세기조절방사선치료의 정도관리
Quality Assurance in Intensity Modulated Radiation Theray
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Intensity-modulated radiation therapy (IMRT) is believed to be one of the best radiation treatment techniques. IMRT is able to deliver fatal doses of radiation to the tumor region with minimal exposure of critical organs. It is essential to have a comprehensive quality assurance program to assure precision and accuracy in treatment, due to the character of IMRT. We applied quality assurance technique to the Eclipse treatment planning system and sought to determine its effectiveness in patient treatment planning. An acrylic phantom, film, and an ionization chamber were used in this study.
Abstract
Intensity-modulated radiation therapy (IMRT) is believed to be one of the best radiation treatment techniques. IMRT is able to deliver fatal doses of radiation to the tumor region with minimal exposure of critical organs. It is essential to have a comprehensive quality assurance program to assure precision and accuracy in treatment, due to the character of IMRT. We applied quality assurance technique to the Eclipse treatment planning system and sought to determine its effectiveness in patient treatment planning. An acrylic phantom, film, and an ionization chamber were used in this study.
참고문헌 (13)
- Mohan R, "The potential and limitations of the inverse radiotherapy technique", Radiotherapy and Oncology, 32(3), pp.232~248 (1994)
- Bortfeld T, "Realization and verification of three-dimensional conformal radiotherapy with modulated fields", Int J Radiat Oncol Biol Phys, 30(4), pp.899~908 (1994)
- Convey DJ, "The generation of intensity modulated fields for conformal radiotheray by dynamic collimation", Phys Med Biol, 37(6), pp.1359~1374 (1992)
- Brahme A, "Solution of an integral equation encountered in radiation therapy", Phys Med Biol, pp.1221~1229 (1982)
- Xing L, "Iterative methods for inverse treatment planning", Phys Med Biol, 41(10), pp.2107~2123 (1996)
- Webb S, "Intensity-Modulated Radiation Therapy" (2001), IoP
- Zhu XR, "Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy by a static multileaf collimator", Med Phys, 29(8), pp.1687~1692 (2002)
- Xia P, "Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system", Med Phys, 29(3), pp.412~423 (2002)
- Low DA, "A technique for the quantitative evaluation of dose distributions", Med Phys, 25(5), pp.656~661 (1998)
- Martens C, "The value of the PinPoint ionchamber for characterization of small field segments used in intensity-modulated radiotheray", Phys Med Biol, 45(9), pp.2519~2530 (2000)
- Dogan N, "Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy", Phys Med Biol, 47(22), pp.4121~4130 (2002)
- 조병철, "세기조절방사선치료(Intensity Modulated Radiation Therapy;IMRT)의 정도보증(Quality Assurance)", Radiation oncology journal, 19(3), pp.275~286 (2001), 대한방사선종양학회
- 김성규, "세기조절방사선치료에서 조사방법이 빔 파라미터 및 선량에 미치는 영향에 대한 연구", 의학물리, 17(2), pp.114~122 (2006), 한국의학물리학회
