In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials
2
조회
0
다운로드
8
인용
0
참고문헌
키워드
초록
PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, 360chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely XTM Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (alpha= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was 4263.8+/-1110.8 N for Group LT, 5070.8+/-1016.4 for Group HT and 6242.0+/-1759.5 N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.
Abstract
PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, 360chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely XTM Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (alpha= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was 4263.8+/-1110.8 N for Group LT, 5070.8+/-1016.4 for Group HT and 6242.0+/-1759.5 N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.
참고문헌 (42)
- Barnfather KD, "Restoration of the upper dental arch using Lava all-ceramic crown and bridgework", Br Dent J, 202, pp.731~735 (2007)
- Coli P, "Precision of a CAD", CAM technique for the production of zirconium dioxide copings, 2004, pp.17, 577~580
- Della Bona A, "Fracture behavior of lithia disilicate- and leucite-based ceramics", Dent Mater, 20, pp.956~962 (2004)
- Devaud V., "Guidelines for success with zirconia ceramics: the changing standards", Pract Proced Aesthet Dent, 17, pp.508~510 (2005)
- Raigrodski AJ, "All-ceramic full-coverage restorations: concepts and guidelines for material selection", Pract Proced Aesthet Dent, 17, pp.249~256 (2005)
- Beuer F, "Digital dentistry: an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204, 505~511
- Luthardt RG, "CAD", CAM-machining effects on Y-TZP zirconia, 2004, pp.20, 655~662
- Tinschert J, "Status of current CAD", CAM technology in dental medicine, 2004, pp.7, 25~45
- Tinschert J, "Fracture resistance of lithium disilicate-, alumina-, and zirconiabased three-unit fixed partial dentures: a laboratory study", Int J Prosthodont, 14, pp.231~238 (2001)
- Vult von Steyern P, "Fracture strength of two oxide ceramic crown systems after cyclic pre-loading and thermocycling", J Oral Rehabil, 33, pp.682~689 (2006)
- Tinschert J, "Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics", J Dent, 28, pp.529~535 (2000)
- International Organization for standardization, "ISO 6872:2008, Dental ceramic", ISO, ~ (2008)
- Aboushelib MN, "Microtensile bond strength of different components of core veneered all-ceramic restorations", Dent Mater, 21, pp.984~991 (2005)
- Aboushelib MN, "Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: Zirconia veneering ceramics", Dent Mater, 22, pp.857~863 (2006)
- Beuer F, "Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)", Clin Oral Investig, 13, pp.445~451 (2009)
- Sailer I, "Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up", Quintessence Int, 37, pp.685~693 (2006)
- Vult von Steyern P, "All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study", J Oral Rehabil, 32, pp.180~187 (2005)
- Strub JR, "Causes of failure following oral rehabilitation: biological versus technical factors", Quintessence Int, 19, pp.215~222 (1988)
- Bindl A, "Strength and fracture pattern of monolithic CAD", CAM-generated posterior crowns, 2006, pp.22, 29~36
- Bindl A, "Thin-wall ceramic CAD", CAM crown copings: strength and fracture pattern, 2006, pp.33, 520~528
- Bindl A, "Survival rate of mono-ceramic and ceramic- core CAD", CAM-generated anterior crowns over 2-5 years, 2004, pp.112, 197~204
- Tinschert J, "Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations", J Biomed Mater Res B Appl Biomater, 80, pp.317~321 (2007)
- Witkowski S, "Marginal accuracy of titanium copings fabricated by casting and CAD", CAM techniques, 2006, pp.96, 47~52
- Proussaefs P., "Crowns cemented on crown preparations lacking geometric resistance form. Part II: effect of cement", J Prosthodont, 13, pp.36~41 (2004)
- Smith TB, "In vitro fracture behavior of ceramic and metal-ceramic restorations", J Prosthodont, 3, pp.138~144 (1994)
- Sundh A, "Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing", Dent Mater, 21, pp.476~482 (2005)
- Potiket N, "In vitro fracture strength of teeth restored with different all-ceramic crown systems", J Prosthet Dent, 92, pp.491~495 (2004)
- Komine F, "Current status of zirconia-based fixed restorations", J Oral Sci, 52, pp.531~539 (2010)
- Preis V, "In vitro failure and fracture resistance of veneered and full-contour zirconia restorations", J Dent (2012)
- Beuer F, "High-strength CAD", CAM-fabricated veneering material sintered to zirconia copings-a new fabrication mode for all-ceramic restorations, 2009, pp.25, 121~128
- Scherrer SS, "The fracture resistance of all-ceramic crowns on supporting structures with different elastic moduli", Int J Prosthodont, 6, pp.462~467 (1993)
- Rosentritt M, "In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth", Int J Prosthodont, 13, pp.387~391 (2000)
- Kelly JR, "Clinically relevant approach to failure testing of allceramic restorations", J Prosthet Dent, 81, pp.652~661 (1999)
- Ritter JE, "Predicting lifetimes of materials and material structures", Dent Mater, 11, pp.142~146 (1995)
- Tsalouchou E, "Fatigue and fracture properties of yttria partially stabilized zirconia crown systems", Dent Mater, 24, pp.308~318 (2008)
- Kelly JR, "Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling", J Dent Res, 74, pp.1253~1258 (1995)
- Raigrodski AJ, "The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study", J Prosthet Dent, 96, pp.237~244 (2006)
- Sailer I, "Five-year clinical results of zirconia frameworks for posterior fixed partial dentures", Int J Prosthodont, 20, pp.383~388 (2007)
- Snyder MD, "Load-to-fracture value of different all-ceramic crown systems", J Contemp Dent Pract, 6, pp.54~63 (2005)
- Beuer F, "In vitro performance of full-contour zirconia single crowns", Dent Mater, 28, pp.449~456 (2012)
- 박현순, "Influence of porcelain veneering on the marginal fit of Digident and Lava CAD", CAM zirconia ceramic crowns, 2010, pp.2(2), 33~38[DOI]
- Vinay Chila Bachhav, "The effect of ceramic thickness and number of firings on the color of a zirconium oxide based all ceramic system fabricated using CAD", CAM technology, 2011, pp.3(2), 57~62[DOI]
