복응용과학지2016 · 제32권 제3호Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites허복, 권용훈, 김은하, 박정길, 손성애, 정경화대한치과보존학회 · Restorative Dentistry and Endodontics2015 · 제40권 제2호Errors in light-emitting diodes positioning when curing bulk fill and incremental composites: impact on properties after agingAlkhubaizi Qoot, Balhaddad Abdulrahman A., Collares Fabrício M., Garcia Isadora M., Ibrahim Maria Salem, Maktabi Haifa, Melo Mary Anne S., Strassler Howard대한치과보존학회 · Restorative Dentistry and Endodontics2021 · 제46권 제4호

이 간행물의 다른 논문 (15건)