The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: The aim of this study was to report the long-term outcome and the failure mechanism of cementless total hip arthroplasty (THA) using hydroxyapatite (HA)-coated acetabular cup. Materials and Methods: From January 1992 to May 1994, a total of 123 consecutive cementless primary THAs were performed using a HA-coated acetabular cup with metal-on-polyethylene articulation. We retrospectively evaluated 66 hips available for follow-up at a mean 18.3 years (range, 10.4-23.6 years). The survival analysis was performed by the Kaplan-Meier method. We defined end point as any failure that required a reoperation of acetabular component. Results: Thirty-nine of 66 hips (59.1%) were defined as a failure for progressive acetabular osteolysis or aseptic loosening of the cup. Acetabular osteolysis was observed in 47 hips (71.2%) and 33 hips (50.0%) were revised because of cup loosening. The Kaplan-Meier method showed the survival rate of the acetabular cup to be 46.3% at 15 years and 34.8% at 20 years for any failure that required a reoperation of acetabular component. Conclusion: The long-term survival rate of THA using HA-coated acetabular cup was unsatisfactory, and it was attributed to vulnerable property of HA coating and progressive osteolysis.

Abstract

Purpose: The aim of this study was to report the long-term outcome and the failure mechanism of cementless total hip arthroplasty (THA) using hydroxyapatite (HA)-coated acetabular cup. Materials and Methods: From January 1992 to May 1994, a total of 123 consecutive cementless primary THAs were performed using a HA-coated acetabular cup with metal-on-polyethylene articulation. We retrospectively evaluated 66 hips available for follow-up at a mean 18.3 years (range, 10.4-23.6 years). The survival analysis was performed by the Kaplan-Meier method. We defined end point as any failure that required a reoperation of acetabular component. Results: Thirty-nine of 66 hips (59.1%) were defined as a failure for progressive acetabular osteolysis or aseptic loosening of the cup. Acetabular osteolysis was observed in 47 hips (71.2%) and 33 hips (50.0%) were revised because of cup loosening. The Kaplan-Meier method showed the survival rate of the acetabular cup to be 46.3% at 15 years and 34.8% at 20 years for any failure that required a reoperation of acetabular component. Conclusion: The long-term survival rate of THA using HA-coated acetabular cup was unsatisfactory, and it was attributed to vulnerable property of HA coating and progressive osteolysis.

참고문헌 (32)

  1. Capello WN, "Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues", Clin Orthop Relat Res, (355), pp.200~211 (1998)
  2. Geesink RG, "Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates", Clin Orthop Relat Res, (225), pp.147~170 (1987)
  3. Rossi P, "Short-term results of hydroxyapatite-coated primary total hip arthroplasty", Clin Orthop Relat Res, (310), pp.98~102 (1995)
  4. Tonino AJ, "The hydroxyapatite-ABG hip system:5- to 7-year results from an international multicentre study. The International ABG Study Group", J Arthroplasty, 15, pp.274~282 (2000)
  5. Castoldi F, "Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty", J Arthroplasty, 22, pp.363~368 (2007)
  6. Rogers A, "The ABG hydroxyapatitecoated hip prosthesis : one hundred consecutive operations with average 6-year follow-up", J Arthroplasty, 18, pp.619~625 (2003)
  7. Bidar R, "Longterm results of the ABG-1 hydroxyapatite coated total hip arthroplasty : analysis of 111 cases with a minimum followup of 10 years", Orthop Traumatol Surg Res, 95, pp.579~587 (2009)
  8. Chung YY, "High revision rate of hydroxyapatite-coated ABG-I prosthesis", J Orthop Sci, 14, pp.543~547 (2009)
  9. Coathup MJ, "Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components", Biomaterials, 26, pp.4161~4169 (2005)
  10. Kim SY, "Early failure of hemispheric hydroxyapatite-coated acetabular cups", Clin Orthop Relat Res, 446, pp.233~238 (2006)
  11. Lai KA, "Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of 85 Landos Atoll arthroplasties", J Bone Joint Surg Br, 84, pp.641~646 (2002)
  12. Lazarinis S, "Increased risk of revision of acetabular cups coated with hydroxyapatite", Acta Orthop, 81, pp.53~59 (2010)
  13. Paulsen A, "Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients : findings from the Danish Hip Arthroplasty Registry", Acta Orthop, 78, pp.622~628 (2007)
  14. Stilling M, "Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years", Clin Orthop Relat Res, 467, pp.2872~2879 (2009)
  15. Blacha J, "High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses : 65 hips in 56young patients followed for 5-9 years", Acta Orthop Scand, 75, pp.276~282 (2004)
  16. Delank KS, "Increased polyethylene wear after cementless ABG I total hip arthroplasty", Arch Orthop Trauma Surg, 126, pp.509~516 (2006)
  17. Duffy P, "Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty", J Bone Joint Surg Br, 86, pp.34~38 (2004)
  18. Røkkum M, "HA particles can be released from well-fixed HA-coated stems : histopathology of biopsies from 20 hips 2-8 years after implantation", Acta Orthop Scand, 73, pp.298~306 (2002)
  19. Røkkum M, "Tissue reactions adjacent to well-fixed hydroxyapatitecoated acetabular cups. Histopathology of ten specimens retrieved at reoperation after 0.3 to 5.8 years", J Bone Joint Surg Br, 85, pp.440~447 (2003)
  20. Tonino A, "Hydroxyapatite-coated acetabular components. Histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation", J Bone Joint Surg Am, 83(A), pp.817~825 (2001)
  21. Tonino AJ, "Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses", Clin Orthop Relat Res, 467, pp.478~484 (2009)
  22. Harris WH, "Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation", J Bone Joint Surg Am, 51, pp.737~755 (1969)
  23. DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement", Clin Orthop Relat Res, (121), pp.20~32 (1976)
  24. Dorr LD, "Anatomic Porous Replacement hip arthroplasty : first 100 consecutive cases", Semin Arthroplasty, 1, pp.77~86 (1990)
  25. Massin P, "Evaluation of cementless acetabular component migration. An experimental study", J Arthroplasty, 4, pp.245~251 (1989)
  26. Livermore J, "Effect of femoral head size on wear of the polyethylene acetabular component", J Bone Joint Surg Am, 72, pp.518~528 (1990)
  27. Brooker AF, "Ectopic ossification following total hip replacement. Incidence and a method of classification", J Bone Joint Surg Am, 55, pp.1629~1632 (1973)
  28. Cheung KW, "Early failure of smooth hydroxyapatite-coated press-fit acetabular cup--7 years of follow-up", J Arthroplasty, 20, pp.627~631 (2005)
  29. Reikerås O, "Long-term results of HA coated threaded versus HA coated hemispheric press fit cups : 287 hips followed for 11 to 16 years", Arch Orthop Trauma Surg, 126, pp.503~508 (2006)
  30. Oosterbos CJ, "High survival rate of hydroxyapatite-coated hip prostheses : 100consecutive hips followed for 10 years", Acta Orthop Scand, 75, pp.127~133 (2004)
  31. Baker PN, "THA with the ABG I prosthesis at 15 years. Excellent survival with minimal osteolysis", Clin Orthop Relat Res, 468, pp.1855~1861 (2010)
  32. Dumbleton JH, "“The lysis threshold”: an erroneous and perhaps misleading concept? By Harris WH", J Arthroplasty, 18, pp.537~538 (2003)

관련 논문AI추천

이 간행물의 다른 논문 (10건)