The reduction in the assembly accuracy of the implant complex could result from fatigue and micromovement during the functional phases and from the manufacturing process. The long-term functional integrity of implant prostheses can be ensured by accurate fit of the interfaces between the assemblies from a biomechanical perspective. A singleimplant restoration on the mandibular left first molar was removed after a 5-year functional period due to mobility, which was diagnosed as abutment screw loosening. The superstructure could not be retrieved, despite exceeding the torque value recommended by the manufacturer; therefore, the restoration was unscrewed and removed. The retrieved restoration, particularly the configuration of the abutment-gold cylinder and abutment-retaining screw interfaces, was analyzed with scanning electron microscopy. Moreover, the assembly accuracy of the old and new assemblies was compared. In the new specimen, a relatively an even linear gap was found between the threads of the abutment and screw and no vertical marginal gaps were found at the abutment-cylinder interface, wherein the horizontal and vertical contacts were incomplete. In the old specimen, an irregular pattern of screw-thread engagement, an irregular linear space at the abutment-cylinder interface, a partially worn-out screw configuration and remnants of the screw in the interface were observed.

Abstract

The reduction in the assembly accuracy of the implant complex could result from fatigue and micromovement during the functional phases and from the manufacturing process. The long-term functional integrity of implant prostheses can be ensured by accurate fit of the interfaces between the assemblies from a biomechanical perspective. A singleimplant restoration on the mandibular left first molar was removed after a 5-year functional period due to mobility, which was diagnosed as abutment screw loosening. The superstructure could not be retrieved, despite exceeding the torque value recommended by the manufacturer; therefore, the restoration was unscrewed and removed. The retrieved restoration, particularly the configuration of the abutment-gold cylinder and abutment-retaining screw interfaces, was analyzed with scanning electron microscopy. Moreover, the assembly accuracy of the old and new assemblies was compared. In the new specimen, a relatively an even linear gap was found between the threads of the abutment and screw and no vertical marginal gaps were found at the abutment-cylinder interface, wherein the horizontal and vertical contacts were incomplete. In the old specimen, an irregular pattern of screw-thread engagement, an irregular linear space at the abutment-cylinder interface, a partially worn-out screw configuration and remnants of the screw in the interface were observed.

참고문헌 (14)

  1. Gil FJ, "Implant-abutment connections : influence of the design on the microgap and their fatigue and fracture behavior of dental implants", J Mater Sci Mater Med, 25, pp.1825~1830 (2014)
  2. Imakita C, "Failure analysis of an abutment fracture on single implant restoration", Implant Dent, 22, pp.326~331 (2013)
  3. Steinebrunner L, "Implant-abutment interface design affects fatigue and fracture strength of implants", Clin Oral Implants Res, 19, pp.1276~1284 (2008)
  4. Coelho AL, "Crosssectional analysis of the implant-abutment interface", J Oral Rehabil, 34, pp.508~516 (2007)
  5. Kano SC, "A classification system to measure the implant-abutment microgap", Int J Oral Maxillofac Implants, 22, pp.879~885 (2007)
  6. Raoofi S, "Comparison of the effect of three abutment-implant connections on stress distribution at the internal surface of dental implants : a finite element analysis", J Dent Res Dent Clin Dent Prospects, 7, pp.132~139 (2013)
  7. Imam AY, "Implant-abutment interface : a comparison of the ultimate force to failure among narrow-diameter implant systems", J Prosthet Dent, 112, pp.136~142 (2014)
  8. "ISO 14801:2007. Dentistry - Implants - Dynamic fatigue test for endosseous dental implants", International Standard Organization, ~ (2007)
  9. Jung RE, "A systematic review of the 5-year survival and complication rates of implant-supported single crowns", Clin Oral Implants Res, 19, pp.119~130 (2008)
  10. Jemt T, "3-year followup study of early single implant restorations ad modum Branemark", Int J Periodontics Restorative Dent, 10, pp.340~349 (1990)
  11. Huang Y, "Mechanism of and factors associated with the loosening of the implant abutment screw : A review", J Esthet Restor Dent, 31, pp.338~345 (2019)
  12. Binon PP, "The effect of eliminating implant", abutment rotational misfit on screw joint stability, 1996, pp.9, 511~519
  13. Vigolo P, "An in vitro evaluation of titanium, zirconia, and alumina procera abutments with hexagonal connection", Int J Oral Maxillofac Implants, 21, pp.575~580 (2006)
  14. Lang LA, "Evaluation of the precision of fit between the Procera custom abutment and various implant systems", Int J Oral Maxillofac Implants, 18, pp.652~658 (2003)

관련 논문AI추천

Screw loosening and changes in removal torque relative to abutment screw length in a dental implant with external abutment connection after oblique cyclic loading이주희, 차현석대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제6호Rotational tolerances of a titanium abutment in the as-received condition and after screw tightening in a conical implant connectionGiuseppe Troiano, Khrystyna Zhurakivska, Luigi Laino, Rosario Prisco대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제6호Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective studyHye-Won Cho, Ji-Hye Jung, Ki-Young Lee, Kyung-Hwan Kwon, Kyung Su Shin, Yu-Lee Kim대한구강악안면외과학회 · 대한구강악안면외과학회지2020 · 제46권 제2호Pull-off resistance of a screwless implant-abutment connection and surface evaluation after cyclic loadingAhmed Othman, Constantin von See, Gergo Mitov, Richard Mosch, Vasilios Alevizakos대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제3호Clinical and scanning electron microscopic analysis of fractured dental implants: a retrospective clinical analysis권경환, Eun-Ja Kim, Jae-Min Lee, Jae-Won Cha, Kyu-Bong Sim대한구강악안면외과학회 · 대한구강악안면외과학회지2012 · 제38권 제6호Influence of internal connection length on screw loosening in internal connection implants김선재, 김성태, 김지선, 김현철, 문홍석, 박영범, 이재훈, 최현민대한치과보철학회 · 대한치과보철학회지2017 · 제55권 제3호

이 간행물의 다른 논문 (4건)