본문 바로가기
KERD
논문KCI 등재

Biaxial flexural strength of bilayered zirconia using various veneering ceramics

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. The aim of this study was to evaluate the biaxial flexural strength (BFS) of one zirconia-based ceramic used with various veneering ceramics. MATERIALS AND METHODS. Zirconia core material (Katana) and five veneering ceramics (Cerabien ZR; CZR, Lava Ceram; LV, Cercon Ceram Kiss; CC, IPS e.max Ceram; EM and VITA VM9; VT) were selected. Using the powder/liquid layering technique, bilayered disk specimens (diameter: 12.50 mm, thickness: 1.50 mm) were prepared to follow ISO standard 6872:2008 into five groups according to veneering ceramics as follows; Katana zirconia veneering with CZR (K/CZR), Katana zirconia veneering with LV (K/LV), Katana zirconia veneering with CC (K/CC), Katana zirconia veneering with EM (K/EM) and Katana zirconia veneering with VT (K/VT). After 20,000 thermocycling, load tests were conducted using a universal testing machine (Instron). The BFS were calculated and analyzed with one-way ANOVA and Tukey HSD (α=0.05). The Weibull analysis was performed for reliability of strength. The mode of fracture and fractured surface were observed by SEM. RESULTS. It showed that K/CC had significantly the highest BFS, followed by K/LV. BFS of K/CZR, K/EM and K/VT were not significantly different from each other, but were significantly lower than the other two groups. Weibull distribution reported the same trend of reliability as the BFS results. CONCLUSION. From the result of this study, the BFS of the bilayered zirconia/veneer composite did not only depend on the Young’ modulus value of the materials. Further studies regarding interfacial strength and sintering factors are necessary to achieve the optimal strength.

Abstract

PURPOSE. The aim of this study was to evaluate the biaxial flexural strength (BFS) of one zirconia-based ceramic used with various veneering ceramics. MATERIALS AND METHODS. Zirconia core material (Katana) and five veneering ceramics (Cerabien ZR; CZR, Lava Ceram; LV, Cercon Ceram Kiss; CC, IPS e.max Ceram; EM and VITA VM9; VT) were selected. Using the powder/liquid layering technique, bilayered disk specimens (diameter: 12.50 mm, thickness: 1.50 mm) were prepared to follow ISO standard 6872:2008 into five groups according to veneering ceramics as follows; Katana zirconia veneering with CZR (K/CZR), Katana zirconia veneering with LV (K/LV), Katana zirconia veneering with CC (K/CC), Katana zirconia veneering with EM (K/EM) and Katana zirconia veneering with VT (K/VT). After 20,000 thermocycling, load tests were conducted using a universal testing machine (Instron). The BFS were calculated and analyzed with one-way ANOVA and Tukey HSD (α=0.05). The Weibull analysis was performed for reliability of strength. The mode of fracture and fractured surface were observed by SEM. RESULTS. It showed that K/CC had significantly the highest BFS, followed by K/LV. BFS of K/CZR, K/EM and K/VT were not significantly different from each other, but were significantly lower than the other two groups. Weibull distribution reported the same trend of reliability as the BFS results. CONCLUSION. From the result of this study, the BFS of the bilayered zirconia/veneer composite did not only depend on the Young’ modulus value of the materials. Further studies regarding interfacial strength and sintering factors are necessary to achieve the optimal strength.

참고문헌 (50)

  1. Kelly JR, "Dental ceramics: what is this stuff anyway?", J Am Dent Assoc, 139, pp.4S~7S (2008)
  2. Baldassarri M, "Residual stresses in porcelain-veneered zirconia prostheses", Dent Mater, 28, pp.873~879 (2012)
  3. Salimee P, "Biaxial flexural strength of zirconia-based ceramic with different core: veneer ratio", CU Dent J, 34, pp.75~86 (2011)
  4. Piconi C, "Zirconia as a ceramic biomaterial", Biomaterials, 20, pp.1~25 (1999)
  5. Denry I, "State of the art of zirconia for dental applications", Dent Mater, 24, pp.299~307 (2008)
  6. Larsson C, "The clinical success of zirconiabased crowns: a systematic review", Int J Prosthodont, 27, pp.33~43 (2014)
  7. Håff A, "A retrospective evaluation of zirconia-fixed partial dentures in general practices: an up to 13-year study", Dent Mater, 31, pp.162~170 (2015)
  8. Schmitter M, "Clinical performance of long-span zirconia frameworks for fixed dental prostheses: 5-year results", J Oral Rehabil, 39, pp.552~557 (2012)
  9. Raigrodski AJ, "Survival and complications of zirconia-based fixed dental prostheses:a systematic review", J Prosthet Dent, 107, pp.170~177 (2012)
  10. Kelly JR, "Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling", J Dent Res, 74, pp.1253~1258 (1995)
  11. Beuer F, "High-strength CAD", CAM-fabricated veneering material sintered to zirconia copings-a new fabrication mode for all-ceramic restorations, 2009, pp.25, 121~128
  12. Fischer J, "Flexural strength of veneering ceramics for zirconia", J Dent, 36, pp.316~321 (2008)
  13. Fazi G, "Microtensile bond strength of three different veneering porcelain systems to a zirconia core for all ceramic restorations", Am J Dent, 23, pp.347~350 (2010)
  14. Aboushelib MN, "Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: Zirconia veneering ceramics", Dent Mater, 22, pp.857~863 (2006)
  15. Blatz MB, "Bond strength of different veneering ceramics to zirconia and their susceptibility to thermocycling", Am J Dent, 23, pp.213~216 (2010)
  16. Ozkurt Z, "In vitro evaluation of shear bond strength of veneering ceramics to zirconia", Dent Mater J, 29, pp.138~146 (2010)
  17. Fischer J, "The effect of thermal cycling on metal-ceramic bond strength", J Dent, 37, pp.549~553 (2009)
  18. "ISO 6872:2008. Dentistry-ceramic materials", ISO, ~ (2008)
  19. Lin WS, "The effect of core material, veneering porcelain, and fabrication technique on the biaxial flexural strength and weibull analysis of selected dental ceramics", J Prosthodont, 21, pp.353~362 (2012)
  20. Fleming GJ, "The effect of core:dentin thickness ratio on the bi-axial flexure strength and fracture mode and origin of bilayered dental ceramic composites", Dent Mater, 21, pp.164~171 (2005)
  21. Quinn JB, "A practical and systematic review of Weibull statistics for reporting strengths of dental materials", Dent Mater, 26, pp.135~147 (2010)
  22. Guazzato M, "Strength, reliability and mode of fracture of bilayered porcelain", zirconia (Y-TZP) dental ceramics, 2004, pp.25, 5045~5052
  23. Fischer J, "Impact of thermal misfit on shear strength of veneering ceramic", zirconia composites, 2009, pp.25, 419~423
  24. Swain MV, "Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures", Acta Biomater, 5, pp.1668~1677 (2009)
  25. Komine F, "Effect of cooling rate on shear bond strength of veneering porcelain to a zirconia ceramic material", J Oral Sci, 52, pp.647~652 (2010)
  26. Tuccillo JJ, "Shear stress measurements at a dental porcelain-gold bond interface", J Dent Res, 51, pp.626~633 (1972)
  27. Saito A, "A comparison of bond strength of layered veneering porcelains to zirconia and metal", J Prosthet Dent, 104, pp.247~257 (2010)
  28. De Jager N, "The influence of design parameters on the FEA-determined stress distribution in CADCAM produced all-ceramic dental crowns", Dent Mater, 21, pp.242~251 (2005)
  29. Papanagiotou HP, "In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics", J Prosthet Dent, 96, pp.154~164 (2006)
  30. White SN, "Flexural strength of a layered zirconia and porcelain dental all-ceramic system", J Prosthet Dent, 94, pp.125~131 (2005)
  31. Zeng K, "Evaluation of mechanical properties of dental ceramic core materials in combination with porcelains", Int J Prosthodont, 11, pp.183~189 (1998)
  32. Thompson GA, "Influence of relative layer height and testing method on the failure mode and origin in a bilayered dental ceramic composite", Dent Mater, 16, pp.235~243 (2000)
  33. Taskonak B, "Residual stresses in bilayer dental ceramics", Biomaterials, 26, pp.3235~3241 (2005)
  34. Aboushelib MN, "Microtensile bond strength of different components of core veneered all-ceramic restorations", Dent Mater, 21, pp.984~991 (2005)
  35. Isgrò G, "The effects of thermal mismatch and fabrication procedures on the deflection of layered all-ceramic discs", Dent Mater, 21, pp.649~655 (2005)
  36. Yoshinari M, "Fracture strength of all-ceramic crowns", Int J Prosthodont, 7, pp.329~338 (1994)
  37. Studart AR, "In vitro lifetime of dental ceramics under cyclic loading in water", Biomaterials, 28, pp.2695~2705 (2007)
  38. Ohlmann B, "All-ceramic inlay-retained fixed partial dentures:preliminary results from a clinical study", J Dent, 36, pp.692~696 (2008)
  39. Anusavice KJ, "Which mechanical and physical testing methods are relevant for predicting the clinical performance of ceramic-based dental prostheses?", Clin Oral Implants Res, 18, pp.218~231 (2007)
  40. Ban S, "Influence of test method on failure stress of brittle dental materials", J Dent Res, 69, pp.1791~1799 (1990)
  41. Lawn BR, "Use of contact testing in the characterization and design of all-ceramic crownlike layer structures: a review", J Prosthet Dent, 86, pp.495~510 (2001)
  42. Aboushelib MN, "Effect of zirconia type on its bond strength with different veneer ceramics", J Prosthodont, 17, pp.401~408 (2008)
  43. Kim HJ, "Effect of zirconia surface treatments on the shear bond strength of veneering ceramic", J Prosthet Dent, 105, pp.315~322 (2011)
  44. Wiskott HW, "Stress fatigue: basic principles and prosthodontic implications", Int J Prosthodont, 8, pp.105~116 (1995)
  45. Zhang Y, "Long-term strength of ceramics for biomedical applications", J Biomed Mater Res B Appl Biomater, 69, pp.166~172 (2004)
  46. Wakabayashi N, "Crack initiation modes in bilayered alumina", porcelain disks as a function of core, J Dent Res, pp.2000, 79[DOI]
  47. Miyazaki T, "Current status of zirconia restoration", J Prosthodont Res, 57, pp.236~261 (2013)
  48. Al-Amleh B, "Influenc of veneering porcelain thickness and cooling rate on residual stresses in zirconia molar crowns", Dent Mater, 30, pp.271~280 (2014)
  49. Paula VG, "Slow cooling protocol improves fatigue life of zirconia crowns", Dent Mater, 31, pp.77~87 (2015)
  50. Belli R, "Thermal-induced residual stresses affect the lifetime of zirconia-veneer crowns", Dent Mater, 29, pp.181.e~190.e (2013)

관련 논문AI추천

이 간행물의 다른 논문 (9건)