본문 바로가기
KERD
논문KCI 등재

Perceived color shift of ceramics according to the change of illuminating light with spectroradiometer

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. Perceived color of ceramics changes by the spectral power distribution of ambient light. This study aimed to quantify the amount of shifts in color and color coordinates of clinically simulated seven all-ceramics due to the switch of three ambient light sources using a human vision simulating spectroradiometer. MATERIALS AND METHODS. CIE color coordinates, such as L*, a* and b*,of ceramic specimens were measured under three light sources, which simulate the CIE standard illuminant D65 (daylight), A (incandescent lamp), and F9 (fluorescent lamp). Shifts in color and color coordinate by the switch of lights were determined. Influence of the switched light (D65 to A, or D65 to F9), shade of veneer ceramics (A2 or A3), and brand of ceramics on the shifts was analyzed by a three-way ANOVA. RESULTS. Shifts in color and color coordinates were influenced by three factors (P<.05). Color shifts by the switch to A were in the range of 5.9 to 7.7 ΔE*abunits, and those by the switch to F9 were 7.7 to 10.2; all of which were unacceptable (ΔE*ab > 5.5). When switched to A, CIE a* increased (Δa*: 5.6 to 7.6), however, CIE b* increased (Δb*: 4.9 to 7.8) when switched to F9. CONCLUSION. Clinically simulated ceramics demonstrated clinically unacceptable color shifts according to the switches in ambient lights based on spectroradiometric readings. Therefore, shade matching and compatibility evaluation should be performed considering ambient lighting conditions and should be done under most relevant lighting condition.

Abstract

PURPOSE. Perceived color of ceramics changes by the spectral power distribution of ambient light. This study aimed to quantify the amount of shifts in color and color coordinates of clinically simulated seven all-ceramics due to the switch of three ambient light sources using a human vision simulating spectroradiometer. MATERIALS AND METHODS. CIE color coordinates, such as L*, a* and b*,of ceramic specimens were measured under three light sources, which simulate the CIE standard illuminant D65 (daylight), A (incandescent lamp), and F9 (fluorescent lamp). Shifts in color and color coordinate by the switch of lights were determined. Influence of the switched light (D65 to A, or D65 to F9), shade of veneer ceramics (A2 or A3), and brand of ceramics on the shifts was analyzed by a three-way ANOVA. RESULTS. Shifts in color and color coordinates were influenced by three factors (P<.05). Color shifts by the switch to A were in the range of 5.9 to 7.7 ΔE*abunits, and those by the switch to F9 were 7.7 to 10.2; all of which were unacceptable (ΔE*ab > 5.5). When switched to A, CIE a* increased (Δa*: 5.6 to 7.6), however, CIE b* increased (Δb*: 4.9 to 7.8) when switched to F9. CONCLUSION. Clinically simulated ceramics demonstrated clinically unacceptable color shifts according to the switches in ambient lights based on spectroradiometric readings. Therefore, shade matching and compatibility evaluation should be performed considering ambient lighting conditions and should be done under most relevant lighting condition.

참고문헌 (44)

  1. Vichi A, "Color related to ceramic and zirconia restorations: a review", Dent Mater, 27, pp.97~108 (2011)
  2. Barão VA, "Factors to achieve aesthetics in all-ceramic restorations", J Craniofac Surg, 21, pp.2007~2012 (2010)
  3. Lee YK, "Perceived color shift of a shade guide according to the change of illuminant", J Prosthet Dent, 105, pp.91~99 (2011)
  4. Rosenstiel SF, "Contemporary fixed prothodontics", pp.774~ (2006), Mosby
  5. Anusavice K, "Philips’' science of dental materials", pp.655~719 (2003), Saunders
  6. Zhang Y, "Graded zirconia glass for resistance to veneer fracture", J Dent Res, 89, pp.1057~1062 (2010)
  7. Barnes D, "Clinical evaluation of an all-ceramic restorative system: a 36-month clinical evaluation", Am J Dent, 23, pp.87~92 (2010)
  8. Park JH, "Influence of illuminants on the color distribution of shade guides", J Prosthet Dent, 96, pp.402~411 (2006)
  9. Judeh A, "A comparison between conventional visual and spectrophotometric methods for shade selection", Quintessence Int, 40, pp.69~79 (2009), Quintessence Int
  10. Lehmann KM, "Four color-measuring devices compared with a spectrophotometric reference system", J Dent, 38(2), pp.65~70 (2010)
  11. Ishikawa-Nagai S, "Spectrophotometric analysis of tooth color reproduction on anterior all-ceramic crowns: Part 1: analysis and interpretation of tooth color", J Esthet Restor Dent, 22, pp.42~52 (2010)
  12. Johnston WM, "Analysis of edge-losses in reflectance measurements of pigmented maxillofacial elastomer", J Dent Res, 75, pp.752~760 (1996)
  13. Yap AU, "Human-eye versus computerized color matching", Oper Dent, 24, pp.358~363 (1999)
  14. Wyszecki G, "Color science - Concepts and methods, quantitative data and formulae" (2000), John Wiley and Sons
  15. Marcus RT, "The measurement of color, In Color for science, art and technology", pp.48~49 (1998), Elsevier
  16. Lee YK, "Color characteristics of low-chroma and high-translucence dental resin composites by different measuring modes", J Biomed Mater Res, 58, pp.613~621 (2001)
  17. Lee YK, "Color difference of four esthetic restorative materials by the illuminant", Am J Dent, 18, pp.359~363 (2005)
  18. Yu B, "Color difference of all-ceramic materials by the change of illuminants", Am J Dent, 22, pp.73~78 (2009)
  19. van der Burgt TP, "A new method for matching tooth colors with color standards", J Dent Res, 64, pp.837~841 (1985)
  20. Lee YK, "Effects of colour measuring mode and light source on the colour of shade guides", J Oral Rehabil, 29, pp.1099~1107 (2002)
  21. Kim SH, "Metameric effect between dental porcelain and porcelain repairing resin composite", Dent Mater, 23, pp.374~379 (2007)
  22. Volpato CA, "Optical influence of the type of illuminant, substrates and thickness of ceramic materials", Dent Mater, 25, pp.87~93 (2009)
  23. Corcodel N, "Metameric effect between natural teeth and the shade tabs of a shade guide", Eur J Oral Sci, 118, pp.311~316 (2010)
  24. Cha HS, "Difference in illuminant-dependent color changes of shade guide tabs by the shade designation relative to three illuminants", Am J Dent, 22, pp.350~356 (2009)
  25. Gokce HS, "Shade matching performance of normal and color vision-deficient dental professionals with standard daylight and tungsten illuminants", J Prosthet Dent, 103, pp.139~147 (2010)
  26. Carsten DL, "Successful shade matching--what does it take", Compend Contin Educ Dent, 24, pp.175~182 (2003)
  27. Commission Internationale de l’'Eclairage (CIE) Colorimetry-technical report, , Bureau Central de la CIE, ~, pp.CIE Pub. No. 15 (2004)
  28. Lee YK, "Variation in instrument-based color coordinates of esthetic restorative materials by measurement method-A review", Dent Mater, 26, pp.1098~1105 (2010)
  29. van der Burgt TP, "A comparison of new and conventional methods for quantification of tooth color", J Prosthet Dent, 63, pp.155~162 (1990)
  30. Bolt RA, "Influence of window size in small-window color measurements, particularly of teeth", Phys Med Biol, 39, pp.1133~1142 (1994)
  31. Lee YK, "Layered color of all-ceramic core and veneer ceramics", J Prosthet Dent, 97, pp.279~286 (2007)
  32. Gozalo-Diaz D, "Estimating the color of maxillary central incisors based on age and gender", J Prosthet Dent, 100, pp.93~98 (2008)
  33. Bayindir F, "Coverage error of gingival shade guide systems in measuring color of attached anterior gingiva", J Prosthet Dent, 101, pp.46~53 (2009)
  34. Li Q, "In vivo spectroradiometric evaluation of colour matching errors among five shade guides", J Oral Rehabil, 36, pp.65~70 (2009)
  35. Ghinea R, "Color difference thresholds in dental ceramics", J Dent, 38(2), pp.57~64 (2010)
  36. Douglas RD, "Intraoral determination of the tolerance of dentists for perceptibility and acceptability of shade mismatch", J Prosthet Dent, 97, pp.200~208 (2007)
  37. Davis S, "Color perception - philosophical, psychological, artistic, and cognitive perspectives", pp.88~90 (2000), Oxford University Press
  38. O’'Brien WJ, "One-dimensional color order system for dental shade guides", Dent Mater, 5, pp.371~374 (1989)
  39. Ferreira D, "Measurement of spectral reflectance and colorimetric properties of Vita shade guides", J Dent Assoc S Afr, 46, pp.63~65 (1991)
  40. Lee YK, "Metameric effect between resin composite and dentin", Dent Mater, 2, pp.971~976 (2005)
  41. Heffernan MJ, "Relative translucency of six all-ceramic systems. Part I: core materials", J Prosthet Dent, 88, pp.4~9 (2002)
  42. Paravina RD, "Color interaction of dental materials: blending effect of layered composites", Dent Mater, 22, pp.903~908 (2006)
  43. Lee YK, "Lightness, chroma, and hue distributions of a shade guide as measured by a spectroradiometer", J Prosthet Dent, 104, pp.173~181 (2010)
  44. Kim JG, "Correlations between color differences based on three color-difference formulas using dental shade guide tabs", J Prosthodont, 18, pp.135~140 (2009)

관련 논문AI추천

이 간행물의 다른 논문 (19건)