A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implantabutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.
Abstract
PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implantabutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.
참고문헌 (17)
- Adell R, "A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws", Int J Oral Maxillofac Implants, 5, pp.347~359 (1990)
- Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
- Henry PJ, "Osseointegrated implants for single-tooth replacement : A prospective 5-year multicenter styudy", Int J Oral Maxillofac Implants, 11, pp.450~455 (1996)
- Lekholm U, "Outcome of oral implant treatment in partially edentulous jaws followed 20 years in clinical function", Clin Oral Implants Res, 8, pp.178~186 (2006)
- Jömeus L, "Loads and designs of screw joints for single crowns supported by osseointegrated implants", Int J Oral Maxillofac Implants, 7, pp.353~359 (1992)
- Kim KS, "Variation in the total lengths of abutment", implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection, 2011, pp.22, 834~839
- Michalakis KX, "Cementretained versus screw-retained implant restorations : A critical review", Int J Oral Maxillofac Implants, 18, pp.719~728 (2003)
- Lewis S, "The"UCLA"abutment", Int J Oral Maxillofac Implants, 3, pp.183~189 (1988)
- Barbosa G, "Prosthetic laboratory influence on the vertical misfit at the implant", UCLA abutment interface, 2007, pp.18(2), 139~143
- Binon P, "The effect of elinimating implant", abutment rotational misfit on screw joint stability, 1996, pp.9, 511~519
- Duncan A, "Effects of thermal treatments on protein adsorption of Co-Cr-Mo ASTM-F75 alloys", J Master Sci;Master Med, 22, pp.1455~1464 (2011)
- Caicedo S, "Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages : A novel mechanism for implant debris reactivity", J Orthop Res, 27, pp.847~854 (2009)
- Proussaefs P, "Evaluation of two Vitallium blade-form implants retrieved after 13 to 21 years of function : A clinical report", J Prosthet Dent, 87, pp.412~417 (2002)
- Teigen K, "Dental implant suprastructures using cobalt-chromium alloy compared with gold alloy framework veneered with ceramic or acrylic resin : a retrospective cohort study up to 18years", Clin Oral Implant Res, 23, pp.853~860 (2012)
- Kenneth J, "Philllips' science of dental materials", pp.336~576 (2003), Charm yun. Co
- Stüker RA, "Preload and torque removal evaluation of three different abutment screw for single standing implant restoration", J Appl Oral Sci, 16(1), pp.55~58 (2008)
- 신현모, "조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향", 대한치과보철학회지, 46(4), pp.396~408 (2008), 대한치과보철학회