The polymerization efficiency of a bulk-fill composite based on matrix-modification technology
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: To evaluate the polymerization efficiency of a matrix-modified bulk-fill composite, and compare it to a conventional composite which has a similar filler system. The degree of conversion (DC%) and monomer elution were measured over different storage periods. Additionally, fillers' content was examined. Materials and Methods: Cylindrical specimens were prepared, in bulk and incrementally, from Filtek Bulk Fill (B) and Filtek Supreme XTE (S) composites using a Teflon mold, for each test (n = 6). Using attenuated total reflection method of Fourier transformation infrared spectroscopy, DC% was measured after 24 hours, 7 days, and 30 days. Using high-performance liquid chromatography, elution of hydroxyethyl methacrylate, triethylene glycol dimethacrylate, urethane dimethacrylate, and bisphenol-A glycidyl dimethacrylate was measured after 24 hours, 7 days and 30 days. Filler content was examined by scanning electron microscopy (SEM). Data were analyzed using 2-way mixed-model analysis of variance (α = 0.05). Results: There was no significant difference in DC% over different storage periods between B-bulk and S-incremental. Higher monomer elution was detected significantly from S than B. The elution quantity and rate varied significantly over storage periods and between different monomers. SEM images showed differences in fillers' sizes and agglomeration between both materials. Conclusions: Matrix-modified bulk-fill composites could be packed and cured in bulk with polymerization efficiency similar to conventional composites.
Abstract
Objectives: To evaluate the polymerization efficiency of a matrix-modified bulk-fill composite, and compare it to a conventional composite which has a similar filler system. The degree of conversion (DC%) and monomer elution were measured over different storage periods. Additionally, fillers' content was examined. Materials and Methods: Cylindrical specimens were prepared, in bulk and incrementally, from Filtek Bulk Fill (B) and Filtek Supreme XTE (S) composites using a Teflon mold, for each test (n = 6). Using attenuated total reflection method of Fourier transformation infrared spectroscopy, DC% was measured after 24 hours, 7 days, and 30 days. Using high-performance liquid chromatography, elution of hydroxyethyl methacrylate, triethylene glycol dimethacrylate, urethane dimethacrylate, and bisphenol-A glycidyl dimethacrylate was measured after 24 hours, 7 days and 30 days. Filler content was examined by scanning electron microscopy (SEM). Data were analyzed using 2-way mixed-model analysis of variance (α = 0.05). Results: There was no significant difference in DC% over different storage periods between B-bulk and S-incremental. Higher monomer elution was detected significantly from S than B. The elution quantity and rate varied significantly over storage periods and between different monomers. SEM images showed differences in fillers' sizes and agglomeration between both materials. Conclusions: Matrix-modified bulk-fill composites could be packed and cured in bulk with polymerization efficiency similar to conventional composites.
참고문헌 (40)
- Sgarbi SC, "Degree of conversion of resin composites light activated by halogen light and led analyzed by ultraviolet spectrometry", Arch Oral Res, 6, pp.223~230 (2010)
- Schwengberg S, "In vitro embryotoxicity assessment with dental restorative materials", J Dent, 33, pp.49~55 (2005)
- Halvorson RH, "Energy dependent polymerization of resin-based composite", Dent Mater, 18, pp.463~469 (2002)
- Cramer NB, "Recent advances and developments in composite dental restorative materials", J Dent Res, 90, pp.402~416 (2011)
- Frauscher KE, "Depth of cure and mechanical properties of nano-hybrid resin-based composites with novel and conventional matrix formulation", Clin Oral Investig, 16, pp.1425~1434 (2012)
- Atai M, "Synthesis, characterization, shrinkage and curing kinetics of a new low-shrinkage urethane dimethacrylate monomer for dental applications", Dent Mater, 23, pp.1030~1041 (2007)
- Ganster B, "New photocleavable structures. Diacylgermane-based photoinitiators for visible light curing", Macromolecules, 41, pp.2394~2400 (2008)
- Kerby RE, "Synthesis and evaluation of modified urethane dimethacrylate resins with reduced water sorption and solubility", Dent Mater, 25, pp.302~313 (2009)
- Kloxin CJ, "Covalent adaptable networks: smart, reconfigurable and responsive network systems", Chem Soc Rev, 42, pp.7161~7173 (2013)
- Bowman CN, "Covalent adaptable networks : reversible bond structures incorporated in polymer networks", Angew Chem Int Ed Engl, 51, pp.4272~4274 (2012)
- Rothmund L, "Effect of layer thickness on the elution of bulk-fill composite components", Dent Mater, 33, pp.54~62 (2017)
- Alshali RZ, "Long-term sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva", J Dent, 43, pp.1511~1518 (2015)
- Orłowski M, "Evaluation of marginal integrity of four bulk-fill dental composite materials : in vitro study", Sci World J, 2015, pp.701262~ (2015)
- Ilie N, "Influence of various irradiation processes on the mechanical properties and polymerisation kinetics of bulk-fill resin based composites", J Dent, 41, pp.695~702 (2013)
- Lempel E, "Degree of conversion and BisGMA, TEGDMA, UDMA elution from flowable bulk fill composites", Int J Mol Sci, 17, pp.732~ (2016)
- Li X, "Curing profile of bulk-fill resin-based composites", J Dent, 43, pp.664~672 (2015)
- Par M, "Effect of temperature on post-cure polymerization of bulk-fill composites", J Dent, 42, pp.1255~1260 (2014)
- Alshali RZ, "Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals", Dent Mater, 29, pp.e213~e217 (2013)
- Leprince JG, "New insight into the"depth of cure"of dimethacrylate-based dental composites", Dent Mater, 28, pp.512~520 (2012)
- Zorzin J, "Bulk-fill resin composites : polymerization properties and extended light curing", Dent Mater, 31, pp.293~301 (2015)
- Durner J, "Correlation of the degree of conversion with the amount of elutable substances in nano-hybrid dental composites", Dent Mater, 28, pp.1146~1153 (2012)
- Czasch P, "In vitro comparison of mechanical properties and degree of cure of bulk fill composites", Clin Oral Investig, 17, pp.227~235 (2013)
- Sharma S, "Comparative evaluation of residual monomer content and polymerization shrinkage of a packable composite and an ormocer", J Conserv Dent, 15, pp.161~165 (2012)
- Leprince JG, "Progress in dimethacrylate-based dental composite technology and curing efficiency", Dent Mater, 29, pp.139~156 (2013)
- Ferracane JL, "Elution of leachable components from composites", J Oral Rehabil, 21, pp.441~452 (1994)
- Peutzfeldt A, "Resin composites in dentistry : the monomer systems", Eur J Oral Sci, 105, pp.97~116 (1997)
- Shawkat ES, "Oxygen inhibition and incremental layer bond strengths of resin composites", Dent Mater, 25, pp.1338~1346 (2009)
- Lempel E, "Quantification of conversion degree and monomer elution from dental composite using HPLC and micro-Raman spectroscopy", Chromatographia, 77, pp.1137~1144 (2014)
- Schneider LF, "Effect of time and polymerization cycle on the degree of conversion of a resin composite", Oper Dent, 31, pp.489~495 (2006)
- Anseth KS, "Biopolymers II. Advances in polymer science", pp.177~217 (1995), Springer
- Miletic V, "Quantification of monomer elution and carbon-carbon double bonds in dental adhesive systems using HPLC and micro-Raman spectroscopy", J Dent, 37, pp.177~184 (2009)
- Manojlovic D, "Monomer elution from nanohybrid and ormocer-based composites cured with different light sources", Dent Mater, 27, pp.371~378 (2011)
- "Recommendations for chemistry data for indirect food additives petitions", United States Food and Drug Administration, Centre for Food Safety and Applied Nutrition USA, ~ (1988)
- Van Landuyt KL, "How much do resin-based dental materials release? A meta-analytical approach", Dent Mater, 27, pp.723~747 (2011)
- Tanaka K, "Residual monomers(TEGDMA and Bis-GMA)of a set visible-light-cured dental composite resin when immersed in water", J Oral Rehabil, 18, pp.353~362 (1991)
- Polydorou O, "Elution of monomers from two conventional dental composite materials", Dent Mater, 23, pp.1535~1541 (2007)
- Michelsen VB, "Quantitative analysis of TEGDMA and HEMA eluted into saliva from two dental composites by use of GC", MS and tailor-made internal standards, 2008, pp.24, 724~731
- Michelsen VB, "Quantification of organic eluates from polymerized resin-based dental restorative materials by use of GC", MS, 2007, pp.850, 83~91
- Sideridou I, "Study of water sorption, solubility and modulus of elasticity of light-cured dimethacrylate-based dental resins", Biomaterials, 24, pp.655~665 (2003)
- Michelsen VB, "Identification of organic eluates from four polymer-based dental filling materials", Eur J Oral Sci, 111, pp.263~271 (2003)