Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study
2
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
Objectives: In this study, we determined the incidence and pattern of screw loosening in patients who received dental implants. Materials and Methods: Patients who received implants between January 2008 and October 2013 and completed their prosthetic rehabilitation were evaluated for the incidence, frequency, and onset of screw loosening using dental charts and radiographs. The association between each factor and screw loosening was analyzed using the chi-square test and a multivariate analysis with binary logistic regression models (P<0.05). Results: Total 1,928 implants were placed in 837 patients (448 males, 389 females), whose follow-up period after loading varied from 0.25 to 70 months (mean period, 31.5 months). Screw loosening occurred in 7.2% of implants. Most cases occurred less than six months after loading. Among those, 22.3% experienced recurrent screw loosening. Screw loosening was most common in the molar region (8.5%) and frequently associated with an implant diameter of ≥5 mm (14.2%). External implant–abutment connections (8.9%) and screw-retained implant prostheses (10.1%) showed higher incidence of problems than internal implant–abutment connections and cement-retained implants, respectively. Screw loosening was most common in implant prostheses with single crowns (14.0%). Conclusion: Within the limits of the current study, we conclude that the incidence of screw loosening differs significantly according to the position of implant placement, the type of implant and manufacturer, implant diameter, the type of implant–abutment connection, the type of retention in the implant prosthesis, and the type of implant prosthesis.
Abstract
Objectives: In this study, we determined the incidence and pattern of screw loosening in patients who received dental implants. Materials and Methods: Patients who received implants between January 2008 and October 2013 and completed their prosthetic rehabilitation were evaluated for the incidence, frequency, and onset of screw loosening using dental charts and radiographs. The association between each factor and screw loosening was analyzed using the chi-square test and a multivariate analysis with binary logistic regression models (P<0.05). Results: Total 1,928 implants were placed in 837 patients (448 males, 389 females), whose follow-up period after loading varied from 0.25 to 70 months (mean period, 31.5 months). Screw loosening occurred in 7.2% of implants. Most cases occurred less than six months after loading. Among those, 22.3% experienced recurrent screw loosening. Screw loosening was most common in the molar region (8.5%) and frequently associated with an implant diameter of ≥5 mm (14.2%). External implant–abutment connections (8.9%) and screw-retained implant prostheses (10.1%) showed higher incidence of problems than internal implant–abutment connections and cement-retained implants, respectively. Screw loosening was most common in implant prostheses with single crowns (14.0%). Conclusion: Within the limits of the current study, we conclude that the incidence of screw loosening differs significantly according to the position of implant placement, the type of implant and manufacturer, implant diameter, the type of implant–abutment connection, the type of retention in the implant prosthesis, and the type of implant prosthesis.
참고문헌 (42)
- Brånemark PI, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)
- Lekholm U, "Survival of the Brånemark implant in partially edentulous jaws : a 10-year prospective multicenter study", Int J Oral Maxillofac Implants, 14, pp.639~645 (1999)
- Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
- Goodacre CJ, "Clinical complications of osseointegrated implants", J Prosthet Dent, 81, pp.537~552 (1999)
- Calderon PS, "Technical complications with implantsupported dental prostheses", J Oral Sci, 56, pp.179~184 (2014)
- Jemt T, "Osseointegrated implants for single tooth replacement : a 1-year report from a multicenter prospective study", Int J Oral Maxillofac Implants, 6, pp.29~36 (1991)
- Kreissl ME, "Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5years", Clin Oral Implants Res, 18, pp.720~726 (2007)
- Cho SC, "Screw loosening for standard and wide diameter implants in partially edentulous cases : 3-to 7-year longitudinal data", Implant Dent, 13, pp.245~250 (2004)
- McGlumphy EA, "Implant screw mechanics", Dent Clin North Am, 42, pp.71~89 (1998)
- Winkler S, "Implant screw mechanics and the settling effect : overview", J Oral Implantol, 29, pp.242~245 (2003)
- Zarb GA, "The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: problems and complications encountered", J Prosthet Dent, 64, pp.185~194 (1990)
- Carlson B, "Prosthodontic complications in osseointegrated dental implant treatment", Int J Oral Maxillofac Implants, 9, pp.90~94 (1994)
- 김진만, "수종 임플랜트 지대주나사의 반복하중 후나사풀림에 관한 연구", 대한치과보철학회지, 41(4), pp.519~531 (2003), 대한치과보철학회
- Goodacre CJ, "Clinical complications with implants and implant prostheses", J Prosthet Dent, 90, pp.121~132 (2003)
- Cha HS, "Cumulative survival rate and complication rates of single-tooth implant; focused on the coronal fracture of fixture in the internal connection implant", J Oral Rehabil, 40, pp.595~602 (2013)
- Duncan JP, "Prosthodontic complications in a prospective clinical trial of single-stage implants at 36 months", Int J Oral Maxillofac Implants, 18, pp.561~565 (2003)
- Lang LA, "The effect of the use of a countertorque device on the abutment-implant complex", J Prosthet Dent, 81, pp.411~417 (1999)
- Shinogaya T, "Effects of ethnicity, gender and age on clenching force and load distribution", Clin Oral Investig, 5, pp.63~68 (2001)
- Chladek W, "Experimental evaluation of occlusal forces", Acta Bioeng Biomech, 3, pp.25~37 (2001)
- Simon RL, "Single implant-supported molar and premolar crowns : a ten-year retrospective clinical report", J Prosthet Dent, 90, pp.517~521 (2003)
- Eckert SE, "Retrospective review of 1170 endosseous implants placed in partially edentulous jaws", J Prosthet Dent, 79, pp.415~421 (1998)
- Papavasiliou G, "Threedimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function", J Prosthet Dent, 76, pp.633~640 (1996)
- Al Jabbari YS, "Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 1 : characterization of adhesive wear and structure of retaining screws", J Prosthodont, 17, pp.168~180 (2008)
- Siamos G, "Relationship between implant preload and screw loosening on implant-supported prostheses", J Oral Implantol, 28, pp.67~73 (2002)
- Boggan RS, "Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants", J Prosthet Dent, 82, pp.436~440 (1999)
- 신현모, "Influence of the implant-abutment connection design and diameter on the screw joint stability", The Journal of Advanced of Prosthodontics, 6(2), pp.126~132 (2014), 대한치과보철학회[DOI]
- Urdaneta RA, "The effect of increased crown-to-implant ratio on single-tooth lockingtaper implants", Int J Oral Maxillofac Implants, 25, pp.729~743 (2010)
- Maeda Y, "In vitro differences of stress concentrations for internal and external hex implant-abutment connections : a short communication", J Oral Rehabil, 33, pp.75~78 (2006)
- Binon PP, "Implants and components : entering the new millennium", Int J Oral Maxillofac Implants, 15, pp.76~94 (2000)
- Piermatti J, "An in vitro analysis of implant screw torque loss with external hex and internal connection implant systems", Implant Dent, 15, pp.427~435 (2006)
- Tsuge T, "Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants", Dent Mater J, 28, pp.373~381 (2009)
- Michalakis KX, "Cement-retained versus screw-retained implant restorations : a critical review", Int J Oral Maxillofac Implants, 18, pp.719~728 (2003)
- Nissan J, "Long-term outcome of cemented versus screw-retained implant-supported partial restorations", Int J Oral Maxillofac Implants, 26, pp.1102~1107 (2011)
- Binon PP, "The effect of implant", abutment hexagonal misfit on screw joint stability, 1996, pp.9, 149~160
- Pietrabissa R, "An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses", Clin Oral Implants Res, 11, pp.448~457 (2000)
- Heckmann SM, "Cement fixation and screw retention : parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures", Clin Oral Implants Res, 15, pp.466~473 (2004)
- Balshi TJ, "A comparative study of one implant versus two replacing a single molar", Int J Oral Maxillofac Implants, 11, pp.372~378 (1996)
- Rangert BR, "Load factor control for implants in the posterior partially edentulous segment", Int J Oral Maxillofac Implants, 12, pp.360~370 (1997)
- Haraldson T, "A 10-year follow-up study of the masticatory system after treatment with osseointegrated implant bridges", Scand J Dent Res, 96, pp.243~252 (1988)
- Davis DM, "Maintenance requirements of implant-supported fixed prostheses opposed by implant-supported fixed prostheses, natural teeth, or complete dentures : a 5-year retrospective study", Int J Prosthodont, 16, pp.521~523 (2003)
- Bakaeen LG, "The effect of implant diameter, restoration design, and occlusal table variations on screw loosening of posterior single-tooth implant restorations", J Oral Implantol, 27, pp.63~72 (2001)
- Sadid-Zadeh R, "Prosthetic failure in implant dentistry", Dent Clin North Am, 59, pp.195~214 (2015)
