Buckling resistance, torque, and force generation during retreatment with D-RaCe, HyFlex Remover, and Mtwo retreatment files
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This study compared the buckling resistance of 3 nickel-titanium (NiTi) retreatment file systems and the torque/force generated during retreatment. Materials and Methods: The buckling resistance was compared among the D-RaCe (DR2), HyFlex Remover, and Mtwo R25/05 retreatment systems. J-shaped canals within resin blocks were prepared with ProTaper NEXT X3 and obturated by the single-cone technique with AH Plus. After 4 weeks, 4 mm of gutta-percha in the coronal aspect was removed with Gates-Glidden drills. Retreatment was then performed using DR1 (size 30, 10% taper) followed by DR2 (size 25, 4% taper), HyFlex Remover (size 30, 7% taper), or Mtrwo R25/05 (size 25, 5% taper) (15 specimens in each group). Further apical preparation was performed with WaveOne Gold Primary. The clockwise torque and upward force generated during retreatment were recorded. After retreatment, resin blocks were examined using stereomicroscopy, and the percentage of residual filling material in the canal area was calculated. Data were analyzed using 1-way analysis of variance with the Tukey test. Results: The HyFlex Remover files exhibited the greatest buckling resistance (p < 0.05), followed by the Mtwo R25/05. The HyFlex Remover and Mtwo R25/05 files generated the highest maximum clockwise torque and upward force, respectively (p < 0.05). The DR1 and DR2 files generated the least upward force and torque (p < 0.05). The percentage of residual filling material after retreatment was not significantly different between file systems (p > 0.05). Conclusions: NiTi retreatment instruments with higher buckling resistance generated greater clockwise torque and upward force.
Abstract
Objectives: This study compared the buckling resistance of 3 nickel-titanium (NiTi) retreatment file systems and the torque/force generated during retreatment. Materials and Methods: The buckling resistance was compared among the D-RaCe (DR2), HyFlex Remover, and Mtwo R25/05 retreatment systems. J-shaped canals within resin blocks were prepared with ProTaper NEXT X3 and obturated by the single-cone technique with AH Plus. After 4 weeks, 4 mm of gutta-percha in the coronal aspect was removed with Gates-Glidden drills. Retreatment was then performed using DR1 (size 30, 10% taper) followed by DR2 (size 25, 4% taper), HyFlex Remover (size 30, 7% taper), or Mtrwo R25/05 (size 25, 5% taper) (15 specimens in each group). Further apical preparation was performed with WaveOne Gold Primary. The clockwise torque and upward force generated during retreatment were recorded. After retreatment, resin blocks were examined using stereomicroscopy, and the percentage of residual filling material in the canal area was calculated. Data were analyzed using 1-way analysis of variance with the Tukey test. Results: The HyFlex Remover files exhibited the greatest buckling resistance (p < 0.05), followed by the Mtwo R25/05. The HyFlex Remover and Mtwo R25/05 files generated the highest maximum clockwise torque and upward force, respectively (p < 0.05). The DR1 and DR2 files generated the least upward force and torque (p < 0.05). The percentage of residual filling material after retreatment was not significantly different between file systems (p > 0.05). Conclusions: NiTi retreatment instruments with higher buckling resistance generated greater clockwise torque and upward force.
참고문헌 (24)
- Karamifar K, "Cleanliness of canal walls following gutta-percha removal with hand files, RaCe and RaCe plus XP-Endo Finisher instruments: a photographic in vitro analysis", Iran Endod J, 12, pp.242~247 (2017)
- Topçuoğlu HS, "Evaluation of debris extruded apically during the removal of root canal filling material using ProTaper, D-RaCe, and R-Endo rotary nickel-titanium retreatment instruments and hand files", J Endod, 40, pp.2066~2069 (2014)
- Beer FP, "Mechanics of materials(in SI units)" (2004), McGraw-Hill Education
- Thompson SA, "An overview of nickel-titanium alloys used in dentistry", Int Endod J, 33, pp.297~310 (2000)
- Zupanc J, "New thermomechanically treated NiTi alloys-a review", Int Endod J, 51, pp.1088~1103 (2018)
- Rödig T, "Efficacy of D-RaCe and ProTaper Universal Retreatment NiTi instruments and hand files in removing gutta-percha from curved root canals-a micro-computed tomography study", Int Endod J, 45, pp.580~589 (2012)
- Garg A, "Comparison of time required by D-RaCe, R-Endo and Mtwo instruments for retreatment: an in vitro study", J Clin Diagn Res, 9, pp.ZC47~ZC49 (2015)
- Staffoli S, "Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel-titanium rotary instrument", Odontology, 107, pp.301~307 (2019)
- Kwak SW, "Torque generation of the endodontic instruments : a narrative review", Materials(Basel), 15, pp.664~ (2022)
- Ha JH, "‘Screw-in’ tendency of rotary nickel-titanium files due to design geometry", Int Endod J, 48, pp.666~672 (2015)
- 하정홍, "Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals", Restorative Dentistry and Endodontics, 37(4), pp.215~219 (2012), 대한치과보존학회[DOI]
- Yilmaz A, "Evaluation of dentin defect formation during retreatment with hand and rotary instruments : a micro-CT study", Scanning, 2017, pp.4868603~ (2017)
- Htun PH, "Comparison of torque, force generation and canal shaping ability between manual and nickel-titanium glide path instruments in rotary and optimum glide path motion", Odontology, 108, pp.188~193 (2020)
- Lopes HP, "Mechanical behavior of pathfinding endodontic instruments", J Endod, 38, pp.1417~1421 (2012)
- "FKG Dentaire: D-Race" (2010)[URL]
- "Coltene: HyFlex Remover" (2019)[URL]
- "VDW: VDW dental Mtwo user brochure" (2015)[URL]
- Fukumori Y, "Comparative analysis of mechanical properties of differently tapered nickeltitanium endodontic rotary instruments", Dent Mater J, 37, pp.667~674 (2018)
- Kwak SW, "Comparison of in vitro torque generation during instrumentation with adaptive versus continuous movement", J Endod, 45, pp.803~807 (2019)
- Lopes WS, "Bending, buckling and torsional resistance of rotary and reciprocating glide path instruments", Int Endod J, 53, pp.1689~1695 (2020)
- Oh S, "Mechanical properties and torque", force generation of XP-Endo Shaper, Trunatomy, Spring Endo File, and Spring Endo heated finish file, part 1, 2022, pp.12, 10393~
- Hülsmann M, "Shaping and filling root canals during root canal re-treatment", Endod Topics, 19, pp.74~124 (2008)
- Piazza B, "The Influence of humidity on intra-tubular penetration and bond strength of AH Plus and MTA Fillapex : an in vitro study", Eur Endod J, 3, pp.48~54 (2017)
- Wiesse PE, "Effect of ultrasonic and sonic activation of root canal sealers on the push-out bond strength and interfacial adaptation to root canal dentine", Int Endod J, 51, pp.102~111 (2018)
