본문 바로가기
KERD
논문KCI 등재

In vitro evaluation of prosthesis-level implant stability using ‘BracketPeg’

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: A small magnetic peg, named “BracketPeg,” has been developed as an attachment magnet for implant prostheses. This study aimed to determine the feasibility of measuring implant stability at the prosthesis level, evaluate the reliability and accuracy of BracketPeg, and examine the consistency of measurements obtained using other devices for damping capacity assessment (DCA) and resonance frequency analysis (RFA). Methods: Forty implants were installed into artificial bone blocks, with each block representing 1 of 4 different diameters (3.5, 4.0, 4.5, and 5.5 mm; 10 implants per diameter). Each implant was paired with a customized zirconia prosthesis that matched the implant diameter. Implant stability was measured at both the fixture and prosthesis levels using Anycheck™ (Neobiotech) for DCA and Osstell™ Beacon (W&H) and ChecQ™ (Dentis) for RFA. To obtain prosthesis-level measurements using RFA devices, BracketPeg was attached to the coronal, middle, and apical thirds of the prosthesis to evaluate implant stability. Results: The implant stability quotient (ISQ) was significantly lower at the prosthesis level than at the fixture level (P<0.001), reflecting the impact of the increased mass and size of the prosthesis. RFA values varied depending on the position of BracketPeg, with lower stability values observed at the coronal position than at the apical position. The 2 RFA devices demonstrated reasonable agreement between ISQ measurements, with a mean difference of −0.58 (95% confidence interval: ±0.31). Conclusions: BracketPeg provides reliable and consistent implant stability measurements at the prosthesis level compared to other devices, making it a practical and feasible tool for the clinical evaluation of implants.

Abstract

Purpose: A small magnetic peg, named “BracketPeg,” has been developed as an attachment magnet for implant prostheses. This study aimed to determine the feasibility of measuring implant stability at the prosthesis level, evaluate the reliability and accuracy of BracketPeg, and examine the consistency of measurements obtained using other devices for damping capacity assessment (DCA) and resonance frequency analysis (RFA). Methods: Forty implants were installed into artificial bone blocks, with each block representing 1 of 4 different diameters (3.5, 4.0, 4.5, and 5.5 mm; 10 implants per diameter). Each implant was paired with a customized zirconia prosthesis that matched the implant diameter. Implant stability was measured at both the fixture and prosthesis levels using Anycheck™ (Neobiotech) for DCA and Osstell™ Beacon (W&H) and ChecQ™ (Dentis) for RFA. To obtain prosthesis-level measurements using RFA devices, BracketPeg was attached to the coronal, middle, and apical thirds of the prosthesis to evaluate implant stability. Results: The implant stability quotient (ISQ) was significantly lower at the prosthesis level than at the fixture level (P<0.001), reflecting the impact of the increased mass and size of the prosthesis. RFA values varied depending on the position of BracketPeg, with lower stability values observed at the coronal position than at the apical position. The 2 RFA devices demonstrated reasonable agreement between ISQ measurements, with a mean difference of −0.58 (95% confidence interval: ±0.31). Conclusions: BracketPeg provides reliable and consistent implant stability measurements at the prosthesis level compared to other devices, making it a practical and feasible tool for the clinical evaluation of implants.

관련 논문AI추천

Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study구기태, 안정섭, 이용무, 이재현, 이정원, 조현재, 표세욱대한치주과학회 · Journal of Periodontal & Implant Science2020 · 제50권 제1호Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study김명섭, 류재준, 심지석, 이정열, 이한나, Xu Zihan대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제3호Comparative analysis of novel damping capacity analysis devices for assessing implant stability in clinical practiceBo-Ah Lee, Jung-Seok Lee, Su-Bin Hong, Woo-Ri Lee, Young-Taek Kim대한치주과학회 · Journal of Periodontal & Implant Science2025 · 제55권 제6호Effects of Striking and Bone Conditions on Damping Capacity Assessment: An in vitro Study강대영, 신현승, 안현성, 조인우대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2023 · 제27권 제2호In vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material곽무성, 김석규대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제4호The reliability of Anycheck device related to healing abutment diameter박진홍, 신상완, 신요한, 심지석, 이동훈, 이정열대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제2호

이 간행물의 다른 논문 (6건)