본문 바로가기
KERD
논문KCI 등재

Effect of the amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics

2

조회

0

다운로드

8

인용

0

참고문헌

키워드

초록

PURPOSE. This study investigated the effect of amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics. MATERIALS AND METHODS. One-hundred sixty-five monolithic zirconia specimens (16.3 mm × 16.3 mm × 2.0 mm) were divided into 5 groups (Group I to V) according to the number of A2-coloring liquid applications. Each group was then divided into 11 subgroups by reducing the thickness up to 1.0 mm in 0.1-mm increments (Subgroup 0 to 10, n=3). Colors and spectral distributions were measured according to CIELAB on a reflection spectrophotometer. All measurements were performed on five different areas of each specimen. Color difference (ΔE* ab) and translucency parameter (TP) were calculated. Data were analyzed using one-way ANOVA and multiple comparison Scheffé test (α=.05). RESULTS. There were significant differences in CIE L* between Subgroup 0 and other subgroups in all groups. CIE a* increased (0.52<R2<0.73), while CIE b* decreased (0.00<R2<0.74) in all groups with increasing thickness reduction. Perceptible color differences (ΔE*ab>3.7) were obtained between Subgroup 0 and other subgroups. TP values generally increased as the thickness reduction increased in all groups (R2>0.89, P<.001). CONCLUSION. Increasing thickness reduction reduces lightness and increases a reddish, bluish appearance, and translucency of monolithic zirconia ceramics.

Abstract

PURPOSE. This study investigated the effect of amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics. MATERIALS AND METHODS. One-hundred sixty-five monolithic zirconia specimens (16.3 mm × 16.3 mm × 2.0 mm) were divided into 5 groups (Group I to V) according to the number of A2-coloring liquid applications. Each group was then divided into 11 subgroups by reducing the thickness up to 1.0 mm in 0.1-mm increments (Subgroup 0 to 10, n=3). Colors and spectral distributions were measured according to CIELAB on a reflection spectrophotometer. All measurements were performed on five different areas of each specimen. Color difference (ΔE* ab) and translucency parameter (TP) were calculated. Data were analyzed using one-way ANOVA and multiple comparison Scheffé test (α=.05). RESULTS. There were significant differences in CIE L* between Subgroup 0 and other subgroups in all groups. CIE a* increased (0.52<R2<0.73), while CIE b* decreased (0.00<R2<0.74) in all groups with increasing thickness reduction. Perceptible color differences (ΔE*ab>3.7) were obtained between Subgroup 0 and other subgroups. TP values generally increased as the thickness reduction increased in all groups (R2>0.89, P<.001). CONCLUSION. Increasing thickness reduction reduces lightness and increases a reddish, bluish appearance, and translucency of monolithic zirconia ceramics.

참고문헌 (28)

  1. McLean JW, "Evolution of dental ceramics in the twentieth century", J Prosthet Dent, 85, pp.61~66 (2001)
  2. Douglas RD, "Predicting porcelain thickness required for dental shade matches", J Prosthet Dent, 82, pp.143~149 (1999)
  3. Isgrò G, "The influence of the veneering porcelain and different surface treatments on the biaxial flexural strength of a heat-pressed ceramic", J Prosthet Dent, 90, pp.465~473 (2003)
  4. Tinschert J, "Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: A laboratory study", Int J Prosthodont, 14, pp.231~238 (2001)
  5. Al-Amleh B, "Clinical trials in zirconia: a systematic review", J Oral Rehabil, 37, pp.641~652 (2010)
  6. 하승룡, "The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study", The Journal of Advanced of Prosthodontics, 5(2), pp.187~197 (2013), 대한치과보철학회[DOI]
  7. 김희경, "Effect of polishing and glazing on the color and spectral distribution of monolithic zirconia", The Journal of Advanced of Prosthodontics, 5(3), pp.296~304 (2013), 대한치과보철학회[DOI]
  8. de Azevedo Cubas G B, "The effect of luting agents and ceramic thickness on the color variation of different ceramics against a chromatic background", Eur J Dent, 5, pp.245~252 (2011)
  9. Vichi A, "Influence of ceramic and cement thickness on the masking of various types of opaque posts", J Prosthet Dent, 83, pp.412~417 (2000)
  10. Shokry TE, "Effect of core and veneer thicknesses on the color parameters of two all-ceramic systems", J Prosthet Dent, 95, pp.124~129 (2006)
  11. Dozic A, "The influence of porcelain layer thickness on the final shade of ceramic restorations", J Prosthet Dent, 90, pp.563~570 (2003)
  12. Terada Y, "The influence of different thicknesses of dentin porcelain on the color reflected from thin opaque porcelain fused to metal", Int J Prosthodont, 2, pp.352~356 (1989)
  13. Ozturk O, "The effect of ceramic thickness and number of firings on the color of two all-ceramic systems", J Prosthet Dent, 100, pp.99~106 (2008)
  14. Antonson SA, "Contrast ratio of veneering and core ceramics as a function of thickness", Int J Prosthodont, 14, pp.316~320 (2001)
  15. Lund PS, "Evaluation of the color and appearance of a new textured opaque porcelain", Int J Prosthodont, 4, pp.548~554 (1991)
  16. Kim HK, "Effect of the number of coloring liquid applications on the optical properties of monolithic zirconia", Dent Mater, 30, pp.e229~e237 (2014)
  17. Commission Internationale de l’Eclairage, "Colorimetry", CIE Central Bureau, ~ (2004)
  18. Johnston WM, "Translucency parameter of colorants for maxillofacial prostheses", Int J Prosthodont, 8, pp.79~86 (1995)
  19. Johnston WM, "Assessment of appearance match by visual observation and clinical colorimetry", J Dent Res, 68(5), pp.819~822
  20. Jorgenson MW, "Spectrophotometric study of five porcelain shades relative to the dimensions of color, porcelain thickness, and repeated firings", J Prosthet Dent, 42, pp.96~105 (1979)
  21. Jacobs SH, "Effect of porcelain thickness and type of metal-ceramic alloy on color", J Prosthet Dent, 57, pp.138~145 (1987)
  22. Judd DB, "Color in business, science and industry", pp.397~417 (1975), John Wiley & Sons
  23. Douglas RD, "Acceptability of shade differences in metal ceramic crowns", J Prosthet Dent, 79, pp.254~260 (1998)
  24. Heffernan MJ, "Relative translucency of six all-ceramic systems. Part I: Core materials", J Prosthet Dent, 88, pp.4~9 (2002)
  25. Heffernan MJ, "Relative translucency of six all-ceramic systems. Part II: Core and veneer materials", J Prosthet Dent, 88, pp.10~15 (2002)
  26. O’Keefe KL, "Variables affecting the spectral transmittance of light through porcelain veneer samples", J Prosthet Dent, 66, pp.434~438 (1991)
  27. Nassau K, "The physics and chemistry of color", pp.231~236 (2001), John Wiley & Sons
  28. Kingery WD, "Introduction to ceramic", pp.668~ (1976), John Wiley & Sons

관련 논문AI추천

이 간행물의 다른 논문 (9건)