본문 바로가기
KERD
논문KCI 등재

The evaluation of implant stability measured by resonance frequency analysis in different bone types

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: Bone density seems to be an important factor affecting implant stability. The relationship between bone density and primary and secondary stability remains under debate. The aim of this study was to compare primary and secondary stability measured by resonance frequency analysis (RFA) between different bone types and to compare implant stability at different time points during 3 months of follow-up. Materials and Methods: Our study included 65 implants (BioHorizons Implant Systems) with 3.8 or 4.6 mm diameter and 9 or 10.5 mm length in 59 patients. Bone quality was assessed by Lekholm–Zarb classification. After implant insertion, stability was measured by an Osstell device using RFA at three follow-up visits (immediately, 1 month, and 3 months after implant insertion). ANOVA test was used to compare primary and secondary stability between different bone types and between the three time points for each density type. Results: There were 9 patients in type I, 18 patients in type II, 20 patients in type III, and 12 patients in type IV. Three implants failed, 1 in type I and 2 in type IV. Stability values decreased in the first month but increased during the following two months in all bone types. Statistical analysis showed no significant difference between RFA values of different bone types at each follow-up or between stability values of each bone type at different time points. Conclusion: According to our results, implant stability was not affected by bone density. It is difficult to reach a certain conclusion about the effect of bone density on implant stability as stability is affected by numerous factors.

Abstract

Objectives: Bone density seems to be an important factor affecting implant stability. The relationship between bone density and primary and secondary stability remains under debate. The aim of this study was to compare primary and secondary stability measured by resonance frequency analysis (RFA) between different bone types and to compare implant stability at different time points during 3 months of follow-up. Materials and Methods: Our study included 65 implants (BioHorizons Implant Systems) with 3.8 or 4.6 mm diameter and 9 or 10.5 mm length in 59 patients. Bone quality was assessed by Lekholm–Zarb classification. After implant insertion, stability was measured by an Osstell device using RFA at three follow-up visits (immediately, 1 month, and 3 months after implant insertion). ANOVA test was used to compare primary and secondary stability between different bone types and between the three time points for each density type. Results: There were 9 patients in type I, 18 patients in type II, 20 patients in type III, and 12 patients in type IV. Three implants failed, 1 in type I and 2 in type IV. Stability values decreased in the first month but increased during the following two months in all bone types. Statistical analysis showed no significant difference between RFA values of different bone types at each follow-up or between stability values of each bone type at different time points. Conclusion: According to our results, implant stability was not affected by bone density. It is difficult to reach a certain conclusion about the effect of bone density on implant stability as stability is affected by numerous factors.

참고문헌 (26)

  1. Farré-Pagés N, "Relation between bone density and primary implant stability", Med Oral Patol Oral Cir Bucal, 16, pp.e62~e67 (2011)
  2. Beer A, "Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible", Clin Oral Implants Res, 14, pp.616~620 (2003)
  3. Ekfeldt A, "A retrospective analysis of factors associated with multiple implant failures in maxillae", Clin Oral Implants Res, 12, pp.462~467 (2001)
  4. 박수원, "임플란트 식립 부위의 골밀도 평가에 관한 연구", 대한구강악안면외과학회지, 36(5), pp.417~422 (2010), 대한구강악안면외과학회
  5. Turkyilmaz I, "Bone density assessments of oral implant sites using computerized tomography", J Oral Rehabil, 34, pp.267~272 (2007)
  6. Ribeiro-Rotta RF, "Ambiguity in bone tissue characteristics as presented in studies on dental implant planning and placement : a systematic review", Clin Oral Implants Res, 22, pp.789~801 (2011)
  7. Turkyilmaz I, "Influence of bone density on implant stability parameters and implant success : a retrospective clinical study", BMC Oral Health, 8, pp.32~ (2008)
  8. Albrektsson T, "Osseointegrated titanium implants. Requirements for ensuring a longlasting, direct bone-to-implant anchorage in man", Acta Orthop Scand, 52, pp.155~170 (1981)
  9. Szmukler-Moncler S, "Timing of loading and effect of micromotion on bone-dental implant interface : review of experimental literature", J Biomed Mater Res, 43, pp.192~203 (1998)
  10. Makary C, "Implant primary stability determined by resonance frequency analysis : correlation with insertion torque, histologic bone volume, and torsional stability at 6 weeks", Implant Dent, 21, pp.474~480 (2012)
  11. Coutant JC, "Assessment of the correlation between implant stability and bone density by computed tomography and resonance frequency analysis in fresh cadavers", Int J Oral Maxillofac Implants, 29, pp.1264~1270 (2014)
  12. Kahraman S, "Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of selftapping dental implants", J Oral Rehabil, 36, pp.755~761 (2009)
  13. Atsumi M, "Methods used to assess implant stability : current status", Int J Oral Maxillofac Implants, 22, pp.743~754 (2007)
  14. Sennerby L, "Implant stability measurements using resonance frequency analysis : biological and biomechanical aspects and clinical implications", Periodontol 2000, 47, pp.51~66 (2008)
  15. Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
  16. Kavita GP, "Clinical evaluation of primary stability and osseointegration of endosseous root form implants of different dimensions using periotest", Indian J Appl Res, 3, pp.281~283 (2013)
  17. Simunek A, "Development of implant stability during early healing of immediately loaded implants", Int J Oral Maxillofac Implants, 27, pp.619~627 (2012)
  18. Han J, "Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration:II. Implant surface modifications and implant diameter", Clin Oral Implants Res, 21, pp.605~611 (2010)
  19. Martinez H, "Optimal implant stabilization in low density bone", Clin Oral Implants Res, 12, pp.423~432 (2001)
  20. Turkyilmaz I, "Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement", J Oral Rehabil, 33, pp.881~888 (2006)
  21. Ikumi N, "Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement : a clinical study", Int J Oral Maxillofac Implants, 20, pp.253~260 (2005)
  22. Friberg B, "One-year prospective three-center study comparing the outcome of a"soft bone implant"(prototype Mk IV)and the standard Brånemark implant", Clin Implant Dent Relat Res, 5, pp.71~77 (2003)
  23. Miri R, "Relationship and changes of primary and secondary stability in dental implants : a review", Int J Contemp Dent Med Rev, 2017, pp.03011~ (2017)
  24. Geckili O, "A 24-week prospective study comparing the stability of titanium dioxide grit-blasted dental implants with and without fluoride treatment", Int J Oral Maxillofac Implants, 24, pp.684~688 (2009)
  25. Zhou W, "Is the osseointegration of immediately and delayed loaded implants the same? : comparison of the implant stability during a 3-month healing period in a prospective study", Clin Oral Implants Res, 20, pp.1360~1366 (2009)
  26. Degidi M, "Determination of primary stability : a comparison of the surgeon's perception and objective measurements", Int J Oral Maxillofac Implants, 25, pp.558~561 (2010)

관련 논문AI추천

A comparison of the implant stability among various implant systems: clinical study김선종, 김재민, 류재준, 신상완, 한인호대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제1호Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysisIrena Sailer, Kenko Tanaka, Kensuke Yamauchi, Nobuhiro Yoda, Ryosuke Iwama, Shinnosuke Nogami, Tetsu Takahashi대한치주과학회 · Journal of Periodontal & Implant Science2018 · 제48권 제6호Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value곽재영, 김성균, 윤홍기, 이수영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제1호Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design김용건, 이규복대한턱관절교합학회 · 구강회복응용과학지2018 · 제34권 제2호A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis강인호, 김명주, 김창회, 임영준대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제4호Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study김명섭, 류재준, 심지석, 이정열, 이한나, Xu Zihan대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제3호

이 간행물의 다른 논문 (7건)